TL;DR
This paper introduces a novel control strategy, Integral Plus Resonant Sliding Mode Direct Power Control (IRSMC DPC), for Voltage Source Converter High Voltage Direct Current (VSC-HVDC) systems operating under unbalanced grid voltage conditions. The proposed method offers flexible power control by allowing continuous adjustment of active and reactive power ripple amplitudes, ensuring stable system performance and non-distorted AC currents even during grid disturbances.
What Problem Does This Paper Address?
VSC-HVDC technology is crucial for modern power grids, offering flexible power transmission and integration of renewable energy sources. However, these systems are vulnerable to grid voltage unbalance, which can degrade control performance and even lead to instability. Existing control strategies, like Vector Control (VC) and standard Direct Power Control (DPC), often struggle with unbalanced conditions, requiring complex sequence component extraction or exhibiting performance degradation. Specifically, controlling both active and reactive power simultaneously while maintaining non-distorted AC currents under these conditions, and allowing for flexible ripple control, remains a challenge.
Methods
The core of the proposed solution is the Integral Plus Resonant Sliding Mode Direct Power Control (IRSMC DPC) strategy. It builds upon Direct Power Control (DPC) by incorporating:
- Generalized Power Compensation: Through detailed instantaneous power flow analysis, the authors derive a method to control the ratio of active and reactive power ripples. This allows for flexible power control, enabling the system to achieve desired performance on both AC and DC sides.
- Integral and Resonant Control Laws: To address the challenges of unbalanced grids and time delays, a sliding mode controller is designed. This controller integrates proportional, integral, and resonant control laws. The integral component helps eliminate steady-state errors, while the resonant component specifically targets the twice-grid-frequency oscillations inherent in unbalanced conditions, aiming for non-distorted AC currents.
- Sliding Mode Control (SMC): This robust control technique is employed to ensure system stability and performance despite parameter uncertainties and disturbances.
Datasets
Not discussed in the paper. The study relies on simulations using MATLAB/SIMULINK.
Key Insights and Ideas
- Flexible Ripple Control is Key: The paper highlights that under unbalanced grid voltage, active and reactive power terms naturally develop ripples at twice the grid frequency. Instead of eliminating these entirely, the IRSMC DPC strategy leverages this by allowing for continuous control over their amplitudes. This flexibility is crucial for achieving desired system performance and non-distorted AC currents.
- Integral and Resonant Components are Synergistic: Combining integral control for steady-state accuracy with resonant control for specific frequency components (twice the grid frequency) proves effective in handling the complexities of unbalanced grids.
- SMC for Robustness: The use of sliding mode control provides inherent robustness against parameter variations and external disturbances, which are common in real-world power systems.
- Generalized Power Compensation: The derived generalized power compensation method is a significant contribution, offering a systematic way to manage active and reactive power ripple amplitudes, moving beyond fixed objectives.
Key Results
The paper demonstrates the effectiveness of the IRSMC DPC strategy through simulation studies on a two-terminal VSC-HVDC system. Key findings include:
- Satisfactory Performance under Unbalance: The IRSMC DPC strategy successfully achieves the control objectives for both converter stations (CS1 and CS2) even during sudden grid voltage unbalance.
- Elimination of Power Ripples (Specific Cases): The strategy can be configured to eliminate active power ripples at the PCC of CS1 and reactive power ripples at the PCC of CS2, as shown in Figure 5.
- Accurate Power Tracking: The proposed controller enables accurate tracking of active and reactive power references.
- Non-Distorted AC Currents: The strategy ensures that AC currents remain sinusoidal, even when the grid voltage is unbalanced.
- Robustness Demonstrated: Simulations show that the IRSMC DPC strategy maintains satisfactory performance in the presence of parameter inaccuracies (e.g., inductance variations) and frequency deviations.
Limitations and Future Work
- Simulation-Based: The study is based on simulations using MATLAB/SIMULINK. While the results are promising, experimental validation is necessary to confirm the strategy's effectiveness in real-world applications.
- Practical Factors: The authors acknowledge that practical factors like switching device imperfections and time delays were considered, but further investigation into their impact and mitigation might be beneficial.
- Future Work: The authors explicitly state that experimental verification and implementation in real-world systems are planned for future work.
Summary updated