Magnetic Force Investigation of High-Tc Superconducting Bulk over Permanent Magnet Railway under Different Lateral Offsets with Experimental Methods

Yiyun Lu, Daqing He, Minxian LiuJournal of Modern Physics 2013 · DOI

Abstract

The performance of high-Tc superconducting (HTS) maglev transportation systems is heavily dependent on the interaction between HTS bulks and permanent magnet railways (PMR). This study experimentally investigates the magnetic levitation force of a cylindrical YBCO bulk over two types of PMRs—symmetrical and Halbach—under varying lateral offsets. Results indicate that while levitation force decreases linearly with lateral offset for symmetrical PMRs, Halbach PMRs exhibit a peak performance at a specific offset (25 mm). These findings provide essential design guidelines for optimizing superconductor arrays in maglev vehicles.

Introduction

High-temperature superconducting (HTS) maglev systems utilize the "flux pinning" effect, where a superconductor like Yttrium Barium Copper Oxide (YBCO) is stably locked within the magnetic field of a permanent magnet railway (PMR). In practical applications, these superconductors are arranged in complex arrays rather than individual units. To maximize lift and stability, engineers must understand how the magnetic field distribution of the rail interacts with the superconductors at various lateral positions. This paper specifically addresses how the maximum levitation force changes as a superconductor is shifted laterally across different rail geometries.

Experimental Methods

The researchers utilized a custom-built measurement apparatus to test a single cylindrical YBCO bulk (30 mm diameter, 15 mm thickness). Two distinct PMR designs were evaluated:

  1. Symmetrical PMR: Comprising two NdFeB magnets with a central iron core to concentrate flux.
  2. Halbach PMR: An arrangement of five NdFeB magnets designed to augment the magnetic field on one side while cancelling it on the other.

Using the Zero-Field Cooling (ZFC) method, the bulk was cooled to superconducting temperatures away from the magnets and then moved vertically toward the rail to measure "force-gap loops" (the relationship between distance and lift). These measurements were repeated at lateral offsets ranging from 0 mm (dead center) to 30 mm in 5 mm increments.

Results and Discussion

The study highlights that levitation performance is dictated by the geometric "signature" of the magnetic field rather than just magnet strength.

Magnetic field distributions for (a) Symmetrical PMR and (b) Halbach PMR.

As shown in Figure 3, the symmetrical rail acts similarly to a single magnetic pole, with the highest flux density at the center. In contrast, the Halbach array behaves like a double pole, creating a peak in magnetic flux density that is physically offset from the rail's geometric center. This explains the "sweet spot" observed in the Halbach experimental data.

For the symmetrical PMR, the experimental data (Figure 4) demonstrates a clear trend: the maximum levitation force decreases linearly as the lateral offset increases. At the center (0 mm), the force is approximately 45 N, dropping to roughly 10 N at a 30 mm offset.

Magnetic levitation force vs. vertical displacement gap for YBCO bulk over symmetrical PMR at various lateral offsets.

Furthermore, the force-gap loops exhibit significant hysteresis. Because the superconductor "traps" magnetic flux, the path of the force during descent differs from the path during ascent. This "memory" effect is a hallmark of flux pinning in HTS materials.

In the case of the Halbach PMR, the trend was non-monotonic. The force started at ~40 N at the center, increased as the bulk moved outward, and reached a peak of nearly 80 N at a 25 mm offset. Beyond this point, the force dropped sharply. This suggests that the Halbach rail, when utilized at its optimal offset, provides nearly double the peak levitation force compared to the symmetrical rail.

Conclusion

The investigation concludes that the external magnetic field distribution is the primary factor influencing HTS bulk levitation performance. For systems using symmetrical rails, a staggered bulk arrangement is recommended to maintain stability. For Halbach-based systems, a matrix arrangement that positions bulks near the 25 mm offset mark can significantly enhance lift. Future work should address dynamic effects at high speeds and the interaction between multiple bulks in an array.

Summary updated

Abstract

The magnetic levitation transportation system is one of the potential applications of high-Tc superconducting (HTS) maglev system. The prototype HTS magnetic levitation system is composed of one HTS bulk and a permanent magnet railway (PMR). The maglev transportation system performance is influenced by the maximum levitation force, the maximum guidance force and the maximum of external applied magnetic flux density. The applied magnetic field distribution also needs to be considered carefully. In the paper, the magnetic levitation force of cylindrical HTS bulk over PMR is experimentally studied. During the experiment, symmetrical PMR and Halbach PMR are used separately. The levitation force-gap loops of different lateral offset of the HTS bulk above PMRs are obtained experimentally. The results show that the HTS bulk levitation performance is tightly relative to the external applied magnetic field distribution. The maximum magnetic levitation forces of HTS bulk above symmetrical PMR decrease linearly with the lateral offset increasing. When the lateral offset changes from 0 mm to 25 mm, the maximum magnetic levitation forces of HTS bulk above Halbach PMR increase with the lateral offset increasing. When the lateral offset exceeds the center of the Halbach PMR by 25 mm, the maximum force decreases rapidly with the increase of the lateral offset of the bulk sample.
BibTeX
@article{lu2013magnetic,
  author = {Yiyun Lu and Daqing He and Minxian Liu},
  title = {{Magnetic Force Investigation of High-Tc Superconducting Bulk over Permanent Magnet Railway under Different Lateral Offsets with Experimental Methods}},
  journal = {Journal of Modern Physics},
  year = {2013},
  doi = {10.4236/jmp.2013.46a006},
}
Figure