Investigation of the Initial Quality of Robotic Tile Installation Based on Coupled Eulerian-Lagrangian Approach

Kui Wu, Y. R. Zhang, Xiaoxu Kong, Shuang Zhang2023 · DOI

TL;DR

Researchers have developed a sophisticated numerical model using the Coupled Eulerian-Lagrangian (CEL) approach to optimize how robots install floor tiles. Their findings reveal that applying adhesive horizontally and using a combination of compression and shear vibration during leveling is the "gold standard," eliminating tile rebounding and maximizing the contact area to ensure a defect-free bond.

What Problem Does This Paper Address?

As the construction industry shifts toward automation, tiling robots are becoming more common. However, simply having a robot "do what a human does" isn't enough to guarantee quality. In tiling, "initial quality" depends on how well the adhesive bonds the tile to the concrete—specifically, avoiding air gaps (interfacial defects) and "rebounding" (where the tile slightly lifts after being pressed).

The physics of this process is surprisingly complex. You have a solid tile interacting with a semi-fluid adhesive that undergoes massive deformation. Traditional simulation methods often struggle with this "fluid-structure interaction." This paper seeks to provide a theoretical roadmap for robotic parameters—like how to move the extrusion nozzle and what kind of vibration to apply—to achieve the best possible installation.

Methods

The authors employed the Coupled Eulerian-Lagrangian (CEL) approach. In computational mechanics, "Lagrangian" models are great for solids (like the tile and concrete base) because they track boundaries accurately, but they fail when materials deform excessively. "Eulerian" models handle extreme deformation well (like squishing adhesive) but struggle with clear boundaries. CEL combines both, allowing the adhesive to "flow" as a fluid-like material while interacting with the rigid tile.

Key technical details include:

  • Constitutive Model: The adhesive was modeled using the Drucker-Prager model to simulate its yield stress and plastic flow.
  • Validation: The researchers first performed physical experiments, measuring how a cylinder of adhesive deformed under different weights, and found their numerical model matched the results with less than a 2% margin of error.
  • Simulation Variables: They tested horizontal vs. vertical application patterns, three types of leveling loads (compression, vertical vibration, and shear vibration), varying numbers of adhesive strips (13, 25, 45), and different adhesive yield stresses (200–700 Pa).

Datasets

This study is primarily based on numerical simulation and controlled laboratory experiments rather than large-scale external datasets.

  • Experimental Validation: The authors used a custom dataset of adhesive diameters measured under loads of 2N, 4N, and 6N to calibrate the Drucker-Prager parameters.
  • Simulation Environment: The models utilized millions of Eulerian elements (up to 5.9 million for the leveling model) to ensure high-fidelity results.

Key Insights and Ideas

  • Horizontal Application Wins: When a robot applies adhesive vertically, the strips tend to collapse and bunch up due to gravity and kinetic energy. Horizontal application keeps the strips stable and evenly spaced because the extrusion speed matches the robot's movement, minimizing friction and deformation.
  • Shear Vibration is the Secret Sauce: While vertical vibration (up-and-down) is common, it actually causes uneven adhesive deformation and can reduce the contact area. Shear vibration (side-to-side), however, promotes uniform plastic flow. It effectively "melts" the resistance of the adhesive, allowing the tile to settle perfectly without rebounding.
  • The "Goldilocks" Yield Stress: The adhesive's stiffness (yield stress) matters immensely. If it's too low (<300 Pa), the tile sinks too much; if it's too high, the tile rebounds significantly, creating gaps. A moderate yield stress of around 300 Pa provided the best balance of stability and contact.
  • Diminishing Returns on Strips: Increasing the number of adhesive strips from 13 to 45 only slightly improved the contact area. The way you press the tile is far more important than the number of lines you draw.

Key Results

  • Rebounding Elimination: While vertical vibration reduced tile rebounding by 27.33% compared to simple compression, shear vibration eliminated rebounding entirely.
  • Contact Area Boost: Coupling shear vibration with compression increased the tile-adhesive contact area ($S_1$) by 100% and the adhesive-concrete contact area ($S_2$) by 135.85% compared to standard compression.
  • Defect Reduction: Simulations showed that shear vibration resulted in zero interfacial defects at the adhesive-concrete boundary, whereas compression alone left significant gaps at the tile's edges.

Limitations and Future Work

The authors acknowledge that this study focuses on initial quality—the state of the tile immediately after installation. It does not account for the long-term chemical curing process of the cement or how environmental factors (like temperature and humidity) might change the adhesive's properties over hours or days.

Future research could explore "large-scale tiling systems" where multiple tiles are placed in sequence, as well as the energy efficiency of different robotic vibration modes. Additionally, integrating these findings into real-time robotic control loops using computer vision could be the next step toward fully autonomous, high-quality construction.

Summary updated

Abstract

In this study, the initial quality of robotic tile installation under various construction parameters and material properties of adhesive were investigated based on the fluid&ndash;structure coupling construction models for the first time. First, the models of adhesive application and tile leveling were developed based on the coupled Eulerian&ndash;Lagrangian approach. Then, on the basis of these models, various patterns of adhesive application, types of tile leveling loads, numbers of adhesive strips and yield stresses of adhesive were simulated and their influence laws on the initial quality of robotic tile installation were analyzed. Finally, the influence mechanisms of these parameters on the installation quality were revealed in terms of the spacing between adhesive strips, tile rebounding, contact areas and defect distribution. Results showed that the adhesive with horizontal application possessed smaller plastic deformation, kept stable shape of strips and distributed at equal spacing, compared with the one with vertical application. In contrast to a single compression load, its couplings with vibration loads were beneficial to the reduction of tile rebounding. Among the coupling loads, the coupling of shear vibration with compression considerably increased the tile&ndash;adhesive contact area until no interfacial defect appeared. The increase of the number of adhesive strips exerts few effects on the installation quality, including slight increases of contact areas as well as diminished interfacial defects. In the case of relatively low and high yield stresses of adhesive, the shear vibration effects were respectively large and small which decrease the installation quality.
BibTeX
@misc{wu2023investigation,
  author = {Kui Wu and Y. R. Zhang and Xiaoxu Kong and Shuang Zhang},
  title = {{Investigation of the Initial Quality of Robotic Tile Installation Based on Coupled Eulerian-Lagrangian Approach}},
  year = {2023},
  doi = {10.23967/c.dbmc.2023.086},
}