Abstract: When transient flow occurs in the liquid pipeline, it will result in higher water hammer pressure or negative pressure in pipeline, thus damaging pipeline. Through the establishment of liquid pipeline transient flow mathematical model which is solved by characteristic linear method, and by getting difference quotient equation of characteristic equation by explicit characteristic difference method, we can obtain analytical solutions of each transient flow parameters. After performing numerical simulation for pump start-up working condition, the result shows that the proposed model approach in this paper is feasible.
Introduction
In midstream oil and gas operations, pipelines rarely maintain a perfectly steady state. Transient flow—sudden changes in pressure and velocity—occurs whenever a pump starts, a valve closes, or a leak develops. The primary risk is the "water hammer" effect: rapid pressure waves that can exceed structural limits, causing catastrophic failure or equipment damage. Conversely, sudden pressure drops can create vacuums that collapse pipes. Accurate modeling of these fast transient events is essential for safe pipeline design and operation.
Methodology
The fluid movement is modeled as a one-dimensional flow problem governed by the conservation of mass, momentum, and energy. To solve these partial differential equations (PDEs), the research employs the Method of Characteristics (MOC). This technique transforms the PDEs into ordinary differential equations (ODEs) valid along specific paths, or characteristic lines, in the time-space domain.
An Explicit Characteristic Difference Method was selected for its suitability in modeling "fast transients" where parameters change rapidly over short time steps. By using central difference quotients and adhering to the Courant-Friedrichs-Lewy (CFL) stability criteria, the model ensures numerical stability while calculating pressure ($P$), flow velocity ($v$), and temperature ($T$).
Case Study and Results
The model was validated using a numerical case study of a centrifugal pump start-up. The system comprised a 1,500m suction line and a 10km outlet line (273mm diameter). The simulation tracked the transition from a steady state to an operating flow of 0.1 m³/s.
Key findings include:
- Pressure Spikes: Upon start-up, the pump outlet pressure does not rise linearly. It spikes to a maximum head of 248m before stabilizing at approximately 156m. This highlights that the peak surge pressure, rather than the final operating pressure, often poses the greatest risk.
- Spatial Lag: There is a clear time lag in pressure and flow fluctuations between the suction port, the outlet port, and points further downstream (e.g., 9km away), illustrating the propagation of the pressure wave through the fluid.
- Thermal Integration: By coupling the energy equation, the model tracks temperature changes, which is critical as temperature fluctuations alter fluid density and viscosity.
Conclusion
The simulation results confirm that the explicit characteristic difference method provides a stable and physically accurate representation of real-world pipeline behavior. This mathematical framework offers a reliable tool for engineers to predict and mitigate the risks associated with transient flow and water hammer effects in liquid pipelines.
Summary updated