Inter-observer variations of the tumor bed delineation for patients after breast conserving surgery in preoperative magnetic resonance and computed tomography scan fusion

Jie Jiang, Jinhu Chen, Wanhu Li, Yongqing Li, Yiru Chen, Zicheng Zhang, Chengxin Liu, Dan Han, Hongfu Sun, Baosheng Li, Wei HuangResearch 2021 · DOI

TL;DR

This study investigates how different MRI sequences, when fused with CT scans, improve the accuracy and consistency of defining the "tumor bed" (the area where a tumor was removed) in breast cancer patients undergoing radiotherapy. The findings suggest that specific MRI sequences, particularly sdyn-eTHRIVE, significantly reduce variations between different doctors' delineations, leading to more precise treatment planning and potentially smaller radiation volumes.

What Problem Does This Paper Address?

Accurately defining the tumor bed (TB) after breast-conserving surgery (BCS) is crucial for effective radiotherapy. The TB is the target volume that needs to be irradiated to eliminate any remaining cancer cells and reduce the risk of local recurrence. However, delineating this area can be challenging due to factors like the presence of seroma (fluid collection), clips used during surgery, and the inherent variability in how different clinicians interpret medical images. Traditional methods using only computed tomography (CT) scans have shown limitations in precisely defining the TB, leading to inconsistencies in treatment planning. This paper aims to address this by exploring how preoperative magnetic resonance imaging (pre-MRI), fused with postoperative CT (post-CT), can improve the accuracy and reduce inter-observer variability in TB delineation compared to using post-CT alone.

Methods

The researchers analyzed pre-MRI and post-CT scans from 10 breast cancer patients who had undergone BCS and were scheduled for radiotherapy. The pre-MRI scans were acquired using six different sequences: T1, T2, T2W-SPAIR, DWI, dyn-eTHRIVE, and sdyn-eTHRIVE. These pre-MRI scans were then fused with the post-CT scans, which were taken in the same prone position.

Five expert observers (three radiation oncologists and two radiologists) were tasked with delineating the clinical target volume (CTV) and planning target volume (PTV). For CT-based delineation, they used post-CT scans. For MRI-based delineation, they used the fused pre-MRI and post-CT images. The gross tumor volume (GTV) from pre-MRI was expanded by 10mm to form the CTV-pre-MRI, and then further expanded by 15mm to create the PTV-pre-MRI, with specific restrictions to avoid skin and chest wall interfaces.

The study evaluated inter-observer variability using three metrics: mean volume, conformity index (CI), and Dice coefficient (DC). These metrics help quantify how consistently the observers agreed on the size and shape of the delineated volumes.

Datasets

The study utilized imaging data from 10 patients who underwent lumpectomy and lymph node dissection for invasive ductal carcinoma. These patients were scheduled for adjuvant radiotherapy. The data included preoperative MRI scans (acquired using six different sequences) and postoperative CT scans. No new benchmark datasets were introduced; the study used existing patient data for its analysis.

Key Insights and Ideas

  • MRI Fusion is Key: Combining pre-MRI with post-CT significantly improves the definition of the tumor bed compared to CT alone.
  • Reduced Variability is Crucial: The primary benefit of MRI fusion lies in reducing the differences in how multiple doctors delineate the target volume. This consistency is vital for accurate and reproducible treatment.
  • Specific MRI Sequences Shine: Not all MRI sequences are created equal for this task. The sdyn-eTHRIVE sequence, in particular, demonstrated superior performance in terms of observer agreement.
  • Smaller Treatment Volumes: By providing a more precise definition of the tumor bed, MRI fusion can lead to smaller target volumes, potentially reducing radiation exposure to healthy tissues and minimizing side effects.

Key Results

  • Smaller Volumes with MRI: Mean volumes for both CTV and PTV were consistently smaller when delineated using pre-MRI fused with post-CT compared to CT-based delineation alone.
  • Improved Observer Consistency: The Dice coefficient (DC) and Conformity Index (CI) were generally higher for MRI-based delineations across all sequences, indicating better agreement among observers.
  • sdyn-eTHRIVE Stands Out: The sdyn-eTHRIVE sequence showed the lowest inter-observer variability, with the highest DC values for both CTV and PTV. For PTV, the DC was 0.93 with sdyn-eTHRIVE, compared to 0.79 for CT.
  • Significant Volume Reduction: Target volume reduction percentages were notable, with PTV volumes reduced by up to 30% when using pre-MRI sequences compared to CT.

Limitations and Future Work

The authors acknowledge several limitations:

  • Small Sample Size: The study included only 10 patients, which limits the generalizability of the findings.
  • Unclear True Tumor Volume: The exact true tumor volume and its extended margin were not precisely defined by pathological confirmation, making it difficult to definitively assess MRI's over- or underestimation.
  • Registration Challenges: Rigid registration between pre-MRI and post-CT datasets can be affected by the non-rigid nature of breast shape changes over time, potentially leading to inconsistencies. Deformable image registration (DIR) is suggested as a potential future tool, though its reliability for multimodality imaging is noted as a challenge.
  • Variability in Clinical Factors: Factors like infection after surgery or individual differences in how clinicians interpret images (even with guidelines) can still contribute to variability.

Future work could focus on larger, multi-center studies to validate these findings. Further research into optimizing registration techniques and developing standardized protocols for MRI-based TB delineation would also be beneficial. The study suggests that sdyn-eTHRIVE is a promising sequence for improving the accuracy and consistency of TB delineation in breast cancer radiotherapy.

Summary updated

Abstract

Abstract Purpose: Tumor bed (TB) delineation based on preoperative magnetic resonance imaging (pre-MRI) fused with postoperative computed tomography (post-CT) were compared to post-CT only to define pre-MRI may aid in improving the accuracy of delineation. Methods and materials: The pre-MRI imaging of 10 patients underwent radiotherapy (RT) after breast conserving surgery (BCS) were reviewed. Post-CT scans were acquired in the same prone position as pre-MRI. Pre-MRI and post-CT automatically match and then manual alignment was given to enhance fusion consistency. 3 radiation oncologists and 2 radiologists delineated the clinical target volume (CTV) for CT-based. The gross target volume (GTV) of pre-MRI-based was determined by the volume of tumor acquired with 6 sequences: T1, T2, T2W-SPAIR, DWI, dyn-eTHRIVE and sdyn-eTHRIVE, expended 10 mm to form the CTV-pre-MRI. Planning target volume (PTV) for each sequence was determined by CTV extended 15 mm, trimmed to 3mm from skin and the breast-chest wall interface. The variability of the TB delineation were developed as follows: the mean volume, conformity index (CI) and dice coefficient (DC). Results: The mean volumes of CTV and PTV delineated with CT were all larger than those with pre-MRI. The lower inter-observer variability was observed from PTV, especially in sdyn-eTHRIVE in all sequences. For each sequence of pre-MRI, all DCs were larger than post-CT, and the largest DC was observed by sdyn-eTHRIVE sequence fusion to post-CT. The overlap for PTV was significantly improved in the pre-MRI-based compared with the CT-based. Conclusions: TB volumes based on pre-MRI were smaller than post-CT with CVS increased. Pre-MRI provided a more precise definition of the TB with observers performed a smaller inter-observer variability than CT. Pre-MRI, especially in sdyn-eTHRIVE sequence, should help in reducing treatment volumes with the improved accuracy of TB delineation of adjuvant RT of breast cancer. Keywords: Breast cancer, radiotherapy, tumor bed, magnetic resonance imaging, computed tomography
BibTeX
@inproceedings{jiang2021inter,
  author = {Jie Jiang and Jinhu Chen and Wanhu Li and Yongqing Li and Yiru Chen and Zicheng Zhang and Chengxin Liu and Dan Han and Hongfu Sun and Baosheng Li and Wei Huang},
  title = {{Inter-observer variations of the tumor bed delineation for patients after breast conserving surgery in preoperative magnetic resonance and computed tomography scan fusion}},
  booktitle = {Research},
  year = {2021},
  doi = {10.21203/rs.3.rs-367843/v1},
}
Figure