Loading system for wind turbine drivetrain test bench withmodel-based compensation control strategy

Danyang Li, Yajing Gu, Yonggang Lin, Jiajun Song, Xiangheng Feng, Hongwei Liu2024

TL;DR

Testing massive wind turbine drivetrains on the ground requires simulating complex, high-force wind loads across five degrees of freedom. This paper introduces a multi-cylinder "digital-servo" loading system (MEDSL) and a model-based sliding mode control (SMC) strategy to eliminate the jarring force spikes and "eccentric moments" that occur when switching between high-power and high-precision hydraulic cylinders.

What Problem Does This Paper Address?

As wind turbines scale up to 15MW and beyond, the forces their drivetrains must withstand become astronomical. To ensure these components don't fail mid-ocean, engineers use ground-based test benches to replicate real-world wind conditions.

Replicating these loads is a balancing act. You need massive force (provided by large hydraulic cylinders) but also high precision to follow rapid wind fluctuations. A single large cylinder often lacks the agility needed for precision, so researchers use "Multi-cylinder Electrohydraulic Digital-Servo Loading" (MEDSL). This system groups several cylinders together: one "Servo-Valve Controlled" (SVC) cylinder for fine-tuning and several "On-Off Valve Controlled" (OVC) cylinders for the heavy lifting.

However, this setup introduces two major headaches:

  1. Eccentric Moments: Because the cylinders are grouped, the center of force shifts depending on which cylinders are active, creating unwanted twisting forces.
  2. Switching Glitches: Servo valves react much faster than on-off valves. When an OVC cylinder kicks in to add more force, there is a momentary "reverse sudden change" or lag that creates a massive error in the simulated load.

Methods

The authors propose a two-pronged solution:

  • A New Loading Principle: They derived a mathematical transformation matrix that recalculates the required force for every cylinder in real-time. This accounts for the physical installation distance and ensures that the "eccentric moment" is compensated for, keeping the 5-DOF (Degrees of Freedom) loads accurate.
  • Model-Based Sliding Mode Control (SMC): To fix the switching glitches, they moved away from traditional PID controllers. They developed a state-space model of the hydraulic system and implemented an SMC strategy. SMC is a robust nonlinear control technique that "slides" the system toward a desired state. Crucially, they included a saturation function to prevent "chattering"—the rapid, high-frequency oscillations often seen in basic SMC designs.

Datasets

The study relies on co-simulation rather than a physical dataset. The authors used AMESim (for high-fidelity hydraulic modeling) and Simulink (for the control logic). They evaluated the system using simulated sinusoidal wind load signals at frequencies of 0.2 Hz, 0.5 Hz, and 1.0 Hz to represent various dynamic wind conditions.

Key Insights and Ideas

  • The "Slow Down to Speed Up" Strategy: One of the most interesting findings was how the SMC handled the asynchronous valves. While a PID controller lets the total force drop rapidly before rebounding when an on-off valve opens, the model-based SMC actively slows down the servo valve's response to match the slower on-off valve. This "handshake" results in a much smoother total force curve.
  • Geometry Matters: The paper highlights that in multi-cylinder systems, the "loading center" is a moving target. By treating the loading radius and eccentricity as variables in a real-time matrix, they can maintain 5-DOF accuracy even as the hardware configuration changes.
  • Robustness over Simplicity: While PID is the industry standard for its simplicity, it fails to account for the nonlinear "pressure-flow" characteristics of hydraulic valves. The model-based approach succeeds because it "understands" the physics of the fluid power.

Key Results

The co-simulation results showed a clear victory for the SMC over traditional PID:

  • Error Reduction: In the 0.5 Hz test, the switching error was slashed from approximately 6.3 kN (with PID) down to 2.4 kN (with SMC).
  • Response Timing: Under PID control, the on-off valve took 20ms to respond while the servo responded in 3ms, causing a massive force dip. The SMC synchronized this by delaying the servo response to 9ms, smoothing the transition.
  • Tracking Precision: Outside of the switching moments, the tracking error for the SMC remained within 0.4 kN, whereas the PID error hovered around 1.4 kN.

Limitations and Future Work

  • Asymmetry in Direction: The authors noted that the switching error is larger during the "descending" process (reducing force) than the "ascending" process. This is due to the inherent differences in how valves open versus how they close, a problem they aim to solve in future iterations.
  • Scaling Complexity: This paper focused on a simplified case of one SVC and one OVC cylinder. Real-world test benches use many more. The authors plan to expand their research to a 12-point force application system, which will involve significantly more complex loading matrices and potential disturbances.
  • Physical Validation: The current results are purely simulation-based. The next logical step, though not detailed here, would be validating these controllers on a physical MW-class test rig.

Summary updated

BibTeX
@misc{li2024loading,
  author = {Danyang Li and Yajing Gu and Yonggang Lin and Jiajun Song and Xiangheng Feng and Hongwei Liu},
  title = {{Loading system for wind turbine drivetrain test bench withmodel-based compensation control strategy}},
  year = {2024},
  doi = {10.13052/rp-9788770047975.021},
}