<title>Wavefront correction for static and dynamic aberrations to within 1 second of the system shot in the NIF Beamlet demonstration facility</title>

R Hartley, Michael W. Kartz, W. Behrendt, Andy Hines, G.g. Pollock, Erlan S. Bliss, Joseph Salmon, Scott Winters, B. M. Van Wonterghem, R. ZachariasProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 1997 · DOI

Abstract

The laser wavefront of the NIF Beamlet demonstration system is corrected for static aberrations with a wavefront control system. The system operates closed loop with a probe beam prior to a shot and has a loop bandwidth of about 3 Hz. However, until recently the wavefront control system was disabled several minutes prior to the shot to allow time to manually reconfigure its attenuators and probe beam insertion mechanism to shot mode. Thermally-induced dynamic variations in gas density in the Beamlet main beam line produce significant wavefront error.
BibTeX
@inproceedings{hartley1997lt,
  author = {R Hartley and Michael W. Kartz and W. Behrendt and Andy Hines and G.G. Pollock and Erlan S. Bliss and Joseph Salmon and Scott Winters and B. M. Van Wonterghem and R. Zacharias},
  title = {{\<title\>Wavefront correction for static and dynamic aberrations to within 1 second of the system shot in the NIF Beamlet demonstration facility\</title\>}},
  booktitle = {Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE},
  year = {1997},
  doi = {10.1117/12.294315},
}

Loading related content...

Figure