Measurement of the longitudinal diffusion of ionization electrons in the MicroBooNE detector

P. Abratenko, R. An, J. Anthony, J. Asaadi, A. Ashkenazi, S. Balasubramanian, B. Baller, C. Barnes, G. Barr, V. Basque, L. Bathe-Peters, O. Benevides Rodrigues, S. Berkman, A. Bhanderi, A. Bhat, M. Bishai, A. Blake, T. Bolton, L. Camilleri, D. Caratelli, I. Caro Terrazas, R. Castillo Fernández, F. Cavanna, G. B. Cerati, Y. Chen, E. Church, D. Cianci, J. M. Conrad, M. Convery, L. Cooper-Troendle, J. I. Crespo-Anadón, M. Del Tutto, S. R. Dennis, D. Devitt, R. Diurba, R. Dorrill, K. Duffy, S. Dytman, B. Eberly, A. Ereditato, J. J. Evans, R. Fine, G. A. Fiorentini Aguirre, R. S. Fitzpatrick, B. T. Fleming, N. Foppiani, D. Franco, A. P. Furmanski, D. García-Gámez, S. Gardiner, G. Ge, S. Gollapinni, O. Goodwin, E. Gramellini, P. Green, H. Greenlee, Wei Gu, R. Guénette, P. Guzowski, L. Hagaman, E. Hall, P. Hamilton, O. Hen, G. A. Horton-Smith, A. Hourlier, R. Itay, C. James, X. Ji, L. Jiang, J. H. Jo, R. A. Johnson, Y.-j. Jwa, N. Kamp, N. Kaneshige, G. Karagiorgi, W. Ketchum, M. Kirby, T. Kobilarcik, I. Kreslo, R. LaZur, I. Lepetic, K. Li, Yangmu Li, K. Lin, A. Lister, B. R. Littlejohn, W. C. Louis, X. Luo, K. Manivannan, C. Mariani, D. Marsden, J. Marshall, D. A. Martínez Caicedo, K. Mason, A. Mastbaum, N. McConkey, V. Meddage, T. Mettler, K. Miller, J. MillsarXiv 2021 · DOI · arXiv

Abstract

Accurate knowledge of electron transport properties is vital to understanding the information provided by liquid argon time projection chambers (LArTPCs). Ionization electron drift-lifetime, local electric field distortions caused by positive ion accumulation, and electron diffusion can all significantly impact the measured signal waveforms. This paper presents a measurement of the effective longitudinal electron diffusion coefficient, $D_L$, in MicroBooNE at the nominal electric field strength of 273.9 V/cm. Historically, this measurement has been made in LArTPC prototype detectors. This represents the first measurement in a large-scale (85 tonne active volume) LArTPC operating in a neutrino beam. This is the largest dataset ever used for this measurement. Using a sample of ∼70,000 through-going cosmic ray muon tracks tagged with MicroBooNE's cosmic ray tagger system, we measure $D_L = 3.74^{+0.28}_{-0.29} \text{ cm}^2/\text{s}$.

Introduction: The Challenge of Electron Diffusion

In a Liquid Argon Time Projection Chamber (LArTPC), charged particles—such as those produced in neutrino interactions—ionize argon atoms along their path. This creates a cloud of electrons that drifts toward a readout plane under the influence of an electric field. As these electrons travel, the cloud naturally spreads out due to diffusion.

Longitudinal diffusion ($D_L$) specifically refers to the spreading of the electron cloud along the direction of the drift. This process "smears" the resulting signal in time, which can complicate the reconstruction of a particle's energy and position. While $D_L$ has been studied in small-scale laboratory prototypes, there has been a persistent discrepancy between experimental results and theoretical models. Resolving this "tension" is critical for the next generation of giant neutrino experiments, such as DUNE.

Schematic of a LArTPC showing the ionization process, electron drift, and the resulting waveforms on the sense wire planes.

Experimental Methods

The MicroBooNE collaboration utilized a massive dataset of approximately 70,000 cosmic ray muons to perform this measurement. To ensure high precision, the researchers needed to know the exact entry time ($t_0$) of each muon. This was achieved using the Cosmic Ray Tagger (CRT), a system of external scintillating strips that "tags" muons as they enter the detector.

The analysis involved several sophisticated steps:

  1. Track Selection: Identifying long, straight, through-going muon tracks.
  2. Waveform Summation: To overcome noise, the team grouped hits by drift time and aligned hundreds of waveforms to create high-fidelity "representative" pulses for various drift distances.
  3. Linear Fitting: According to transport theory, the squared width of the electron pulse ($\sigma_t^2$) increases linearly with drift time ($t$). By plotting this relationship, the slope of the line yields the diffusion coefficient $D_L$.
  4. 2D Deconvolution: Advanced signal processing was used to isolate the ionization signal from the detector's electronics and field response.
A series of summed waveforms from the Y-plane at different drift times. The broadening of the pulse width as drift time increases is a direct manifestation of longitudinal diffusion.

Key Results and Insights

The measured effective longitudinal diffusion coefficient is $D_L = 3.74^{+0.28}_{-0.29} \text{ cm}^2/\text{s}$ at an electric field of 273.9 V/cm. This result is significant for several reasons:

  • Theory Validation: The data aligns closely with the Atrazhev-Timoshkin theory, favoring it over the previously popular Li et al. parametrization. Many current LArTPC simulations use the Li et al. values, which predict significantly higher diffusion ($6.40 \text{ cm}^2/\text{s}$).
  • Real-World Calibration: This work demonstrates that fundamental microphysics can be extracted from large-scale detectors, accounting for complex "real-world" effects like the Space Charge Effect (local electric field distortions).
  • Compact Signals: The lower measured value suggests that ionization clouds remain more "compact" during their drift than previously assumed in many simulation frameworks.

Conclusion and Future Impact

This measurement provides a vital calibration for future experiments. The Deep Underground Neutrino Experiment (DUNE), for instance, will feature drift distances up to 3.6 meters—significantly longer than MicroBooNE's. Accurate diffusion constants are essential for DUNE's ability to reconstruct complex neutrino interactions.

While this study resolves some of the tension between theory and experiment, it also highlights the need for further research. Future work could involve varying the electric field strength to map the $D_L$ curve more comprehensively and investigating why different detector geometries might yield varying results.

Summary updated

Abstract

Accurate knowledge of electron transport properties is vital to understanding the information provided by liquid argon time projection chambers (LArTPCs). Ionization electron drift-lifetime, local electric field distortions caused by positive ion accumulation, and electron diffusion can all significantly impact the measured signal waveforms. This paper presents a measurement of the effective longitudinal electron diffusion coefficient, DL, in MicroBooNE at the nominal electric field strength of 273.9 V/cm. Historically, this measurement has been made in LArTPC prototype detectors. This represents the first measurement in a large-scale (85 tonne active volume) LArTPC operating in a neutrino beam. This is the largest dataset ever used for this measurement. Using a sample of ∼70,000 through-going cosmic ray muon tracks tagged with MicroBooNE's cosmic ray tagger system, we measure DL = 3.74+0.28 -0.29 cm2/s.
BibTeX
@misc{abratenko2021measurement,
  author = {P. Abratenko and R. An and J. Anthony and J. Asaadi and A. Ashkenazi and S. Balasubramanian and B. Baller and C. Barnes and G. Barr and V. Basque and L. Bathe-Peters and O. Benevides Rodrigues and S. Berkman and A. Bhanderi and A. Bhat and M. Bishai and A. Blake and T. Bolton and L. Camilleri and D. Caratelli and I. Caro Terrazas and R. Castillo Fernández and F. Cavanna and G. B. Cerati and Y. Chen and E. Church and D. Cianci and J. M. Conrad and M. Convery and L. Cooper-Troendle and J. I. Crespo-Anadón and M. Del Tutto and S. R. Dennis and D. Devitt and R. Diurba and R. Dorrill and K. Duffy and S. Dytman and B. Eberly and A. Ereditato and J. J. Evans and R. Fine and G. A. Fiorentini Aguirre and R. S. Fitzpatrick and B. T. Fleming and N. Foppiani and D. Franco and A. P. Furmanski and D. García-Gámez and S. Gardiner and G. Ge and S. Gollapinni and O. Goodwin and E. Gramellini and P. Green and H. Greenlee and Wei Gu and R. Guénette and P. Guzowski and L. Hagaman and E. Hall and P. Hamilton and O. Hen and G. A. Horton-Smith and A. Hourlier and R. Itay and C. James and X. Ji and L. Jiang and J. H. Jo and R. A. Johnson and Y.-J. Jwa and N. Kamp and N. Kaneshige and G. Karagiorgi and W. Ketchum and M. Kirby and T. Kobilarcik and I. Kreslo and R. LaZur and I. Lepetic and K. Li and Yangmu Li and K. Lin and A. Lister and B. R. Littlejohn and W. C. Louis and X. Luo and K. Manivannan and C. Mariani and D. Marsden and J. Marshall and D. A. Martínez Caicedo and K. Mason and A. Mastbaum and N. McConkey and V. Meddage and T. Mettler and K. Miller and J. Mills},
  title = {{Measurement of the longitudinal diffusion of ionization electrons in the MicroBooNE detector}},
  year = {2021},
  eprint = {2104.06551},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2104.06551},
}

Loading related content...

Figure