Introduction
Tunnels in cold regions are prone to "frozen damage," where cycles of freezing, thawing, and icing degrade concrete linings and jeopardize electrical systems. To mitigate these risks, engineers design freezing-proof systems such as insulation layers. However, the efficacy of these designs depends on accurate temperature data. Historically, obtaining this data has been difficult due to hardware failures in extreme cold and the low resolution of manual readings. This paper addresses these gaps through the development of specialized monitoring hardware and long-term in-situ data collection.
Methods: Hardware Innovation and Monitoring
The researchers developed a low-temperature automatic recorder specifically for harsh environments. The device features a specialized lithium battery and an "automatic wake-up" circuit. To conserve power, the recorder remains dormant, activating for only one second every hour to capture a reading. This design allows for up to 32,000 data points over six months on a single charge, maintaining an accuracy of 0.06°C even in sub-zero conditions.
These recorders were installed at depths ranging from 50m to 1500m within the Hongfu Tunnel in Shanxi Province, China. Monitoring spanned two years (2011–2013), capturing the thermal environment both before and after the tunnel's bi-directional excavation met in the middle—a milestone known as "breakthrough."
Key Insights: The Breakthrough Effect and Model Accuracy
The data revealed a dramatic shift in the tunnel's thermal behavior following breakthrough. Before the tunnel was fully hollowed out, the interior remained relatively insulated; sections deeper than 200m stayed above freezing even during winter. After breakthrough, the tunnel acted as a "wind chimney," allowing cold air to circulate freely and causing temperatures to plummet below 0°C throughout its entire length.
A critical finding of the study is the "danger of idealization." Engineers often use smooth sine waves to model annual temperature changes. However, the high-resolution data shows that actual fluctuations are far more volatile. Numerical simulations using measured data predicted a minimum temperature of -4.10°C, whereas simulations using a fitted sine wave predicted -2.65°C. This 1.45°C discrepancy is significant in engineering, as it could lead to under-designed insulation that fails during peak cold events.
Engineering Results and Applications
The study utilized the collected data to build a 2D Finite Element Method (FEM) model in ANSYS. Key findings include:
- Freezing Depth: The "freezing circle" extends approximately 1.5m into the surrounding rock.
- Heat Flux: A maximum heat flux of 36.08 W/m² was measured during the coldest months, indicating significant heat transfer from the rock to the tunnel air.
- Freeze-Thaw Cycles: The lining undergoes multiple cycles annually, particularly during transitional months (November, December, March, and April), which is more damaging than a single sustained freeze.
Based on these results, the authors validated that placing insulation layers on the second lining is the most practical solution for preventing frost damage in this environment.
Conclusion
While the study provides a robust framework for tunnel monitoring, it notes limitations such as the exclusion of groundwater seepage and latent heat in the FEM model. Future research should aim to create a broader thermal map for cold-region tunnels to account for varying geographies and airflow dynamics. Nevertheless, the high-resolution, in-situ approach demonstrated here offers a vital corrective to idealized models in geotechnical engineering.
Summary updated