Integration and calibration of NDIR CO 2 low-cost sensors, and their operation in a sensor network covering Switzerland

Michael Mueller, Peter Graf, Jonas Meyer, Anastasia Pentina, Dominik Brunner, Fernando Pérez‐Cruz, Christoph Hueglin, Lukas Emmenegger2019

TL;DR

This paper details the integration and calibration of over 300 low-cost NDIR CO2 sensors into a Swiss-wide network. Despite limitations with high humidity and detecting small gradients, the carefully calibrated and processed sensors achieve an accuracy of 8-12 ppm, enabling the resolution of site-specific CO2 signals.

What Problem Does This Paper Address?

Accurate and widespread monitoring of atmospheric CO2 is crucial for understanding climate change and carbon cycles. While high-end instruments exist, their cost and complexity limit dense spatial coverage. Low-cost sensors offer a potential solution, but their accuracy, reliability, and long-term stability in real-world conditions are significant challenges. This paper addresses the problem of how to effectively deploy, calibrate, and process data from a large network of low-cost NDIR CO2 sensors (SenseAir LP8) to achieve meaningful scientific data for atmospheric CO2 monitoring.

Methods

The authors developed a comprehensive approach for deploying and processing data from the LP8 sensors. Key methods include:

  • Extended Sensor Model: A Beer-Lambert law-based model was extended with empirical parameters to account for temperature, pressure, and optical/thermal effects. This model (Eq. 4) was compared to a simplified version (Eq. 5) for robustness.
  • Multi-stage Calibration: Sensors underwent initial calibration in controlled climate and pressure chambers, followed by co-location with a high-precision reference instrument (Picarro) under ambient conditions.
  • Data Processing Pipeline: This involved:
  • Outlier Detection: Two methods were employed: one based on a sensor-specific relative humidity threshold (RHtrsh) and another more adaptive algorithm that learns sensor behavior in the field without reference data.
  • Drift Correction: A two-step algorithm was developed to identify periods of slow and fast sensor behavior and correct for drift, primarily using high wind speed events and co-located reference measurements.
  • Humidity Flagging: A method to flag measurements affected by high relative humidity (>85%) was crucial due to its significant impact on LP8 sensor performance.
  • Low Power Network (LPN): LoRaWAN technology was utilized for reliable, energy-efficient data transmission from the sensor nodes.

Datasets

  • Calibration Data: Measurements from climate and pressure chambers, and ambient co-location data with Picarro instruments at the DUE site.
  • Deployment Data: Data from over 300 LP8 sensors deployed across Switzerland in the Carbosense network over 19-25 months.
  • Reference Data: CO2 measurements from high-precision Picarro instruments at various sites (DUE, PAY, GIMM, etc.) and HPP sensors were used for calibration, drift correction, and validation. Meteorological data from MeteoSwiss was also used.

Key Insights and Ideas

  • Humidity is a Major Hurdle: High relative humidity (>85%) significantly impairs LP8 sensor measurements, necessitating robust filtering that can lead to data loss. This is a critical limitation for deployment in humid environments.
  • Careful Calibration is Paramount: The accuracy achieved (8-12 ppm) is highly dependent on meticulous initial calibration and continuous monitoring.
  • Drift is Inevitable and Addressable: LP8 sensors exhibit drift over time, but this can be effectively corrected using a combination of meteorological data (wind speed) and co-located reference measurements, especially during specific atmospheric conditions.
  • Adaptive Outlier Detection is Powerful: An outlier detection algorithm that learns sensor behavior in the field, without relying on reference instruments, proves to be a valuable and robust tool, especially in challenging humidity conditions.
  • Low-Cost Sensors Can Resolve Significant CO2 Variations: While not suitable for detecting small regional gradients, these sensors, with proper processing, can resolve CO2 changes of 20 ppm or more, which is sufficient for many site-specific applications.

Key Results

  • Accuracy: Calibrated and processed LP8 sensors achieved an accuracy of 8-12 ppm over 19-25 months of deployment.
  • Data Loss: High relative humidity (>85%) leads to significant data loss due to filtering.
  • Resolution: Sensors can resolve CO2 changes/differences larger than approximately 20 ppm.
  • Network Scale: Over 300 LP8 sensors were integrated and operated within the Carbosense network.
  • Data Transmission: LoRaWAN proved to be a reliable and energy-efficient solution for data transmission.
  • Drift Correction Effectiveness: The drift correction method, particularly during windy periods, showed good results for sites on the Swiss plateau.

Limitations and Future Work

  • Humidity Sensitivity: The inherent sensitivity of LP8 sensors to high humidity remains a significant limitation, impacting data yield.
  • Small Gradients/Trends: The sensors are not suitable for detecting very small regional CO2 gradients or long-term trends.
  • Drift Correction Dependence: The drift correction method relies on specific meteorological conditions (high wind), which can limit its applicability. Future work could involve using atmospheric transport models to improve the identification of suitable correction periods and to better account for vertical CO2 gradients.
  • Sensor-to-Sensor Variability: While the processing pipeline is robust, individual sensor behavior can vary, requiring sensor-specific calibration and monitoring.
  • Future Improvements: The authors suggest further improvements to the processing scheme and the potential for using atmospheric transport models to enhance drift correction. The development of more advanced data-driven models is also an ongoing area of research.

Summary updated

Abstract

More than 300 LP8 CO2 sensors were integrated into sensor units and evaluated for the purpose of long-term operation in the Carbosense CO2 sensor network in Switzerland. Prior to deployment, all sensors were calibrated in a pressure and climate chamber, and in ambient conditions co-located with a reference instrument. To investigate their long-term performance and to test different data processing strategies, 18 sensors were deployed at five locations equipped with a reference instrument after calibration. Their accuracy during 19 to 25 months deployment was between 8 to 12 ppm. This level of accuracy requires careful sensor calibration prior to deployment, continuous monitoring of the sensors, efficient data filtering, and a procedure to correct drifts and jumps in the sensor signal during operation. High relative humidity (> ∼85 %) impairs the LP8 measurements, and corresponding data filtering results in a significant loss during humid conditions. The LP8 sensors are not suitable for the detection of small regional gradients and long-term trends. However, with careful data processing, the sensors are able to resolve CO2 changes and differences with a magnitude larger than about 20 ppm. Thereby, the sensor can resolve the site-specific CO2 signal at most locations in Switzerland. A low power network (LPN) using LoRaWAN allowed reliable data transmission with low energy consumption, and proved to be a key element of the Carbosense low-cost sensor network.
BibTeX
@misc{mueller2019integration,
  author = {Michael Mueller and Peter Graf and Jonas Meyer and Anastasia Pentina and Dominik Brunner and Fernando Pérez‐Cruz and Christoph Hueglin and Lukas Emmenegger},
  title = {{Integration and calibration of NDIR CO <sub>2</sub> low-cost sensors, and their operation in a sensor network covering Switzerland}},
  year = {2019},
  doi = {10.5194/amt-2019-408},
}

Loading related content...

Figure