NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Joint Constraints Based Dynamic Calibration of IMU Position on Lower Limbs in IMU-MoCap

Qian Hu, Lingfeng Liu, Feng Mei, Changxuan Yang2021

TL;DR

This paper introduces a dynamic calibration method for Inertial Measurement Units (IMUs) placed on lower limbs during motion capture. By leveraging joint constraints and comparing three algorithms (Gauss-Newton, DWPSO, and GWO), they demonstrate improved accuracy in estimating joint angles, crucial for applications like sports analysis and rehabilitation.

What Problem Does This Paper Address?

Accurate human motion capture is vital for fields like sports science and rehabilitation. Inertial Measurement Units (IMUs) offer a cost-effective and flexible alternative to optical systems. However, IMUs mounted on the body can shift during movement, leading to significant errors in calculated joint angles. Existing calibration methods often require static poses or specific, sometimes difficult, motions, and can be sensitive to magnetic interference. This paper addresses the challenge of accurately calibrating IMU positions dynamically during natural movements, specifically focusing on lower limb joints, to overcome the limitations of static calibration and the inaccuracies introduced by IMU displacement.

Methods

The core of this work lies in a dynamic calibration algorithm that utilizes joint constraints. The authors propose and compare three algorithms for this task:

  • Gauss-Newton (GN): A traditional optimization method that uses the Jacobian matrix to iteratively refine IMU positions. The paper highlights its limitations, particularly when joint motion is restricted or not fully utilized, which can lead to a singular Jacobian matrix and algorithm non-convergence.
  • Dynamic Weight Particle Swarm Optimization (DWPSO): An enhanced particle swarm optimization algorithm. It introduces a dynamic weight that adjusts over iterations, aiming to balance exploration and exploitation for better convergence and to avoid local optima. This method does not rely on Jacobian matrix calculations, making it potentially more robust.
  • Grey Wolf Optimizer (GWO): Another population-based optimization algorithm inspired by wolf hunting behavior. It iteratively updates the positions of "wolves" (potential solutions) based on the positions of the best three individuals in the pack, aiming to find the optimal IMU positions.

The calibration process involves establishing a human lower limb coordinate system and using quaternion fusion to improve the attitude estimation of individual IMUs. The algorithms are then applied to estimate IMU positions based on joint constraints derived from accelerometer and gyroscope data.

Datasets

The study uses data collected from three human subjects (one female, two males of varying heights) performing walking motions. The IMUs were placed in two different positions on the lower limbs for each subject to assess the robustness of the calibration. High-precision IMU-Mocap equipment (Perception Neuron Pro) was used as a reference system for synchronous data acquisition and validation. No new benchmark datasets were introduced; rather, existing motion capture technology was leveraged for ground truth.

Key Insights and Ideas

  • Dynamic Calibration is Crucial: Static calibration is insufficient for IMUs during motion due to inevitable displacement. Dynamic calibration, accounting for movement, is essential for accurate motion capture.
  • Joint Constraints are Powerful: Leveraging the inherent kinematic constraints of human joints significantly improves the accuracy of IMU position estimation.
  • Population-Based Optimizers Outperform GN in Certain Scenarios: DWPSO and GWO demonstrated superior performance over the Gauss-Newton method, especially when joint motion was limited or not fully utilized. This is attributed to their ability to avoid issues with Jacobian matrix singularity that plague GN.
  • DWPSO Offers a Good Balance: While GWO is faster, DWPSO shows better stability and calibration performance, making it a strong candidate when accuracy is prioritized over speed.
  • IMU Displacement is a Fixed Offset: The study suggests that IMU position offset errors are relatively fixed over time during a specific motion, which is a valuable insight for future error correction strategies.

Key Results

  • All three algorithms (GN, DWPSO, GWO) successfully calibrated IMU positions and estimated joint angles during gait.
  • DWPSO consistently achieved the lowest Root Mean Squared Error (RMSE) across subjects and positions, indicating the highest accuracy compared to the reference motion capture system.
  • GWO was the fastest algorithm, followed by DWPSO, with GN being the slowest.
  • When joint motion was sufficient, the performance of all three algorithms was comparable. However, when joint rotation was insufficient (e.g., certain degrees of freedom in hip, knee, or ankle), DWPSO and GWO significantly outperformed GN.
  • Bland-Altman analysis confirmed that DWPSO provided the highest consistency with the reference values for hip abduction/adduction (HAA) and knee intra/extra rotation (KIE).

Limitations and Future Work

  • Computational Complexity of DWPSO: While DWPSO offers better accuracy, the introduction of dynamic weights increases its computational complexity compared to a standard PSO, potentially reducing efficiency.
  • Whole-Body Calibration: The current work focuses on lower limbs. Extending this to whole-body calibration presents a challenge, as a large amount of data might decrease the searchability of DWPSO and GWO.
  • Slow IMU Drift: The paper suggests future work could explore combining accelerometers and gyroscopes to estimate knee joint axes and further improve calibration accuracy, particularly when IMU position drifts slowly over time.
  • Further Experiments: The authors plan to conduct more experiments to validate their findings.

Summary updated

BibTeX
@misc{hu2021joint,
  author = {Qian Hu and Lingfeng Liu and Feng Mei and Changxuan Yang},
  title = {{Joint Constraints Based Dynamic Calibration of IMU Position on Lower Limbs in IMU-MoCap}},
  year = {2021},
  doi = {10.3390/s21217161},
}
Figure