Is Dataset Quality Still a Concern in Diagnosis Using Large Foundation Model?

Ziqin Lin, Heng Li, Zinan Li, Huazhu Fu, Jiang LiuarXiv 2024 · DOI

Introduction

While Large Foundation Models (LFMs) are revolutionizing medical imaging, recent research reveals they are not a "silver bullet" for poor data quality. This paper investigates the robustness of RETFound, a prominent foundation model for retinal images, against traditional convolutional neural networks like ResNet. While RETFound proves significantly more resilient to blurry or low-quality images, it remains highly susceptible to dataset bias—meaning rare diseases are still easily misdiagnosed when image quality drops.

In clinical reality, fundus (eye) cameras are often out of focus, lighting is inconsistent, or patients may have cataracts that obscure the view. Historically, these quality issues have crippled AI performance. This study explores whether the generalized features learned by LFMs during massive-scale pre-training allow them to naturally ignore such noise.

Methods

The researchers focused on RETFound, a Vision Transformer (ViT) architecture pre-trained on 1.6 million unlabeled fundus images. They compared its performance against a standard ResNet baseline using three adaptation strategies:

  • Linear Probe: Training only the final classification layer while keeping the LFM backbone frozen.
  • Overall Fine-tuning: Updating every parameter in the model.
  • Tip-Adapter: A training-free adaptation method.

Datasets and Quality Assessment

The study utilized two specialized fundus image datasets that include both disease labels and image quality grades:

  • EyeQ: 28,785 images categorized into High, Usable, and Low quality levels across five grades of Diabetic Retinopathy (DR).
  • iSee: 9,789 images categorized into High and Low quality levels across five disease categories, including Glaucoma and Age-related Macular Degeneration (AMD).
Figure 1: EyeQ dataset samples and distribution across quality levels and DR grades. Note the extreme class imbalance, particularly in early-stage disease (DR-1).

Key Results and Discussion

The Robustness Gap

RETFound consistently outperformed ResNet as image quality degraded. In the EyeQ dataset, RETFound’s AUROC dropped from 0.865 (high quality) to 0.803 (low quality). While this represents a decline, it was significantly more stable than the ResNet baseline, which saw a much sharper performance drop.

Figure 4: Performance comparison (AUROC) between RETFound and ResNet on the EyeQ dataset across varying quality levels.

Bias: The Achilles' Heel

Despite its robustness, the LFM still struggles with "minority" classes. In the EyeQ dataset, DR-1 (early-stage disease) is rare. When image quality dropped, the model's performance on DR-1 plummeted because it was frequently misclassified as the much more common DR-0 (healthy) or DR-2 (moderate) classes. This suggests that while LFMs handle noise better, they do not inherently solve the problem of class imbalance.

Fine-tuning Strategy

One of the most critical findings was that "overall fine-tuning" is essential for mitigating the impact of poor image quality. While linear probing is computationally cheaper, the model needs to adjust its internal representations to handle the specific noise patterns of real-world clinical data. Conversely, the training-free Tip-Adapter method failed entirely, likely due to the extreme class imbalance characteristic of medical datasets.

Conclusion

Foundation models like RETFound offer a significant step forward in clinical AI robustness, maintaining higher diagnostic accuracy under poor imaging conditions than traditional models. However, dataset quality and class bias remain major concerns. Future research must focus on "bias-aware" fine-tuning techniques to protect minority classes from the performance-crushing effects of image degradation. While LFMs are smarter, the quality of the data used to refine them still dictates their ultimate clinical utility.

Summary updated

Abstract

Recent advancements in pre-trained large foundation models (LFM) have yielded significant breakthroughs across various domains, including natural language processing and computer vision. These models have been particularly impactful in the domain of medical diagnostic tasks. With abundant unlabeled data, an LFM has been developed for fundus images using the Vision Transformer (VIT) and a self-supervised learning framework. This LFM has shown promising performance in fundus disease diagnosis across multiple datasets. On the other hand, deep learning models have long been challenged by dataset quality issues, such as image quality and dataset bias. To investigate the influence of data quality on LFM, we conducted explorations in two fundus diagnosis tasks using datasets of varying quality. Specifically, we explored the following questions: Is LFM more robust to image quality? Is LFM affected by dataset bias? Can fine-tuning techniques alleviate these effects? Our investigation found that LFM exhibits greater resilience to dataset quality issues, including image quality and dataset bias, compared to typical convolutional networks. Furthermore, we discovered that overall fine-tuning is an effective adapter for LFM to mitigate the impact of dataset quality issues.