Mechanically Interlocked Hydrogel–Elastomer Strain Sensor with Robust Interface and Enhanced Water—Retention Capacity

Wenyu Zhao, Zhuofan Lin, Xiaopu Wang, Ziya Wang, Zhenglong SunGels 2022 · DOI

TL;DR

This paper presents a novel hydrogel-elastomer hybrid strain sensor that overcomes the critical dehydration issue of hydrogels. By employing a porous thermoplastic polyurethane (TPU) interlayer, they achieve robust mechanical interlocking and strong adhesion between the hydrogel and a hydrophobic polydimethylsiloxane (PDMS) encapsulation layer, resulting in excellent water retention and a highly sensitive, durable strain sensor.

What Problem Does This Paper Address?

Wearable strain sensors based on hydrogels offer promising flexibility and biocompatibility, mimicking the mechanical properties of human skin. However, a major hurdle for their practical application is their susceptibility to dehydration when exposed to ambient air. This water loss leads to a decline in mechanical properties and electrical conductivity, severely limiting their service life and reliability. Existing solutions, such as incorporating humectants like glycerol, often compromise the hydrogel's mechanical strength and conductivity. Encapsulation with hydrophobic polymers offers a barrier against water evaporation, but achieving strong, stable adhesion between the hydrophilic hydrogel and hydrophobic elastomer has been a persistent challenge, often leading to interface delamination under strain. This paper aims to address this by developing a robust and general method for creating a strong interface that simultaneously enhances water retention and maintains the sensor's performance.

Methods

The core innovation lies in the interface engineering between the hydrogel and the encapsulating elastomer. The authors propose a three-layer structure:

  1. Hydrogel Core: A PVA-based ionic hydrogel (PVA-G-FeCl₃) was synthesized, incorporating glycerol (G) for improved water retention and FeCl₃ as an electrolyte to enhance ionic conductivity.
  2. Interlocking Interlayer: A porous thermoplastic polyurethane (TPU) layer was fabricated using a sacrificial template method (NaCl particles). This porous structure serves as a mechanical anchor.
  3. Encapsulating Elastomer: Polydimethylsiloxane (PDMS), a common hydrophobic elastomer, was used to encapsulate the hydrogel.

The fabrication process involves:

  • Creating a porous TPU layer by mixing TPU with NaCl particles, molding, heating, and then removing the NaCl via immersion in water.
  • Bonding the porous TPU to uncured PDMS by heating, allowing the PDMS to partially infiltrate the TPU pores.
  • Applying the hydrogel solution onto the TPU layer, allowing it to soak into the pores.
  • Frozen crosslinking of the hydrogel, which mechanically interlocks it with the porous TPU structure.

This "mechanically interlocked" interface, combined with the hydrophobic PDMS barrier, is key to achieving both strong adhesion and water retention. The authors also characterized the mechanical properties (tensile tests, interfacial toughness via 90° peeling tests), electrical conductivity, and strain sensing performance (gauge factor) of their developed hydrogel-elastomer hybrid strain sensor (IHSS).

Datasets

Not discussed in the paper. The study focuses on the material development and characterization of a novel sensor, rather than training on large datasets.

Key Insights and Ideas

  • The Power of Mechanical Interlocking: The porous TPU interlayer acts as a "zipper," physically interlocking the hydrogel and bonding the PDMS. This mechanical connection is crucial for overcoming the inherent poor adhesion between hydrophilic hydrogels and hydrophobic elastomers, leading to significantly enhanced interfacial toughness.
  • Synergistic Water Retention: The hydrophobic PDMS layer acts as a primary barrier against water evaporation, while the glycerol within the hydrogel contributes to maintaining moisture. This dual approach leads to a substantial improvement in water retention compared to unencapsulated hydrogels.
  • Generalizable Interface Strategy: The use of a porous structured TPU as an adhesive and interlocking agent is presented as a simple and general strategy, suggesting its potential applicability to other hydrogel-elastomer combinations.
  • Balancing Properties: The study demonstrates how to tune the hydrogel composition (glycerol content, FeCl₃ concentration) and the PDMS crosslinking ratio to achieve a balance of water retention, mechanical strength, ionic conductivity, and strain sensitivity.

Key Results

  • Water Retention: The PDMS-encapsulated hydrogels showed significantly reduced weight loss (minor drift of about 5% in 24 hours) compared to unencapsulated hydrogels, which lost almost all moisture within 24 hours. Even after 21 days, encapsulated hydrogels retained substantial moisture.
  • Interfacial Toughness: The proposed method achieved a robust interface with interfacial toughness exceeding 1200 J/m², which is significantly higher than typical hydrogel-elastomer interfaces. The peeling tests showed cohesive failure within the hydrogel, indicating the interface was stronger than the hydrogel itself.
  • Mechanical Properties: The PVA10-G30 hydrogel exhibited high tensile strength (95.52 kPa) and elongation at break (300%). The PDMS modulus could be tuned by adjusting the crosslinker-to-monomer ratio, allowing for better modulus matching with the hydrogel.
  • Strain Sensing Performance: The IHSS demonstrated a highly linear sensitivity with a gauge factor (GF) of 2.21 at 100% strain. The sensor showed good cyclic stability and repeatability.
  • Human Motion Monitoring: The IHSS successfully monitored various human motions, including facial expressions (frowning), breathing, radial artery pulse, speech recognition, and joint movements (finger, elbow, knee bending), as well as foot movements during walking and running.

Limitations and Future Work

  • Temperature Dependence: While the encapsulated hydrogels showed improved temperature resistance compared to unencapsulated ones, the paper notes that almost all hydrogels struggle with long-term stability at high temperatures. Further work could explore more advanced encapsulation strategies or hydrogel compositions for extreme temperature environments.
  • Long-term Stability: Although the water retention is significantly improved, the long-term stability of the hydrogel-elastomer interface under continuous mechanical stress and varying environmental conditions could be further investigated.
  • Optimization of Interlayer: While the porous TPU interlayer is effective, exploring alternative porous materials or fabrication methods for the interlayer could potentially lead to further improvements in adhesion and mechanical properties.
  • Broader Applications: The authors suggest the practicability and effectiveness of their approach for advanced ionic electronics and valuable applications in human-motion monitoring. Future work could focus on integrating these sensors into more complex wearable systems and exploring their use in medical diagnostics and rehabilitation.

Summary updated

Abstract

Hydrogels are stretchable ion conductors that can be used as strain sensors by transmitting strain-dependent electrical signals. However, hydrogels are susceptible to dehydration in the air, leading to a loss of flexibility and functions. Here, a simple and general strategy for encapsulating hydrogel with hydrophobic elastomer is proposed to realize excellent water-retention capacity. Elastomers, such as polydimethylsiloxanes (PDMS), whose hydrophobicity and dense crosslinking network can act as a barrier against water evaporation (lost 4.6 wt.% ± 0.57 in 24 h, 28 °C, and ≈30% humidity). To achieve strong adhesion between the hydrogel and elastomer, a porous structured thermoplastic polyurethane (TPU) is used at the hydrogel-elastomer interface to interlock the hydrogel and bond the elastomer simultaneously (the maximum interfacial toughness is over 1200 J/m<sup>2</sup>). In addition, a PDMS encapsulated ionic hydrogel strain sensor is proposed, demonstrating an excellent water-retention ability, superior mechanical performance, highly linear sensitivity (gauge factor = 2.21, at 100% strain), and robust interface. Various human motions were monitored, proving the effectiveness and practicability of the hydrogel-elastomer hybrid.
BibTeX
@inproceedings{zhao2022mechanically,
  author = {Wenyu Zhao and Zhuofan Lin and Xiaopu Wang and Ziya Wang and Zhenglong Sun},
  title = {{Mechanically Interlocked Hydrogel–Elastomer Strain Sensor with Robust Interface and Enhanced Water—Retention Capacity}},
  booktitle = {Gels},
  year = {2022},
  doi = {10.3390/gels8100625},
}
Figure