MCP-Net: Real-Time Coronary Perception Network and Topological Analysis for Robotic Guidewire Navigation

Sahar Nasirihaghighi, Tianyuan Wang, Kenan Niu, Stefano StramigioliarXiv 2026

In the high-stakes world of interventional cardiology, navigating a hair-thin guidewire through the twisting, branching "tree" of coronary arteries is a feat of extreme manual dexterity. Surgeons rely on 2D X-ray fluoroscopy—images that are often low-contrast, noisy, and distorted by the constant motion of a beating heart. While AI has made strides in segmenting these vessels, a robot needs more than just a pixel mask to operate; it needs a map.

Enter MCP-Net, a new multi-task framework designed to provide real-time, structured perception for robotic guidewire navigation.

TL;DR

MCP-Net is a deep learning framework that transforms raw 2D X-ray images into a structured, "GPS-like" navigation roadmap for robotic heart surgery. By jointly localizing the guidewire, identifying blockages (stenosis), and extracting the vascular topology in real-time, it bridges the gap between computer vision and autonomous robotic control.

What Problem Does This Paper Address?

Percutaneous Coronary Intervention (PCI) requires a surgeon to thread a guidewire to a specific blockage. This is difficult because:

  1. Visual Complexity: 2D X-rays lose depth information, and vessels often overlap.
  2. Fragmented AI: Most existing tools treat vessel segmentation and device tracking as separate tasks. A robot, however, needs to know how these elements relate—e.g., "Is the wire tip currently in the correct branch leading to the target?"
  3. Data Scarcity: Getting high-quality, annotated clinical data is incredibly hard. Labeling every tiny branch in a moving X-ray is a nightmare for human experts.

The authors tackle these issues by creating a system that doesn't just "see" pixels but understands the topology (the connectivity and branching structure) of the coronary tree.

Methods

The researchers developed a "simulation-driven" pipeline that moves from raw 3D data to a real-time 2D navigation aid.

Overview of the MCP-Net framework, showing the transition from 3D CT simulation to real-time multi-task inference and roadmap generation.

1. Physics-Based Simulation

Since real annotated data is scarce, they used 3D Coronary CT Angiography (CCTA) to simulate realistic 2D X-ray projections. Because they started with 3D models, they had "perfect" ground truth for vessel masks, guidewire positions, and the exact location of simulated stenotic lesions.

2. The MCP-Net Architecture

At the heart of the system is a Multi-Task Coronary Perception Network. Using a shared ResNet-50 backbone, it branches into three specialized "heads":

  • Vessel Segmentation: Uses a DeepLabV3+ decoder to create a binary mask of the arteries.
  • Guidewire Tip Localization: Uses heatmap regression to pinpoint the wire's end.
  • Stenosis Localization: Identifies three landmarks (the start, throat, and end of the blockage) to estimate its severity and extent.

3. From Pixels to Graphs

The system doesn't stop at a 2D mask. It performs topological analysis, skeletonizing the vessel mask into a mathematical graph where nodes are bifurcations and edges are vessel segments. This allows the system to calculate a "shortest path" from the root of the artery to the target lesion, providing a clear roadmap for a robot to follow.

Datasets

The study utilized the ImageCAS dataset, which contains 376 high-quality 3D coronary CT volumes. From these, they generated 1,504 simulated fluoroscopy images (256x256 pixels) across diverse vascular geometries and projection angles. The data was split at the patient level to ensure the model wasn't just memorizing specific heart shapes.

Key Insights and Ideas

  • Connectivity Matters More Than Overlap: The authors emphasize clDice (centerline Dice) over standard Dice scores. For navigation, it's more important that a vessel branch is connected to the main trunk than if its edges are perfectly aligned at the pixel level. A break in the segmentation "breaks" the robot's map.
  • The Power of Multi-Tasking: By training on vessels, wires, and lesions simultaneously, the network learns a more robust feature representation. This is more computationally efficient than running three separate models.
  • Actionable Representations: The "aha moment" here is the conversion of deep learning outputs into a structured graph. This turns a "black box" prediction into an interpretable format that traditional robotic path-planning algorithms can use.

Key Results

The framework is remarkably fast and accurate:

  • Real-Time Performance: The entire pipeline—from image input to roadmap generation—runs at 37.2 FPS on an NVIDIA GPU, well above the standard fluoroscopy frame rate.
  • High Fidelity: It achieved a 96.0% clDice score, indicating excellent preservation of the vascular structure.
  • Precise Tracking: The guidewire tip was localized with a median error of just 1.09 pixels.
Fig. 2. Localization accuracy as a function of pixel tolerance for guidewire- tip and stenosis-throat localization on the simulated test set.

As shown in the PCK curve above, guidewire tracking is highly reliable (88% accuracy within a 5-pixel tolerance), while identifying the exact "throat" of a stenosis remains a slightly more difficult task due to the visual ambiguity of lesions.

Limitations and Future Work

The primary hurdle is the domain gap. While the simulations are sophisticated, real-world clinical X-rays contain complex artifacts, varying contrast agent concentrations, and unpredictable patient motion that simulations might not fully capture.

The authors suggest that future work will focus on "Simulation-to-Real" (Sim2Real) adaptation techniques to bridge this gap. Ultimately, the goal is to integrate this roadmap into a closed-loop control system, allowing a robot to autonomously (or semi-autonomously) steer a guidewire through the heart.

Summary updated

Abstract

Coronary guidewire navigation during percutaneous coronary intervention requires continuous interpretation of vessel anatomy, guidewire position, and target stenosis under two-dimensional X-ray fluoroscopy. While existing approaches commonly address vessel segmentation or device localization as separate tasks, a robotic system requires a more structured perception of the coronary scene to support downstream navigation. In this work, we present a simulation-driven framework centered on a Multi-Task Coronary Perception Network (MCP-Net) for robotic guidewire navigation, integrating coronary vessel segmentation, vascular topology extraction, and roadmap generation. Starting from three-dimensional coronary CT angiography, we generate simulated fluoroscopy images containing vascular structures, simulated guidewires, stenotic lesions with varying severity, and diverse vascular geometries, together with simulation-derived ground truth. MCP-Net jointly performs coronary vessel segmentation, guidewire-tip localization, and stenosis localization from a single fluoroscopic frame. These predictions are subsequently converted into a structured vascular graph containing centerlines, bifurcations, endpoints, branch directions, and branch angles. By associating the predicted stenosis with this graph, the framework generates a roadmap from the automatically selected graph root toward the target lesion. The results demonstrate that the proposed framework can jointly recover coronary perception targets and transform them into an interpretable vascular representation suitable for downstream robotic navigation.
BibTeX
@misc{nasirihaghighi2026mcp,
  author = {Sahar Nasirihaghighi and Tianyuan Wang and Kenan Niu and Stefano Stramigioli},
  title = {{MCP-Net: Real-Time Coronary Perception Network and Topological Analysis for Robotic Guidewire Navigation}},
  year = {2026},
  eprint = {2610.37127},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.37127},
}