Inverse Kinematics in Endoscopic Scenarios using MoveIt

Marc Bestmann, Timon Engelke, Rebecca Rodeck, Gerko WendearXiv 2026

TL;DR

Standard inverse kinematics (IK) solvers often fail when robots operate in confined, collision-rich environments like endoscopic surgery or industrial tank inspections. This paper benchmarks existing MoveIt-compatible solvers and demonstrates that kinematic decoupling—splitting the IK problem into distal and proximal parts—can achieve a 100% success rate in under 100ms, a massive leap over baseline performance.

What Problem Does This Paper Address?

Inverse Kinematics is the mathematical process of determining the joint angles needed to place a robot's "hand" (end effector) at a specific target. While this is a solved problem for robots in open spaces, it becomes a nightmare in "endoscopic scenarios."

Imagine a robotic arm trying to thread a needle through a tiny hole into a cluttered tank. Standard solvers like KDL or TracIK are "environment-blind"; they find a mathematically valid pose first and only check for collisions afterward. In tight spaces, the vast majority of mathematically valid poses result in a collision, causing the solver to fail or time out. The authors aim to bridge this gap by evaluating and improving open-source solvers within the popular MoveIt2 framework.

Methods

The researchers explored several strategies to make IK solvers "collision-aware":

  1. Rejection Sampling: The simplest fix. If a solution results in a collision, the solver immediately restarts with a new random seed.
  2. Collision Distance & Penetration Depth: These methods add a "cost" to the optimization process based on how close the robot is to an object. While theoretically sound, the authors found the computational overhead of calculating these distances often outweighed the benefits.
  3. Remote Center of Motion (RCM): A specialized constraint that forces a specific part of the robot (the "shaft") to pass through a fixed point (the "entry hole").
  4. Kinematic Decoupling (KD): The most novel approach tested. Instead of solving for the entire 9+ Degree of Freedom (DoF) chain at once, they split the robot into two:
  5. Distal part: The endoscope inside the tank.
  6. Proximal part: The robotic arm outside. By solving for the distal part first and then "meeting" it with the proximal arm, the search space is drastically reduced.
A family tree of IK solvers categorized by their optimization methods.

Datasets

The authors introduced a new benchmarking tool called EBIKE (based on the REACH software). Unlike standard benchmarks that only test if a pose is reachable in a vacuum, EBIKE evaluates solvers in a specific, collision-heavy environment.

For their tests, they used:

  • Robot: A UR10 industrial arm equipped with the ELISE endoscopic end effector.
  • Scenario: A mock-up of a hydrogen gas tank with a narrow entry port.
  • Target Poses: 1,000 valid random poses distributed inside the tank.
The experimental setup: a UR10 arm inserting the ELISE endoscope into a hydrogen tank.

Key Insights and Ideas

  • Environment Blindness is the Killer: Most MoveIt solvers fail in confined spaces not because the math is hard, but because they don't consider the environment during the search.
  • Simple is Often Better: Surprisingly, adding basic rejection sampling (retrying on collision) allowed solvers like TracIK and BioIK 2 to suddenly outperform the default KDL solver, which previously had an edge simply because it already used this trick.
  • The Power of Decoupling: The "aha moment" was realizing that the complexity of a long kinematic chain is the enemy. By treating the endoscope and the arm as two separate problems (Kinematic Decoupling), the success rate skyrocketed. This mimics how a human might think: "Put the probe where it needs to be, then move the arm to hold it there."

Key Results

The baseline results were stark: in the tank scenario, most standard solvers failed for the majority of poses, even when given a full second to compute.

  • Baseline Failure: Solvers like PickIK and BioIK 2 had near-zero success rates in the tank without modifications.
  • Rejection Sampling Boost: Adding rejection sampling significantly improved TracIK and BioIK 2, but they still struggled to reach high success rates within reasonable time limits.
  • Kinematic Decoupling (KD) Dominance: As shown in Figure 5, the KD approach achieved a ~100% success rate. Compared to the best baseline (KDL), KD was 10x faster and nearly doubled the success rate.
Performance comparison showing the massive success rate jump provided by Kinematic Decoupling (KD).

Limitations and Future Work

While Kinematic Decoupling was the clear winner, the authors noted that their implementation was manual—they had to specify where to split the robot's URDF (Unified Robot Description Format). Future work should focus on automating this split within the MoveIt framework.

Additionally, the Remote Center of Motion (RCM) objective currently only works for robots with straight links. Extending this to more complex, curved, or flexible endoscopic tools would be a valuable next step for medical applications.

Summary updated

Abstract

Inverse kinematics are critical in many robotic applications, yet standard MoveIt-based solvers struggle in confined scenarios. This paper provides a benchmark of the available solvers and compares multiple practical modifications for improving the performance of the solvers. Splitting the IK problem into two parts results in the best performance, leading to a 100% success rate under 100 ms in an endoscopic tank scenario.
BibTeX
@misc{bestmann2026inverse,
  author = {Marc Bestmann and Timon Engelke and Rebecca Rodeck and Gerko Wende},
  title = {{Inverse Kinematics in Endoscopic Scenarios using MoveIt}},
  year = {2026},
  eprint = {2611.20978},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.20978},
}
Figure