Machine Learning-Assisted E-jet Printing of Organic Flexible Biosensors

Mehran Abbasi Shirsavar, Mehrnoosh Taghavimehr, Lionel J. Ouedraogo, Mojan Javaheripi, Nicole N. Hashemi, Farinaz Koushanfar, Reza MontazamiarXiv 2021

Abstract

Flexible organic electronics are pivotal for the next generation of wearable health monitoring systems. However, manufacturing these devices using electrohydrodynamic-jet (e-jet) printing is often hindered by the complex, non-linear relationship between printing parameters and final device performance. This paper presents a machine learning (ML) framework designed to predict the electrical functionality of printed graphene circuits. By analyzing a dataset of 240 experimental samples, ensemble models like AdaBoost and Random Forest achieved predictive accuracies up to 87%. These results demonstrate that ML can effectively bypass traditional trial-and-error methods, optimizing the fabrication of high-resolution flexible biosensors.

Introduction

The demand for flexible, wearable electronics has surged, necessitating high-resolution printing techniques like electrohydrodynamic-jet (e-jet) printing. Unlike standard inkjet printing, e-jet uses an electric field to pull functional inks from a nozzle, allowing for sub-micron resolution. Despite its precision, e-jet printing is highly sensitive to operational variables including nozzle speed, ink flow rate, and applied voltage. Small deviations can lead to discontinuous paths or "voids," rendering the sensors non-functional.

Flexible graphene-based biosensor printed on a polyimide substrate, shown in flat (a) and bent (b) configurations.

To address this, researchers integrated supervised learning algorithms to predict sensor conductivity based on printing parameters. This shift from manual optimization to predictive modeling aims to conserve expensive materials, such as few-layer graphene (FLG), and accelerate the manufacturing cycle.

Methods and Materials

The study utilized FLG synthesized via Liquid Phase Exfoliation (LPE) to create a high-quality conductive ink. Printing was performed using a modified Prusa i3 3D printer converted into an e-jet system.

A dataset of 240 samples was generated, varying three primary features: nozzle speed (mm/min), voltage (kV), and flow rate (µl/min). The target variable was a binary classification of conductivity: "low-conductance" (Class 0) or "high-conductance" (Class 1), determined by I-V curve measurements. Several ML algorithms were evaluated, including Decision Trees (CART), Random Forest (RF), K-Nearest Neighbors (KNN), AdaBoost, and Logistic Regression. Model robustness was ensured through 10-fold cross-validation and bootstrap resampling.

Results and Discussion

The analysis identified nozzle speed as the most critical parameter for ensuring conductivity. Decision Tree analysis showed that speeds exceeding 500 mm/min frequently resulted in discontinuous graphene networks.

SEM image showing the morphology and connectivity of printed graphene flakes.

Ensemble methods significantly outperformed individual models. AdaBoost emerged as the top performer with 87% accuracy, while Random Forest demonstrated the highest reliability with an Area Under the ROC Curve (AUC) of 0.93. These models effectively captured the physical reality of the printing process, as confirmed by Scanning Electron Microscopy (SEM) images, which showed a direct correlation between ML-predicted "high-conductance" and well-connected flake morphology.

Conclusion

Integrating machine learning into the e-jet printing workflow provides a robust pathway for optimizing flexible electronics. While current models focus on binary classification, future developments aim to predict specific resistance values and implement real-time, closed-loop control systems. This synergy between additive manufacturing and artificial intelligence is essential for the scalable production of reliable organic biosensors.

Summary updated

Abstract

Electrohydrodynamic-jet (e-jet) printing technique enables the high-resolution printing of complex soft electronic devices. As such, it has an unmatched potential for becoming the conventional technique for printing soft electronic devices. In this study, the electrical conductivity of the e-jet printed circuits was studied as a function of key printing parameters (nozzle speed, ink flow rate, and voltage). The collected experimental dataset was then used to train a machine learning algorithm to establish models capable of predicting the characteristics of the printed circuits in real-time. Precision parameters were compared to evaluate the supervised classification models. Since decision tree methods could not increase the accuracy higher than 71%, more advanced algorithms are performed on our dataset to improve the precision of model. According to F-measure values, the K-NN model (k=10) and random forest are the best methods to classify the conductivity of electrodes. The highest accuracy of AdaBoost ensemble learning has resulted in the range of 10-15 trees (87%).
BibTeX
@misc{shirsavar2021machine,
  author = {Mehran Abbasi Shirsavar and Mehrnoosh Taghavimehr and Lionel J. Ouedraogo and Mojan Javaheripi and Nicole N. Hashemi and Farinaz Koushanfar and Reza Montazami},
  title = {{Machine Learning-Assisted E-jet Printing of Organic Flexible Biosensors}},
  year = {2021},
  eprint = {2111.03985},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2111.03985},
}
Figure