Measurement Method of Displacement Parameters to Develop Tactile Sensors for Dextrous Fingers Using Inverse of Optical Projection.

Tokuji Okada, Kinya Inamura, Shinichi NakajimaJournal of the Robotics Society of Japan 1994 · DOI

Abstract

This paper presents a refined optical displacement measurement method for tactile sensors designed for dextrous robotic fingers. Utilizing a suspension shell mechanism, the sensor can detect arbitrary force direction, position, and pressure. By defining five spatial parameters—circumferential, directional, inclinational, axial, and radial displacements—the authors propose a measurement technique based on the inverse of optical projection. Four point-light sources on the shell project spots through a pinhole onto a 2D photosensor. Vector analysis is then used to reconstruct the shell's 3D pose, enabling high-resolution sensing within a compact cylindrical body.

Introduction: The Need for Dextrous Sensing

For a robot to perform dextrous manipulation—such as rolling a pen or handling delicate objects—it requires sensors that perceive more than simple contact pressure. Effective manipulation necessitates understanding the magnitude, direction, and point of application of external forces.

Existing tactile sensors often face significant trade-offs. Mechanical sensors are robust but suffer from backlash and friction, while magnetic sensors are precise but vulnerable to electromagnetic interference (EMC). Optical sensors offer high resolution and noise immunity but are typically bulky or limited to measuring "normal" force. This research bridges the gap by creating a compact, 5-degree-of-freedom (5-DOF) sensor that fits inside a slim cylindrical finger and can detect complex sliding, twisting, and tilting displacements.

The Suspension Shell Mechanism

The core of the sensor is a suspension shell mechanism. In this design, a rigid outer shell "floats" over the finger's internal structure, held in place by a series of springs. When the finger interacts with an object, the external force causes the shell to shift, tilt, or rotate relative to the internal body.

The suspension shell mechanism uses springs to allow an outer shell to move relative to the internal finger body.

By measuring the displacement of this shell, the sensor can infer the characteristics of the applied force. The challenge lies in accurately capturing these multi-dimensional movements within the tight spatial constraints of a robotic digit.

Measuring 5-DOF Displacement via Inverse Optical Projection

To measure the shell's movement, the authors developed a method based on the inverse of optical projection. The hardware setup consists of four point-light sources (LEDs) mounted on a cross-section of the internal "floating" shell. A single pinhole and a 2D position-sensitive detector (PSD) are fixed to the finger's rigid internal body.

As the shell moves, light from the LEDs passes through the pinhole, creating four distinct spots on the PSD. The system uses a vector analysis algorithm to "reverse" the projection mathematics, solving for five distinct spatial parameters:

  • $\beta$: Rotation around the finger axis (torsion).
  • $\gamma$: The direction of the radial shift.
  • $\alpha$: The angle of inclination (tilt).
  • $\lambda$: Axial displacement (sliding along the finger).
  • $\rho$: Radial displacement (pushing into the finger).
Geometric model defining the five displacement parameters using inverse optical projection.

This "inverse projection" approach allows the system to reconstruct 3D motion from 2D sensor data. By using four light sources instead of one or two, the system can mathematically decouple rotation from translation, a common difficulty in compact tactile sensing.

Sensitivity and Mathematical Validation

The researchers validated their mathematical model using simulated displacement data. Within a defined dynamic range (e.g., tilts within ±10 degrees and displacements within ±2mm), the inverse projection algorithm successfully recovered the original input parameters from synthetic PSD spot coordinates.

A key finding of the study is that measurement sensitivity is geometrically dependent. The sensitivity to small displacements increases as the light sources move closer to the pinhole along the axial (Z) dimension. This provides a critical design rule for future hardware: the optical components should be positioned where the most frequent or critical contacts are expected to occur.

Conclusion

This research demonstrates that a single optical set—comprising one PSD, one pinhole, and four LEDs—is sufficient to capture high-fidelity 5-DOF tactile data. This efficiency allows the entire mechanism to be embedded in a slim, cylindrical robot finger without the bulk associated with traditional multi-axis sensors.

Future work will focus on transitioning from simulation to physical prototypes, addressing real-world factors such as ambient light interference and the mechanical modeling required to convert measured displacements into precise force vectors.

Summary updated

Abstract

This paper describes a revised optical displacement measurement method to develop tactile sensors based on a suspension shell mechanism for dextrous fingers, so that the sensor can detect arbitrary force in direction, in addition to the position and pressure of an external force. To express variables of the position and orientation of the suspension-shell, five parameters regarding circumferential, directional, and inclinational displacements, and also axial and radial displacements are defined. Then a method of measuring these five parameters using inverse of optical projection is proposed. Point source of lights are attached on a medium section of the suspension shell and lighten a pinhole to produce light spots on a 2-D photosensor through a pinhole. Vector analysis for reverting the values of parameters are shown. Also, characteristics of measurement sensitivity depending on a position of the medium section in the dynamic range of the shell is evaluated. The method is characterized by the fact that only an optical set embedded in a cylindrical body is enough to measure the displacement paramerters and to make fingers smart.
BibTeX
@article{okada1994measurement,
  author = {Tokuji Okada and Kinya Inamura and Shinichi Nakajima},
  title = {{Measurement Method of Displacement Parameters to Develop Tactile Sensors for Dextrous Fingers Using Inverse of Optical Projection.}},
  journal = {Journal of the Robotics Society of Japan},
  year = {1994},
  doi = {10.7210/jrsj.12.310},
}
Figure