Judgement and Calculation of Trend of Corrosion and Scaling of Geothermal Water

Tao YaoIndustrial 2004

Abstract

The phenomena of corrosion and scaling may occur in the operation of geothermal water heat-supply system. Usually, the trend of corrosion and scaling by geothermal water is expressed by Ryznar index. It is shown by engineering practice that when the value of the milligram equivalent percentage of Cl- in geothermal water exceeds 25%, the use of Ryznar index for the judgement has some limitations and, in this case, it is necessary to take into consideration the Larson index in judging water quality, which is the only way to make the judgement accord with the actual conditions.
BibTeX
@inproceedings{yao2004judgement,
  author = {Tao Yao},
  title = {{Judgement and Calculation of Trend of Corrosion and Scaling of Geothermal Water}},
  booktitle = {Industrial},
  year = {2004},
}