Learning to Tune with Biased Gradients: Iterative Feedback Tuning of Model-Free Control on Throttle Valves

Félix Martinez-Jiménez, Sander Miller-Murphy, Tobie Ondoa-Essomba, Emmanuel WitrantarXiv 2026 · arXiv

This paper explores the practical challenges of using Iterative Feedback Tuning (IFT)—a data-driven method for optimizing controllers—on mechanical systems plagued by non-linearities like friction and stiction. The authors demonstrate that while modern machine learning optimizers like Adam can help navigate noisy gradients, they can also lead to "drift" and performance degradation when the underlying gradient estimation is biased by the physics of the plant.

TL;DR

Iterative Feedback Tuning (IFT) fails to provide unbiased gradients for non-linear systems because stiction prevents the system from starting in the same state for consecutive experiments. While adaptive optimizers like Adam can mitigate noise in some hardware units, they can also amplify biased directions in others, making experiment design more critical than the choice of update rule.

What Problem Does This Paper Address?

In control engineering, tuning a controller often involves minimizing a cost function $J(\vartheta)$ based on experimental data. IFT is a popular "model-free" approach that estimates the gradient of this cost by running two consecutive closed-loop experiments on the physical plant.

The catch? IFT is mathematically guaranteed to be unbiased only for linear time-invariant (LTI) systems. Real-world mechanical systems, like the automotive electronic throttle valves (ETVs) studied here, are far from linear. They suffer from stiction (static friction), which means the valve can get "stuck" at slightly different positions. This creates an initial-state mismatch between the two experiments required for IFT, introducing a systematic bias into the gradient estimate. The authors set out to quantify this bias and see if modern optimization tricks from the machine learning world (like Adam) can fix it.

Methods

The researchers focused on an intelligent proportional (iP) controller, which effectively acts as an incremental PI controller. They compared several update rules for stochastic gradient descent:

  • Gauss-Newton (GN): The standard IFT update rule.
  • Adam: A popular ML optimizer that uses coordinate-wise normalization and momentum.
  • Sign-SGD: An update rule that only considers the sign of the gradient.

To study these, they developed digital twins of ten different throttle valves, identified from real-world data using differential evolution. These twins allowed them to perform "ablation studies"—turning off specific non-linearities (like friction or saturation) to see exactly what causes the gradient bias.

Datasets

The study utilized:

  • Digital Twins: Models of 10 throttle valves identified from PRBS (Pseudo-Random Binary Sequence) and PWM staircase data.
  • Hardware Benchmarks: Real-time experiments conducted on two specific physical valves (Valve A and Valve B) using an Arduino-based setup.
  • Validation Protocol: A 15/65° square reference tracking task used to evaluate the final performance of the tuned controllers.

Key Insights and Ideas

  • The Stiction Bias Formula: The authors prove (Proposition 1) that the gradient error caused by stiction is inversely proportional to the amplitude $c$ of the second experiment. This is a crucial "aha moment": while standard theory suggests small perturbations for gradients, in the presence of stiction, small experiments actually amplify the bias.
  • Friction is the Culprit: By testing their digital twins, the authors found that removing input saturation or damping asymmetry barely improved gradient reliability. However, removing Coulomb friction and stiction restored the "descent fraction" (the probability that the gradient actually points toward a lower cost) from 69% to nearly 100%.
Ablation study showing that friction is the primary cause of low descent fractions.
  • Adam is a Double-Edged Sword: Adam’s coordinate-wise normalization helps when one parameter's gradient is buried in noise (as seen in Valve A). However, if both parameters have consistent but biased gradients (as in Valve B), Adam can amplify a "bad" direction that Gauss-Newton would have rightly ignored, leading the controller to drift into a worse state than where it started.

Key Results

  • Gradient Reliability: On digital twins, the IFT gradient was a valid descent direction in only 69% of the low-cost region.
  • Hardware Performance:
    • Valve A: Adam outperformed Gauss-Newton. GN's metric discounted a reliable direction, while Adam's normalization "freed" it, reducing validation RMSE from ~7.2° to ~6.7°.
  • Valve B: The ranking reversed. Adam drifted to a controller worse than the hand-tuned original (RMSE rose to 7.46°), while GN converged to a stable, improved setting (RMSE 6.71°).
  • Stopping Rules: Because the IFT cost itself is noisy and biased, it cannot be used to decide when to stop tuning. A separate validation test is indispensable to prevent the "drift" observed in later iterations.
Hardware tuning trajectories showing Adam's success on Valve A vs. its drift on Valve B.

Limitations and Future Work

The study is limited to a small number of hardware units (two valves), and the theoretical results currently only cover constant offsets. The authors note that their digital twins, while useful for understanding mechanisms, failed to predict which optimizer would perform best on a specific piece of hardware.

Future work suggests exploring Bayesian Optimization as a gradient-free baseline or developing friction-aware estimators (e.g., using dithering or repeated settling) to explicitly correct the bias identified in this paper.

Summary updated

Abstract

Iterative feedback tuning (IFT) learns the parameters of a fixed-structure controller by stochastic gradient descent. At each iteration, two closed-loop experiments are run on the plant: the first one measures the tracking error, and the second one, driven by this error, provides the sensitivities from which the gradient of the cost is estimated. This estimate is unbiased for linear plants only. We study the biased case on automotive electronic throttle valves, whose friction and stiction vary between valves and runs, controlled by an intelligent proportional (model-free) controller, which is an incremental PI controller. We show that the mismatch of the controller state at the start of the two experiments, which stiction makes unavoidable, adds an error inversely proportional to the amplitude of the second experiment. On digital twins of ten valves, the IFT gradient is a descent direction in only 69\% of the low-cost region, friction being the cause, and all update rules plateau and then drift. On two hardware valves, the best update rule depends on the noise structure of the gradient. On the first valve, where one gradient component is buried in noise, Adam outperforms Gauss--Newton, its normalisation and its momentum each improving one parameter. On the second valve, where both components are consistent, the same normalisation amplifies a direction that Gauss--Newton rightly discounts, and Adam drifts to a controller worse than the initial one. The twins reproduce the mechanism but not this ranking.
BibTeX
@misc{martinezjimenez2026learning,
  author = {Félix Martinez-Jiménez and Sander Miller-Murphy and Tobie Ondoa-Essomba and Emmanuel Witrant},
  title = {{Learning to Tune with Biased Gradients: Iterative Feedback Tuning of Model-Free Control on Throttle Valves}},
  year = {2026},
  eprint = {2611.06338},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.06338},
}
Figure