Interpretable Orthogonal Latent Diffusion with Scale-Selective Uncertainty for Medical Image Super-Resolution

Onkar Jadhav, Tim FrencharXiv 2026

TL;DR

Diffusion models are fantastic at sharpening blurry MRI scans, right up until they quietly invent plausible-looking tissue boundaries out of thin air. This paper introduces Med-PODiff, a super-resolution framework that swaps black-box neural latents for a mathematically transparent orthogonal basis—enabling it to cleanly separate broad anatomical uncertainty from fine-detail guesswork. Even better, it yields a reference-free "hallucination-risk" map that tells you where the model might be making up fine details, all while running 20× faster than pixel-space diffusion.

What Problem Does This Paper Address?

When reconstructing high-resolution medical images from low-resolution inputs, there is inherent ambiguity: many sharp images could explain the same blurry scan. Diffusion models handle this by generating sharp, realistic samples, and we can estimate their uncertainty by generating an ensemble of reconstructions and seeing where they disagree.

However, standard uncertainty maps give you a single, tangled spatial field. They conflate broad structural ambiguity (e.g., slight overall intensity shifts) with localized fine-detail uncertainty (e.g., crisp, invented tissue boundaries). In clinical settings, those invented fine details—hallucinations—are dangerous because they look completely credible to both radiologists and downstream segmentation algorithms. Existing ways to catch hallucinations usually require ground-truth references or raw scanner measurements at test time. How do we isolate fine-scale hallucination risk directly from the model's own uncertainty?

Methods

Instead of running diffusion on raw pixels or inside a learned Variational Autoencoder (VAE) latent space, Med-PODiff uses a classical math workhorse: Proper Orthogonal Decomposition (POD)—essentially PCA applied to $16 \times 16$ non-overlapping image patches.

  1. Fixed Orthogonal Compression: The authors compute a shared POD basis from training patches, keeping the top $K=128$ modes that capture 99% of the variance. Modes are naturally ordered by energy: early modes represent smooth, low-rank anatomy, while later modes capture crisp edges and fine textures.
  2. ViT Diffusion: A standard Vision Transformer (ViT) denoiser is trained to perform conditional diffusion over these standardized patch coefficients.
  3. Exact Uncertainty Decomposition: Because the POD decoder is fixed and linear, sample variance in coefficient space propagates analytically into pixel space. By splitting the modes at a cutoff ($k_c = 10$), the authors decompose predictive uncertainty into coarse ($U_c$) and fine ($U_f$) maps.
Figure 1: Representative coarse–fine decomposition. Rows show total, coarse, and fine components; columns show the target, predictive mean, absolute component error, and uncertainty. Coarse and fine components use modes 1, . . . , kc and kc+1, . . . , K, respectively, with kc = 10. Signed fine components are shown in absolute value; the coarse-panel grid reflects the non- overlapping 16 × 16 patches.
  1. Hallucination-Risk Score ($H_p$): Newly introduced here, $H_p = U_f \cdot \frac{U_f}{U_c + U_f + \epsilon}$ highlights pixels where fine uncertainty is both large in magnitude and dominant over coarse structural uncertainty—requiring no ground truth at inference.

Datasets

The authors evaluate $4\times$ super-resolution on the multicoil brain subset of fastMRI (19,090 training slices, 1,808 validation, and 2,130 test slices at $256 \times 256$ resolution). Low-resolution inputs are created via $4\times$ bicubic downsampling and tested for robustness using retrospective $4\times$ Cartesian $k$-space undersampling. No new datasets are introduced, though the authors construct controlled synthetic detail-injection tests and use FreeSurfer's SynthSeg to generate reference masks for downstream segmentation tests.

Key Insights and Ideas

  • Variance ordering acts as a proxy for spatial scale: Even though POD orders modes by explained variance rather than spatial frequency (like wavelets or Fourier transforms), a clean double dissociation emerges: coarse uncertainty preferentially predicts coarse errors, and fine uncertainty predicts fine errors—robust across wide mode cutoffs ($k_c \in [2, 80]$).
  • Generic uncertainty $\neq$ hallucination detection: Total uncertainty ($U_{\text{tot}}$) and raw fine uncertainty ($U_f$) cannot tell the difference between errors in measured data vs. unmeasured "null-space" data (gaps near zero). Weighting by dominance ($H_p$), however, selectively flags unsupported null-space hallucinations.
  • Throwing away the 1% tail is safe: Truncating the bottom 1% of POD energy discards very little actual fine-scale error (only 3.8% of the retained fine-error magnitude), meaning the compressed space doesn't blind the uncertainty estimator.

Key Results

Med-PODiff outperforms pixel-space diffusion (PixelDiff), learned-latent diffusion (VAE-LDM), a patch-pixel Diffusion Transformer (DiT), and global POD across accuracy, calibration, and speed:

  • Better & Faster Reconstructions: Achieves 26.72 dB PSNR and 0.9120 SSIM (beating DiT by +0.905 dB PSNR) while generating a sample in 0.091 s—2× faster than DiT (0.186 s) and 20× faster than PixelDiff (1.854 s).
  • Sharp Error & Risk Localization: Total uncertainty detects top-10% high-error pixels at 0.954 AUROC (vs. 0.903 for DiT). On synthetic injected details, reference-free $H_p$ reaches 0.926 AUROC, virtually matching a reference-based comparator (sFRC at 0.928) that peeks at the ground truth.
  • Downstream Segmentation: Improves 3D SynthSeg foreground Dice to 0.775 (vs. 0.759 for DiT and 0.450 for bicubic), and $H_p$ effectively flags where segmentation boundaries will disagree with high-resolution scans ($r = 0.829$).
Visualizing the Hp risk overlay pinpointing fine-scale reconstruction errors along cortical folds.

Limitations and Future Work

  • $H_p$ is a ranking score, not a probability: A score of 0.10 doesn't mean a 10% chance of clinical hallucination; it ranks relative pixel risk.
  • Fixed, locally low-rank basis: The POD basis is frozen after training. Highly unusual pathologies or textures with slower eigenvalue decay might require more modes or adaptive/online basis learning.
  • Synthetic scope: Evaluations rely on fastMRI, synthetic degradations, and automated SynthSeg labels rather than radiologist-annotated clinical hallucinations across diverse scanners.

Summary updated

BibTeX
@misc{jadhav2026interpretable,
  author = {Onkar Jadhav and Tim French},
  title = {{Interpretable Orthogonal Latent Diffusion with Scale-Selective Uncertainty for Medical Image Super-Resolution}},
  year = {2026},
  eprint = {2611.32135},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.32135},
}