Interfacial thermal stresses of segmented thermoelectric generators
Abstract
The segmented structure can effectively improve the performance of a thermoelectric generator (TEG), but the interfacial thermal stress between adjacent segments seriously threatens the reliability of segmented TEGs. Noticing this, we investigate the mechanical performance of a segmented TEG via theoretical and numerical methods. Results show that the structural stress depends on the ratio of cross-sectional areas between p- and n-type TE legs rather than the absolute cross-sectional areas, while the height ratio of different segments has a significant influence on structural stress. Different from structural stress, the thermal stress induced by unmatched thermal expansion between different segments increases rapidly with the increase of cross-sectional area, and can easily exceed 20% of the total interfacial stress. Besides, both the conversion efficiency and interfacial stress can be optimized by adjusting the ratio of cross-sectional areas. Our results provide the theoretical basis and guidance in the design of segmented TEGs.
BibTeX
@article{yan2023interfacial,
author = {Zipeng Yan and Longbing Yi and Haowei Xu and Shaolin Huang and Kun Song and Chunrong Pan and Jun Jiang},
title = {{Interfacial thermal stresses of segmented thermoelectric generators}},
journal = {Journal of Thermal Stresses},
year = {2023},
doi = {10.1080/01495739.2023.2208190},
}Ask Althea to put this paper to the test.