Measurement of the atmospheric muon rate with the MicroBooNE Liquid Argon TPC

P. Abratenko, M. Alrashed, R. An, J. Anthony, J. Asaadi, A. Ashkenazi, S. Balasubramanian, B. Baller, C. Barnes, G. Barr, V. Basque, M. Bass, L. Bathe-Peters, O. Benevides Rodrigues, S. Berkman, A. Bhanderi, A. Bhat, M. Bishai, A. Blake, T. Bolton, L. Camilleri, D. Caratelli, I. Caro Terrazas, R. Castillo Fernández, F. Cavanna, G. B. Cerati, Y. Chen, E. Church, D. Cianci, J. M. Conrad, M. Convery, L. Cooper-Troendle, J. I. Crespo-Anadón, M. Del Tutto, D. Devitt, R. Diurba, L. Domine, R. Dorrill, K. Duffy, S. Dytman, B. Eberly, A. Ereditato, L. Escudero Sanchez, J. J. Evans, G. A. Fiorentini Aguirre, R. S. Fitzpatrick, B. T. Fleming, N. Foppiani, D. Franco, A. P. Furmanski, D. García-Gámez, S. Gardiner, G. Ge, S. Gollapinni, O. Goodwin, E. Gramellini, P. Green, H. Greenlee, Wei Gu, R. Guénette, P. Guzowski, E. Hall, P. Hamilton, O. Hen, G. A. Horton-Smith, A. Hourlier, E.-c. Huang, R. Itay, C. James, J. Jan de Vries, Xiangpan Ji, L. Jiang, J. H. Jo, R. A. Johnson, Y.-j. Jwa, N. Kamp, G. Karagiorgi, W. Ketchum, B. Kirby, M. Kirby, T. Kobilarcik, I. Kreslo, R. LaZur, I. Lepetic, K. Li, Y. Li, B. R. Littlejohn, D. Lorca, W. C. Louis, X. Luo, A. Marchionni, S. Marcocci, C. Mariani, D. Marsden, J. Marshall, J. Martín-Albo, D. A. Martínez Caicedo, K. Mason, A. Mastbaum, N. McConkeyJournal of Instrumentation 2021 · DOI · arXiv

Abstract

The MicroBooNE experiment, a liquid argon time projection chamber (LArTPC) located near the surface at Fermilab, has performed a measurement of the atmospheric muon rate. Utilizing both charge collection and scintillation light readout, the collaboration compared experimental data against cosmic-ray simulations. The results demonstrate strong agreement between observation and simulation, validating the modeling tools necessary for surface-based neutrino physics.

Introduction: The Challenge of Surface-Based Neutrino Physics

Neutrino detectors located near the Earth's surface face a significant challenge: cosmic-ray backgrounds. High-energy particles from space constantly interact with the upper atmosphere, producing showers of secondary particles, primarily muons. For the MicroBooNE detector, situated just 6 meters underground, this results in approximately 10 atmospheric muons entering the active volume during every 2.3-millisecond data-taking window.

While these muons represent a source of background noise for neutrino searches, they also serve as a "standard candle" for detector calibration. Accurate modeling of this cosmic flux is essential for distinguishing rare neutrino interactions from the constant "rain" of atmospheric particles. This study focuses on validating the CORSIKA simulation framework against real-world LArTPC data.

Experimental Setup and Methodology

The MicroBooNE detector is housed within the Liquid Argon Test Facility (LArTF) at Fermilab. The detector's environment includes significant shielding from the surrounding concrete pit and building structure, which must be accounted for in simulations.

Schematic of the MicroBooNE detector environment, showing the cryostat located in a concrete pit below ground level.

To measure the muon rate, the researchers employed two independent detection systems:

  1. The Time Projection Chamber (TPC): This system records the ionization electrons produced by muons as they traverse the liquid argon. The Pandora reconstruction framework is used to identify and reconstruct these signals into 3D tracks.
  2. The Photon Detection System: A collection of 32 Photomultiplier Tubes (PMTs) detects the prompt scintillation light emitted by the argon. This provides a measurement independent of the electronic drift required by the TPC.
Reconstructed muon tracks in the MicroBooNE TPC. The red lines indicate the paths identified by the reconstruction software.

A critical aspect of the TPC reconstruction is correcting for the Space Charge Effect. Positive ions, which move much slower than electrons, can build up in the detector, distorting the electric field and causing reconstructed tracks to appear shorter than their true length. The team utilized data-driven models to mitigate these distortions.

Data and Simulation Comparison

The study utilized an unbiased data stream of 25,000 events collected in early 2016. These were compared against large-scale simulations generated using CORSIKA v7.4003 and Geant4. The simulations accounted for the specific geometry of the LArTF building, as the density of concrete in the roof and walls was found to be a major source of systematic uncertainty (approximately 2.7%).

The analysis found excellent consistency between the two detection systems. The data-to-simulation ratio for the TPC was $1.014 \pm 0.004 \text{ (stat)} \substack{+0.028 \\ -0.022} \text{ (sys)}$, while the PMT system yielded $0.990 \pm 0.003 \text{ (stat)} \substack{+0.032 \\ -0.028} \text{ (sys)}$.

Key Insights and Results

The measured atmospheric muon rate, extrapolated to the surface, is approximately 127–130 events/s/m². This result aligns well with previous measurements and confirms that the CORSIKA "default" flux model accurately represents the environment at Fermilab.

Furthermore, the TPC demonstrated exceptional precision, achieving an angular resolution of roughly 0.2° for the zenith angle. However, the study noted that the simulation tends to underpredict the flux of "horizontal" muons (those with zenith angles greater than 75°), likely due to the finite geometric boundaries of the simulated volume.

Conclusion

By successfully measuring the atmospheric muon rate using both charge and light, MicroBooNE has validated the simulation tools required for the next generation of LArTPC experiments. The high degree of agreement between data and Monte Carlo simulations provides confidence in the detector's ability to handle cosmic backgrounds, a prerequisite for the high-precision neutrino physics planned for the Short-Baseline Neutrino (SBN) program and DUNE.

Summary updated

Abstract

Abstract is a near-surface liquid argon (LAr) time projection chamber (TPC) located at Fermilab. We measure muons originating from cosmic interactions in the atmosphere using both the charge collection and light readout detectors. The data is compared with the cosmic-ray simulation. Agreement is found between the observation, simulation and previous results. Furthermore, the angular resolution of the reconstructed muons inside the TPC is studied in simulation.
BibTeX
@article{abratenko2021measurement,
  author = {P. Abratenko and M. Alrashed and R. An and J. Anthony and J. Asaadi and A. Ashkenazi and S. Balasubramanian and B. Baller and C. Barnes and G. Barr and V. Basque and M. Bass and L. Bathe-Peters and O. Benevides Rodrigues and S. Berkman and A. Bhanderi and A. Bhat and M. Bishai and A. Blake and T. Bolton and L. Camilleri and D. Caratelli and I. Caro Terrazas and R. Castillo Fernández and F. Cavanna and G. B. Cerati and Y. Chen and E. Church and D. Cianci and J. M. Conrad and M. Convery and L. Cooper-Troendle and J. I. Crespo-Anadón and M. Del Tutto and D. Devitt and R. Diurba and L. Domine and R. Dorrill and K. Duffy and S. Dytman and B. Eberly and A. Ereditato and L. Escudero Sanchez and J. J. Evans and G. A. Fiorentini Aguirre and R. S. Fitzpatrick and B. T. Fleming and N. Foppiani and D. Franco and A. P. Furmanski and D. García-Gámez and S. Gardiner and G. Ge and S. Gollapinni and O. Goodwin and E. Gramellini and P. Green and H. Greenlee and Wei Gu and R. Guénette and P. Guzowski and E. Hall and P. Hamilton and O. Hen and G. A. Horton-Smith and A. Hourlier and E.-C. Huang and R. Itay and C. James and J. Jan de Vries and Xiangpan Ji and L. Jiang and J. H. Jo and R. A. Johnson and Y.-J. Jwa and N. Kamp and G. Karagiorgi and W. Ketchum and B. Kirby and M. Kirby and T. Kobilarcik and I. Kreslo and R. LaZur and I. Lepetic and K. Li and Y. Li and B. R. Littlejohn and D. Lorca and W. C. Louis and X. Luo and A. Marchionni and S. Marcocci and C. Mariani and D. Marsden and J. Marshall and J. Martín-Albo and D. A. Martínez Caicedo and K. Mason and A. Mastbaum and N. McConkey},
  title = {{Measurement of the atmospheric muon rate with the MicroBooNE Liquid Argon TPC}},
  journal = {Journal of Instrumentation},
  year = {2021},
  doi = {10.1088/1748-0221/16/04/p04004},
}