NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Leakage-Safe Auditing of Attribution-Driven Data Curation in Medical Imaging

Malay Phadke, Akshay GokhalearXiv 2026

It’s late, you’ve spent all day looking at dashboards or debugging pipelines, and you just want to know: if my AI model is looking at the "wrong" part of an image, should I just delete that image from my training set?

Common sense says yes. But a new paper from researchers at the Sardar Patel Institute of Technology suggests that in the high-stakes world of medical imaging, common sense might be leading us astray. Their work, "Leakage-Safe Auditing of Attribution-Driven Data Curation in Medical Imaging," is a sobering look at why "cleaning" your data based on AI heatmaps is a lot harder than it looks.

TL;DR

Just because an attribution map (like a heatmap) shows a model is "confused" by an image doesn't mean that image is harming the model's learning. The researchers found that even when they identified objectively "corrupted" data (totally blank images labeled as positive), removing them actually decreased model performance, proving that "anomaly detection" is not the same thing as "intervention utility."

What Problem Does This Paper Address?

In medical AI, we often use attribution maps—tools like GradCAM++ that highlight which pixels a model focused on to make a decision. If a model identifies an aneurysm but the heatmap is glowing in a corner of the image where there’s nothing but black space, we call that an anomaly.

The standard workflow is:

  1. Generate a heatmap.
  2. See something weird.
  3. Delete that "bad" data to "clean" the dataset.

The authors argue this workflow conflates three very different claims:

  • Anomaly Detection: Is this sample unusual?
  • Harmfulness Estimation: Is this sample actually making the model worse?
  • Intervention Utility: Will deleting it actually make the model better?

Furthermore, medical imaging has a "leakage" problem. A single patient might provide dozens of image "patches." If you aren't careful, you might train on one patch from Patient A and test on another patch from Patient A, leading to artificially inflated scores. This paper audits a curation pipeline to see if these attribution-based "fixes" actually hold up under strict, leakage-safe conditions.

Methods

The researchers audited a 3D Convolutional Neural Network (a MONAI ResNet-10) designed to find intracranial aneurysms in CT scans.

Key aspects of their audit included:

  • Patient-Disjoint Splitting: Ensuring that no patient’s data appeared in both the training and testing sets.
  • The Three-Claim Framework: They treated "detecting a weird image" and "improving the model by deleting it" as two separate hypotheses to be tested.
  • Attribution Comparison: They compared two popular methods—GradCAM++ and Integrated Gradients (IG)—to see if they even agreed on what constituted an "anomaly."
  • Budget-Matched Controls: When they removed "bad" samples, they also ran a control experiment where they removed the same number of random samples to ensure any change in performance wasn't just due to having a smaller dataset.

Datasets

The study used the RSNA 2025 Intracranial Aneurysm Detection Challenge dataset. This is a massive, multi-institutional collection of CTA (Computed Tomography Angiography) scans.

  • Total Patches: 7,742
  • Positive Patches: 1,201
  • Negative Patches: 6,541 (divided into "Frangi," "Hard," and "Easy" negatives).

Key Insights and Ideas

  • The "Raw-Zero" Mystery: The audit discovered 232 positive patches that were literally just empty, zero-valued arrays. These are objectively "corrupted" data points. You’d think removing them would be an easy win for model accuracy.
  • Attribution Disagreement: For positive samples, GradCAM++ and Integrated Gradients actually showed a negative rank-order agreement (Spearman $\rho = -0.200$). In plain English: the two most common ways to "explain" an AI's decision couldn't even agree on which images were the most anomalous. This makes "method-independent" interpretation almost impossible.
Table 1: Showing the disagreement ($\rho$) between attribution methods.
  • The Deletion Paradox: Removing the 170 corrupted "zero" patches from the training set didn't help. In fact, the model trained on the "clean" data performed slightly worse than the one trained on the "dirty" data. This suggests that even "garbage" data might be providing some form of regularization or signal that we don't fully understand yet.

Key Results

The quantitative results were a reality check for the "clean the data" crowd:

  • Full Data Training: Achieved an AUC of $0.9652 \pm 0.0039$.
  • Strict Removal (Deleting Zeros): The AUC dropped to $0.9617 \pm 0.0044$.
  • Random Removal Control: Deleting a random set of 170 positives resulted in an AUC of $0.9565 \pm 0.0056$.
Figure 1: Training loss and Validation FPR@90 trajectories for the different conditions.

While the "Strict Removal" was better than "Random Removal," it still couldn't beat the original "dirty" dataset. The researchers also found that the "zero" patches were mostly associated with very small lesions (under 3mm), suggesting a failure in the data extraction process rather than the model's logic.

Table 2: Summary of performance across training conditions.

Limitations and Future Work

The authors are careful to note that this was a retrospective audit of a specific pipeline.

  • Scope: They only looked at one model architecture (ResNet-10) and one disease (aneurysms).
  • Missing Links: They didn't directly test the "harmfulness" link—i.e., why these zero-patches didn't degrade the model more significantly.
  • Future Directions: They suggest that future work should focus on "influence functions" or "leave-one-out" analyses to truly isolate how individual samples affect the learned representations.

The takeaway? Attribution maps are great for telling you where to look, but they shouldn't be the final judge of what stays in your training set. Data curation requires a much more rigorous, multi-step proof than just "this heatmap looks weird."