mDurance: A Novel Mobile Health System to Support Trunk Endurance Assessment

Oresti Banos, José Antonio Moral-Muñoz, Ignacio Diaz Reyes, Manuel Arroyo Morales, Miguel Damas, Enrique Herrera-Viedma, Choong Seon Hong, Sungyong Lee, Héctor Pomares, Ignacio Rojas, Claudia Villalonga2015

TL;DR

This paper introduces mDurance, a novel mobile health system that leverages wearable inertial and electromyography (EMG) sensors to objectively assess trunk endurance. By automating measurements and providing real-time feedback, mDurance aims to overcome the limitations of traditional subjective assessment methods, offering a more reliable and efficient tool for physical therapists and researchers.

What Problem Does This Paper Address?

Low back pain (LBP) is a pervasive and disabling musculoskeletal condition with significant socioeconomic impact. Trunk endurance assessment is crucial for LBP rehabilitation, but traditional methods are plagued by practical limitations. These include the subjectivity of visual estimation for test start/end times, potential for human error in measurement, and the difficulty in consistently comparing results across different testers or sessions. This subjectivity can lead to inaccurate diagnoses and hinder effective treatment monitoring. The authors propose mDurance to address these challenges by introducing a digital, sensor-based system.

Methods

The mDurance system is built upon a mobile health framework and integrates several key components:

  • Wearable Inertial Measurement Unit (IMU): This sensor tracks the patient's trunk posture by measuring acceleration, angular rate, and magnetic field data. The system uses Madgwick's algorithm to fuse this data and derive a quaternion representation of motion, which is then translated into Euler angles (specifically, the roll angle) to represent trunk orientation. This allows for automatic determination of the start and end of endurance tests based on predefined criteria.
  • Wearable Electromyography (EMG) Sensor: This sensor measures the electrical activity of the trunk muscles. It uses surface electrodes to capture the potential difference between muscles, which is then processed into EMG signals. The system calculates key fatigue metrics such as Root Mean Square (RMS), Average Rectified Value (ARV), and Maximum Voluntary Muscle Contraction (MVC) from these signals.
  • Mobile Application: A custom Android application, developed using the mHealthDroid framework, serves as the central hub. It handles sensor connection, data acquisition, processing, storage, and visualization. The app guides the expert through test execution, displays real-time trunk angle and EMG data, and provides a summary of results, including test duration and fatigue metrics.

Datasets

Not discussed in the paper. The study describes a case study with ten volunteers, but no specific datasets for training or large-scale evaluation are mentioned.

Key Insights and Ideas

  • Objective Measurement for Subjective Tasks: The core innovation is the digitization of a highly subjective clinical assessment. By using sensors, mDurance removes the reliance on visual interpretation for critical timing and posture cues.
  • Real-time Feedback for Experts: The system provides immediate visual feedback on trunk angle and muscle activity (EMG). This allows experts to not only monitor the test objectively but also to potentially identify subtle issues in muscle activation or fatigue during the exercise.
  • Automated Data Logging and Analysis: The system automatically records all relevant data, including test duration, trunk angle, and EMG-derived fatigue metrics. This eliminates manual data entry errors and facilitates easier comparison of progress over time.
  • Potential for Personalized Rehabilitation: The ability to track detailed metrics over multiple sessions suggests mDurance could be a powerful tool for monitoring patient improvement and tailoring rehabilitation programs.

Key Results

  • Inter-rater Reliability: A preliminary evaluation with three physical therapists and ten volunteers showed high inter-rater reliability between traditional methods and mDurance. ICC values were excellent for STEET (0.92) and TCSET (0.89), and good for SBET right (0.84) and SBET left (0.75). Cronbach's alpha values also indicated good to excellent reliability.
  • Usability: The System Usability Scale (SUS) scores averaged 84.29 ± 5.15 among seven independent experts, indicating high levels of acceptability, ease of use, and confidence.
  • Qualitative Feedback: Experts found the automatic angle measurement practical, the app guidance for posture more adequate than visual inspection, and were impressed with the precision of angle estimation and real-time EMG representation. They highlighted the value of automated logging for tracking patient progress.

Limitations and Future Work

  • Limited Sample Size: The evaluation involved only ten volunteers and seven experts. The authors acknowledge that a larger study with patients suffering from LBP is needed to further confirm the findings.
  • Sensor Connection Simplicity: While overcome, experts experienced initial difficulties connecting the sensors, suggesting a need for simpler guidelines or a more streamlined connection process.
  • Data Sharing: The current system is limited to a single device. Experts suggested the desirability of sharing data across diverse platforms for broader accessibility.
  • Future Work: The authors plan to conduct large-scale clinical trials and are developing the system further to address the identified limitations, particularly regarding data sharing and user guidance.

Summary updated