Low-Finesse Fabry–Perot Cavity Design Based on a Reflective Sphere

Ju Wang, Ye Gao, Jinlong Yu, Hao Luo, X.h. Su, Xu Han, Yang Gao, Ben Cai, Chuang MaPhotonics 2025 · DOI

TL;DR

This paper introduces a novel, simplified design for low-finesse Fabry-Perot (F-P) cavities, crucial for high-precision micro-displacement measurements. By using a high-reflectivity spherical mirror and a fiber collimator, the design achieves a finesse of approximately 0.5 without the need for complex angular alignment, making it more practical and accurate.

What Problem Does This Paper Address?

Accurate measurement of tiny displacements is essential in fields like nanotechnology and precision manufacturing. Fabry-Perot (F-P) interferometers are powerful tools for this, but achieving high precision often requires a specific "low-finesse" configuration (finesse ≈ 0.5) for ideal interference. However, existing methods for creating these low-finesse cavities are challenging: they demand extremely precise reflectivity control and meticulous angular alignment of optical components. This makes them complex to build, sensitive to environmental disturbances, and difficult to maintain stability, especially when the cavity is in motion. This paper aims to overcome these limitations by proposing a simpler, more robust design for low-finesse F-P cavities.

Methods

The core innovation is the use of a high-reflectivity spherical mirror in conjunction with the end face of a fiber collimator to form the F-P cavity. This deviates from traditional designs that use planar mirrors. The spherical reflector's curvature is leveraged to manage beam divergence. By carefully selecting the sphere's radius and considering the fiber collimator's acceptance angle and beam radius, the authors quantitatively design the cavity to achieve a finesse of approximately 0.5. This approach inherently simplifies alignment because the spherical surface doesn't require precise perpendicularity to the optical axis; only rough alignment with the sphere's center is needed. The paper also provides a theoretical analysis of the optical path transmission and interference within this novel cavity structure, deriving equations to relate the cavity parameters to finesse.

Datasets

Not discussed in the paper. The study relies on theoretical modeling and experimental measurements using standard optical components.

Key Insights and Ideas

  • Spherical reflector simplifies alignment: The curvature of the spherical mirror eliminates the need for precise angular alignment, a major bottleneck in conventional F-P cavity designs. This significantly reduces manufacturing and setup complexity.
  • High reflectivity sphere is key: Counter-intuitively, using a high-reflectivity sphere, combined with a low-reflectivity fiber end face, allows for the desired low finesse. This is because the sphere's curvature causes beam divergence, effectively reducing the optical reflectivity within the cavity's acceptance angle.
  • Finesse is tunable via sphere diameter: The paper demonstrates that for a fixed collimator, the finesse of the F-P cavity can be precisely controlled by adjusting the diameter of the reflective sphere. This offers a practical way to meet the target finesse of 0.5.
  • Reduced higher-order reflection impact: By keeping the reflectivity of both surfaces low (around 0.04 and 0.02), the influence of multiple reflections is minimized, leading to a cleaner interference spectrum and improved measurement accuracy.

Key Results

The experimental results validate the proposed design.

  • The average finesse values measured using two different fiber collimators were 0.496 and 0.502, both remarkably close to the theoretical target of 0.5.
  • These values were achieved across various working distances, demonstrating the design's stability and robustness.
  • The measured Free Spectral Range (FSR) also aligned with theoretical predictions, further confirming the design's accuracy.
  • The simplified alignment process was confirmed, as the setup only required rough alignment of the beam to the center of the reflective sphere.

Limitations and Future Work

  • Limited to specific collimators: The design's success is tied to the parameters of the chosen fiber collimators (receiving angle and beam radius). Adapting it to different collimators would require recalculating the optimal sphere diameter.
  • Theoretical analysis focuses on first/second order: While higher-order reflections are discussed as being minimized, the detailed interference analysis primarily considers the first and second-order components.
  • Future work could explore:
    • Integration into actual micro-displacement sensing systems to demonstrate its practical performance.
  • Investigating the impact of different types of spherical surfaces or coatings.
  • Exploring the design's suitability for dynamic measurements.
  • Further optimization for even more compact or cost-effective implementations.

Summary updated

Abstract

Low-finesse Fabry–Perot (F–P) cavities, widely applied in the field of micro-displacement measurement, offer significant advantages in reducing the influence of higher-order reflections and improving the accuracy of measurement systems. Generally, an F–P cavity finesse of 0.5 is required to achieve high-precision micro-displacement measurements. However, in optical design, low-finesse cavities impose strict requirements on reflectivity, and maintaining fine stability during cavity movement is challenging. Achieving ideal orthogonal interference with a finesse of 0.5 thus presents considerable difficulties. This study proposes a novel low-finesse F–P cavity design that employs a high-reflectivity spherical reflector and the end face of a fiber collimator as the reflective surfaces of the cavity. By utilizing beam divergence characteristics and geometric parameters, a structure with a finesse of approximately 0.5 is quantitatively designed, enabling a simplified implementation without the need for angular alignment. Compared with conventional approaches, this method eliminates the need for precise angular alignment of the reflective surfaces, significantly simplifying implementation. The experimental results show that, under fixed receiving field angles and beam radii of the fiber collimators, ideal orthogonal interference can be achieved by selecting the radius of the reflective sphere. Under varying working distances, the average finesse values of the interference spectra measured by Collimators 1 and 2 are 0.496 and 0.502, respectively, both close to the theoretical design value of 0.5, thereby meeting the design requirements.