LesionAgent: Training-Free Agentic Tumor Tracking and Response Assessment in Longitudinal CT

Maximilian Rokuss, Jeya Maria Jose Valanarasu, Alejandro Lozano, Benjamin Hamm, Yannick Kirchhoff, Fabian Isensee, Klaus Maier-HeinarXiv 2026 · arXiv

Imagine you’re a radiologist. Every few months, you’re handed a stack of CT scans for a cancer patient. Your job isn’t just to find a tumor; it’s to play a high-stakes game of "spot the difference" across months or years. You have to find the same tiny nodules, measure them precisely, decide if a new shadow is a growing malignancy or just a scar from radiation, and then apply a dense 30-page rulebook called RECIST 1.1 to decide if the treatment is working.

It’s tedious, it’s complex, and even experts disagree with each other about 60% of the time on which lesions to track. While we have AI models that are great at seeing (segmenting a lung) or finding (detecting a nodule), we haven't had an AI that can reason through the entire longitudinal process—until now.

TL;DR

LesionAgent is a training-free AI agent that performs end-to-end tumor tracking and response assessment in CT scans. By using a Large Language Model (LLM) as a "brain" to orchestrate specialized 3D vision tools, it follows clinical guidelines with a level of reasoning and self-verification that far surpasses standard automated pipelines.

What Problem Does This Paper Address?

The core challenge in oncology imaging is longitudinal assessment. A single snapshot isn't enough; you need the whole movie. Current "foundation models" for medical imaging are specialized: one might be great at segmenting a liver, another at registering (aligning) two scans. However, they are "silent failers"—they might confidently segment a blood vessel instead of a tumor, and a fixed computer program wouldn't know the difference.

Furthermore, the clinical standard, RECIST 1.1 (Response Evaluation Criteria in Solid Tumors), is a logic-heavy framework. It requires choosing "target" lesions, ignoring "non-target" ones, and making nuanced judgments about whether a new spot is "unequivocally" progression. Standard AI lacks the "common sense" to navigate these rules, often leading to "false progressions"—falsely claiming the cancer is getting worse when the AI just made a tracking error.

Methods

The authors introduce an agentic loop. Instead of training one giant model to do everything, they took off-the-shelf LLMs (like Claude 3.5 or Qwen) and gave them a "harness" to act as a digital radiologist.

The LesionAgent architecture: An LLM orchestrates 3D tools, maintains a registry, and uses a deterministic engine for final assessment.

Key components of the "harness" include:

  • 3D Foundation Tools: The agent can call specialized models to detect, segment, register, and track lesions.
  • Coordinate-Labeled Views: The LLM doesn't just see a raw image; it sees 2D slices with absolute 3D voxel coordinates. This allows it to "click" on a specific spot to ask for a better segmentation or to verify a finding.
  • The Lesion Registry: A persistent memory that tracks every lesion's ID, organ, and measurements across every visit.
  • Self-Verification: This is the "aha" moment. If a model segments a tumor, the agent doesn't just trust it. It might ask for a "second opinion" from a different model or check if the volume changed by an impossible amount (e.g., tripling in size in two days), flagging it for review if something looks fishy.
  • Deterministic Guideline Engine: The LLM is the judge, but not the calculator. It identifies the lesions, and then a hard-coded "engine" applies the mathematical RECIST rules to ensure the final "Stable Disease" or "Progression" label is mathematically perfect.

Datasets

The researchers evaluated LesionAgent on four public longitudinal CT datasets:

  1. HCUCH: Clinical RECIST 1.1 measurements from 14 patients.
  2. TumorMap-Lung: 33 lung cancer patients with expert contours.
  3. PanTrack: 15 patients focused on pancreatic tumors.
  4. NCI-MATCH: Data from a major clinical trial.
  5. DeepLesion DLS: A benchmark for tracking 960 lesion pairs.
  6. LIDC-NLST501: Screening CTs used to compare the agent against 20 human radiologists.

Key Insights and Ideas

  • The Harness is the Hero: The researchers found that the LLM's "intelligence" isn't enough on its own. When they gave the same LLM the images but took away the "harness" (the registry and verification tools), performance plummeted. For an open-weight model like Qwen, the detection F1 score jumped from a measly 6% to 73% just by putting it inside the LesionAgent harness.
  • Catching Silent Failures: 3D models often "drift" onto neighboring structures. LesionAgent catches this by comparing the new scan to the baseline. If a "new" lesion appears exactly where a missed lesion was at baseline, the agent realizes it’s not new—it’s just a tracking error.
  • Human-in-the-Loop: The system is designed to be collaborative. It can ask a clinician: "I found two possible target sets; one says the patient is stable, the other says they are progressing. Which do you prefer?"
LesionAgent vs. human radiologists: The agent measures nodules as accurately as experts, though it is slightly more conservative in finding the smallest ones.

Key Results

  • Clinical Accuracy: On clinical follow-up CTs, LesionAgent agreed with radiologists' treatment response at 20 of 23 follow-ups, including every single case where the response category changed.
  • Reducing False Alarms: In cases where a standard "fixed" AI pipeline falsely called "progression" 33 times, LesionAgent—using the exact same underlying 3D models—only made that mistake twice.
  • Zero-Shot Champion: Without any specific training on the DeepLesion dataset, it outperformed every specialized tracker that was trained on it, achieving an 89.0% recall.

Limitations and Future Work

  • Small Lesion Gap: While the agent is as accurate as a radiologist for lesions over 10mm, it still lags behind humans in detecting very small nodules (under 6mm).
  • Model Dependency: The agent is only as good as its tools. If the underlying 3D detection model misses a tumor entirely, the agent might not know to look there unless it performs a manual "sweep."
  • Computational Cost: Running an agentic loop with multiple tool calls and LLM reasoning steps is slower and more expensive than a simple feed-forward neural network.

In short, LesionAgent suggests that the future of medical AI isn't just bigger models, but smarter systems that can reason, remember, and double-check their own work.

Summary updated

Abstract

Every few months, a cancer patient's CT scans decide whether treatment continues. 3D foundation models can now detect, segment, register and track lesions, yet none of them reads the scans as a radiologist does. A radiologist decides which findings are lesions, which are the same lesion months later and whether a new spot means progression, and checks each decision against the extensive rules of a clinical guideline. We introduce LesionAgent, an LLM agent that performs this read end to end without task-specific training. It operates frozen 3D models as tools, acts in 3D through coordinate-labelled views, remembers every lesion across visits in a registry, verifies every model output it relies on, and leaves every number to a deterministic guideline engine. On four public longitudinal CT datasets, LesionAgent tracks more lesions and measures them more accurately than every automatic baseline, and where the same 3D models chained by fixed rules call progression falsely at 33 of 56 follow-ups, it does so twice. On clinical follow-up CTs, it agrees with the radiologists' response at 20 of 23 follow-ups, including every change in response, and without training on DeepLesion, it retrieves more of its lesions than every tracker trained on it (89.0% vs. 87.4%). Its harness, not its LLM, makes the difference: given the same LLM and 3D models but not the harness, Claude Code reaches a detection F1 of 41% and LesionAgent 78%, and an open-weight LLM that can run inside the hospital rises from 6% to 73%. LesionAgent and a napari reading app for any LLM are available at https://github.com/MIC-DKFZ/LesionAgent.
BibTeX
@misc{rokuss2026lesionagent,
  author = {Maximilian Rokuss and Jeya Maria Jose Valanarasu and Alejandro Lozano and Benjamin Hamm and Yannick Kirchhoff and Fabian Isensee and Klaus Maier-Hein},
  title = {{LesionAgent: Training-Free Agentic Tumor Tracking and Response Assessment in Longitudinal CT}},
  year = {2026},
  eprint = {2611.27876},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.27876},
}
Figure