MAXIV Photocathode Gun Laser System Specification and Diagnostics

Filip Lindau, Joel Andersson, Jonas Björklund Svensson, Mathias Brandin, Francesca Curbis, Lennart Isaksson, Marija Kotur, Dionis Kumbaro, Erik Mansten, David Olsson, Robin Svärd, Sara Thorin, Sverker WerinLund 2017

Abstract

The MAXIV injector has two guns - a thermionic used for ring injections, and a photocathode used for short pulse facility operation. A commercial Ti:sapphire laser from KMLabs drives the copper based photocathode gun. It has been running without major issues for more than 3 years. The laser delivers up to §I{500}{\textmu J} on the cathode at the third harmonic, §I{263}{nm}, via a vacuum laser transport system. To achieve the desired pulse duration of 2–§I10{ps} the laser pulses, originally ~§I{100}{fs} long, are stretched with a prism pair and the resulting §I{1.5}{ps} pulses stacked by a series of birefringent \textalpha -BBO crystals. Diagnostics consist of photodiodes, spectrometers, and cameras. Longitudinal pulse characterization is done with a cross correlator and a UV FROG.
BibTeX
@inproceedings{lindau2017maxiv,
  author = {Filip Lindau and Joel Andersson and Jonas Björklund Svensson and Mathias Brandin and Francesca Curbis and Lennart Isaksson and Marija Kotur and Dionis Kumbaro and Erik Mansten and David Olsson and Robin Svärd and Sara Thorin and Sverker Werin},
  title = {{MAXIV Photocathode Gun Laser System Specification and Diagnostics}},
  booktitle = {Lund},
  year = {2017},
  doi = {10.18429/jacow-ipac2017-tupab097},
}