Marine radioisotope gamma-ray spectrum analysis method based on Geant4 simulation and MLP neural network

W. H. Dai, Zhi Zeng, Daolong Dou, Huimin Ma, Jian Cheng, Jiawen Li, Hui ZhangJournal of Instrumentation 2021 · DOI

Abstract

The monitoring of marine $^{137}\text{Cs}$ using a scintillation detector relies on the spectrum analysis method to extract the $^{137}\text{Cs}$ concentration. However, when in a poor statistics situation, the calculation result of the traditional net-peak-area (NPA) method has large uncertainty. In this paper, therefore, a new machine-learning-based method is presented to better analyze gamma-ray spectra with low $^{137}\text{Cs}$ concentration. A multilayer perceptron (MLP) is applied to analyze the 662-keV full energy peak of $^{137}\text{Cs}$ in seawater spectra; the MLP can be trained with a few measured background spectra by combining the simulated $^{137}\text{Cs}$ spectra with measured background spectra. Thus, the time to prepare and measure standard samples for generating the training dataset can be saved. To validate the MLP-based method, Geant4 and background gamma-ray spectra measured by a seaborne monitoring device are used to generate an independent test dataset for testing the results obtained by the proposed MLP-based and traditional NPA methods. It is found that the MLP-based method achieves a root-mean-square error of 0.159, 2.3 times lower than that of the traditional NPA method, indicating that the MLP-based method improves the precision of $^{137}\text{Cs}$ concentration calculations.

Introduction

Monitoring radioactive isotopes like $^{137}\text{Cs}$ in the ocean is a critical task for environmental safety, especially following events like the 2011 Fukushima nuclear accident. Scientists typically use seaborne scintillation detectors, such as $\text{LaBr}_3$ crystals, to measure gamma-ray spectra. The standard approach, known as the Net Peak Area (NPA) method, calculates concentration based on the counts within a specific energy peak (662 keV for $^{137}\text{Cs}$). However, when concentrations are very low, the signal is often "buried" under statistical fluctuations and background radiation. In these "poor statistic" scenarios, the NPA method becomes highly uncertain, leading to potential false alarms or missed contamination events.

Methodology

To address these limitations, researchers developed a "simulation-augmented" machine learning workflow using a Multilayer Perceptron (MLP).

Simulation and Data Acquisition

Instead of the time-consuming process of preparing physical standard samples, the team utilized Geant4 to simulate gamma-ray transport and detection for $^{137}\text{Cs}$ within a specific monitoring device. This device, shown in Figure 1, includes a $\text{LaBr}_3$ detector housed in a shielded chamber.

Physical monitoring device and the 645 measured background spectra used for training.

The training data was constructed by combining 100 simulated signal spectra with 645 real-world background spectra measured during sea trials. These background spectra include natural radiation from $^{40}\text{K}$ and intrinsic activity from the detector itself. By summing these channel-by-channel, a robust dataset of 64,500 spectra was generated.

MLP Architecture

The researchers employed an MLP with 10 hidden layers. To optimize efficiency and prevent the model from being distracted by unrelated background peaks (such as the $^{138}\text{La}$ peak at 700-1100 keV), the input was restricted to a narrow energy window of 620–710 keV, covering 30 spectral channels. The model was trained for both regression (predicting exact concentration) and classification (detecting if levels exceed a 0.7 Bq/L threshold).

Key Results and Insights

The MLP-based method demonstrated significant improvements over traditional techniques. One of the primary advantages is the model's ability to "see" the 662 keV peak even when it is visually indistinguishable from noise, a common occurrence at low concentrations.

Normalized gamma-ray spectra showing the overlap between low and high 137Cs concentrations near the 662 keV peak.

Performance Metrics

  • Precision: The MLP-based method achieved a Root Mean Squared Error (RMSE) of 0.159, which is 2.3 times lower than the NPA method's error of 0.364.
  • Detection Sensitivity: At the regulatory limit of 0.7 Bq/L, the MLP correctly identified 99.8% of abnormal samples, compared to only 89.7% for the NPA method.
  • Classification Accuracy: The Area Under the ROC Curve (AUC) for the MLP was 0.9932, significantly outperforming the NPA's 0.9567.

The validation that simulated signals can be successfully blended with real background noise is a major breakthrough, as it bypasses the logistical challenges of handling radioactive standard samples in a laboratory setting.

Conclusion and Future Work

While the MLP offers superior performance, its "black box" nature and sensitivity to detector stability (e.g., peak drift due to temperature) are hurdles for real-world deployment. Future work will involve refining the Geant4 simulations with limited physical measurements and adapting the method for other radionuclides like Iodine-131. This approach represents a significant step forward in our ability to monitor marine radioactive contamination with high precision and efficiency.

Summary updated

Abstract

Abstract The monitoring of marine 137 Cs using a scintillation detector relies on the spectrum analysis method to extract the 137 Cs concentration. However, when in a poor statistics situation, the calculation result of the traditional net-peak-area (NPA) method has large uncertainty. In this paper, therefore, a new machine-learning-based method is presented to better analyze gamma-ray spectra with low 137 Cs concentration. A multilayer perceptron (MLP) is applied to analyze the 662-keV full energy peak of 137 Cs in seawater spectra; the MLP can be trained with a few measured background spectra by combining the simulated 137 Cs spectra with measured background spectra. Thus, the time to prepare and measure standard samples for generating the training dataset can be saved. To validate the MLP-based method, Geant4 and background gamma-ray spectra measured by a seaborne monitoring device are used to generate an independent test dataset for testing the results obtained by the proposed MLP-based and traditional NPA methods. It is found that the MLP-based method achieves a root-mean-square error of 0.159, 2.3 times lower than that of the traditional NPA method, indicating that the MLP-based method improves the precision of 137 Cs concentration calculations.
BibTeX
@article{dai2021marine,
  author = {W. H. Dai and Zhi Zeng and Daolong Dou and Huimin Ma and Jian Cheng and Jiawen Li and Hui Zhang},
  title = {{Marine radioisotope gamma-ray spectrum analysis method based on Geant4 simulation and MLP neural network}},
  journal = {Journal of Instrumentation},
  year = {2021},
  doi = {10.1088/1748-0221/16/06/p06030},
}
Figure