NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Leveraging Fast Healthcare Interoperability Resources (FHIR) for the Exchange of Wearable Inertial Sensor Data: Design and Development Study

Gabriela Ciortuz, Joshua Wiedekopf, Hannes Ulrich, Hawzhin Hozhabr Pour, Sebastian FudickararXiv 2026

TL;DR

Wearable sensors capture the rhythm of our daily lives, but their data is currently trapped in proprietary silos that doctors can't easily read. This paper introduces WHIR (Wearable Health Interoperable Recordings), a clever framework that uses the FHIR healthcare standard to exchange long-term motion data and activity labels, finally bridging the gap between raw sensor streams and clinical health records.

What Problem Does This Paper Address?

We are living in an era of "quantified self," where smartphones and body-worn sensors—specifically Inertial Measurement Units (IMUs) containing accelerometers and gyroscopes—can track disease progression, frailty, and neurological disorders with incredible precision.

The catch? This data is a mess. Every device manufacturer has its own proprietary file format. If a researcher wants to use data from three different studies, they have to write three different parsers. Even worse, these raw data files rarely make it into Electronic Health Records (EHRs) because the current standard for health data exchange, FHIR (Fast Healthcare Interoperability Resources), wasn't designed for them.

Existing FHIR profiles are great for "spot checks" (like a single blood pressure reading) or short waveforms (like a 10-second ECG), but they choke on hours of multi-channel sensor data sampled at 100Hz. Furthermore, the context—where the sensor was placed and what the patient was actually doing (the "activity labels")—is often lost or stored in a separate, disconnected spreadsheet.

Methods

The authors developed WHIR to act as a standardized "envelope" for this data. Their approach followed a logical three-step process:

  1. Requirement Analysis: They reviewed 23 public Human Activity Recognition (HAR) datasets to identify exactly what metadata is needed to make sense of a recording (e.g., sampling rate, body placement, sensor type).
  2. Information Modeling: They built a FHIR-independent model first to ensure it made sense to domain experts (see Figure 2).
  3. FHIR Mapping: They mapped this model to the latest version of the standard, FHIR R5.

The "secret sauce" of WHIR is its hybrid storage strategy. Instead of trying to shove millions of raw data points directly into a FHIR resource (which would bloat the database and slow down queries), WHIR keeps the raw signals in simple, external files (like CSVs). The FHIR resources then act as a metadata layer, using DocumentReference to point to the raw data while holding the "meaning"—the sensor placement, device configuration, and time-aligned activity labels (e.g., "Patient started walking at 10:05:02").

Figure 2. Information model for wearable sensor data.

Datasets

To ensure WHIR was grounded in reality, the authors analyzed 23 published HAR datasets, including well-known benchmarks like:

  • Daphnet: Focused on Parkinson’s freezing of gait.
  • PAMAP2: Physical activity monitoring.
  • UCI HAR: A classic smartphone-based activity dataset.
  • REALDISP: Highlighting the challenges of sensor displacement.

These datasets varied wildly in their characteristics, as shown in Figure 1, which helped the authors create a flexible standard that works whether you have one sensor or twelve.

Figure 1. Characteristics of the 23 reviewed IMU-based HAR datasets by application area: number of activity classes, body-worn IMU devices, body placements, and sampling rate (log scale). Boxes show the interquartile range (IQR) with the median (bar); whiskers extend to 1.5 × IQR; dots are outliers. Datasets that do not report a sampling rate are omitted from that column.

Key Insights and Ideas

  • Context is King: An accelerometer signal is just a bunch of numbers unless you know it was on the right ankle and the patient was climbing stairs. WHIR makes this link explicit and searchable.
  • Don't Break the Server: By referencing external files rather than embedding data, WHIR allows FHIR servers to remain efficient "indices" of health events rather than struggling to act as massive time-series databases.
  • Standardized Vocabulary: The authors didn't reinvent the wheel. They mapped sensor placements and activities to existing clinical terminologies like SNOMED CT and LOINC, ensuring that "walking" in a sensor file means the same thing as "walking" in a doctor's note.
  • The Current Mess: Table 1 in the paper highlights the status quo: a fragmented landscape where units, rates, and labels are scattered across readmes, headers, and external files. WHIR consolidates this.
Table 1. Sensors, sampling rate, data collection and output, and storage of activity labels for four wearable IMU devices: two devices from our own studies and the devices used in two public HAR datasets from the review. For PAMAP2 and UCI HAR, the output describes the published dataset.

Key Results

  • Technical Validation: The WHIR Implementation Guide (IG) defines 9 profiles and 4 extensions. All artifacts and 67 example instances passed the official HL7 FHIR conformance checks with zero errors.
  • Use Case 1 (Machine Learning): They demonstrated how WHIR can represent complex training data where multiple sensors (e.g., a belt and a smartphone) are used simultaneously with expert-supervised labels.
  • Use Case 2 (Clinical Assessment): They showed how a home-based "Timed Up and Go" (TUG) test can be automatically analyzed by software, with the results flowing directly into a FHIR-based diagnostic report and care plan.

Limitations and Future Work

While WHIR is a major step forward, the authors note a few hurdles:

  • Operational Interoperability: While the model is technically correct, it hasn't been tested in a "live" exchange between two different commercial systems yet.
  • FHIR Versioning: WHIR uses FHIR R5, but many hospitals are still on the older R4. A "backport" might be necessary for immediate adoption.
  • Beyond IMUs: The current version focuses on motion, but future iterations could expand to other wearables like mobile brain imaging (fNIRS) or heart rate monitors.
  • Performance: The efficiency of querying thousands of individual "activity label" resources across a large population remains to be measured.

Summary updated

BibTeX
@misc{ciortuz2026leveraging,
  author = {Gabriela Ciortuz and Joshua Wiedekopf and Hannes Ulrich and Hawzhin Hozhabr Pour and Sebastian Fudickar},
  title = {{Leveraging Fast Healthcare Interoperability Resources (FHIR) for the Exchange of Wearable Inertial Sensor Data: Design and Development Study}},
  year = {2026},
  eprint = {2611.30956},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.30956},
}
Figure