Innovative techniques for automatic multi-CD-SEM image quality monitoring and matching
Abstract
As semiconductor devices continue to shrink, precision and stability for the CD-SEM has become increasingly important. Given today's critical dimension (CD) measurements for DUV and sub-DUV process control and development. In particular: maintenance and monitoring of tight tolerances for, tool-to-tool, and across-fab CD-SEM matching have quickly become mandatory for chip manufacturing and development. KLA-Tencor continues to improve its measurement precision and tool automation capabilities for its 8XXX CD-SEM. For 0.25um processes and larger, current tool monitoring procedures are sufficient; however, for processes smaller than 0.25um, the demand for better system monitoring has become increasingly critical especially in multiple CD-SEM matching. In this paper, we incorporated the KLA-Tencor 8XXX CD-SEM Pattern Qualification Confirmation (PQC) for automated monitoring of CD-SEM image quality. Furthermore, we characterized patterned and etched wafers on a Polysilicon substrate. The characterization of electron-beam induced CD growth on various size line widths and pitches will be reported. From the results, we will determine the optimal substrate and pitch size for long-term CD monitoring of CD-SEM.
BibTeX
@inproceedings{zhou2001innovative,
author = {Hai-Qing Zhou and Chih-Yu Wang and Joseph P. Pratt},
title = {{Innovative techniques for automatic multi-CD-SEM image quality monitoring and matching}},
booktitle = {Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE},
year = {2001},