NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Infrared thermography in clinical practice: a literature review

Qian Liu, Mingzhu Li, Wenping Wang, Shengbo Jin, Haozhe Piao, Yuxin Jiang, Ningxin Li, Huini YaoEuropean 2025

Abstract

The extensive utilisation of infrared thermography in clinical settings signifies the technology's considerable potential. Addressing its current limitations can optimise its benefits.

Introduction

Medical infrared thermography (IRT) is emerging as a versatile, non-invasive, and radiation-free imaging modality. Unlike traditional imaging techniques—such as X-rays, CT scans, and MRIs—which are primarily designed to detect anatomical or structural damage, IRT maps body surface temperatures to identify physiological abnormalities. Because many diseases alter local metabolism and blood flow long before structural changes become visible, IRT serves as a critical early-warning system by capturing thermal gradients emitted by the body in the 8–14 μm wavelength range.

Technical Advancements and Methodology

This literature review synthesizes findings from 51 relevant articles to map the current landscape of IRT. A key theme in recent research is the move away from subjective manual interpretation toward automated, high-precision methodologies:

  • Dynamic Thermography (DTI): This technique improves sensitivity by identifying pixels with consistent initial temperatures, helping to overcome the limitations of external cooling devices.
  • Machine Learning Integration: The application of algorithms like Entropy Gradient Support Vector Machines (EGSVM) and Convolutional Neural Networks (e.g., ResNet-50) has drastically improved clinical viability by automating the classification of thermal patterns.
  • Surgical Overlay: IRT is being used in real-time during procedures, such as lung segmental resections, to visually define boundaries between healthy and ligated tissues based on immediate temperature drops.

Clinical Applications and Results

IRT has demonstrated impressive quantitative results across multiple medical domains, particularly in oncology, dermatology, and specialized diagnostics.

Summary of clinical studies in oncology and dermatology

Oncology and Dermatology

As detailed in the table above, IRT has shown high diagnostic compliance in large-scale studies. In breast cancer screening, a cohort of 11,200 patients helped validate an 89.3% diagnostic compliance rate. For oral cancer, EGSVM-driven IRT achieved 84.8% sensitivity in detecting cervical lymph node metastases, performing non-inferiorly to enhanced CT scans. In dermatology, dynamic thermography distinguished benign from malignant skin lesions with 95% sensitivity and 83% specificity.

Specialized Diagnostics and Critical Care

IRT's utility extends into critical care and postoperative monitoring, where it provides objective data on inflammation and perfusion.

Clinical studies on septic shock and postoperative inflammation

Beyond the results in Figure 6, IRT is showing promise in neurodevelopmental diagnostics. Researchers have achieved a 96% classification accuracy in distinguishing subjects with Autism Spectrum Disorder (ASD) by measuring facial skin temperature changes in response to emotional stimuli. Additionally, IRT has been used to predict burn depth with 87.2% accuracy, nearly doubling the accuracy of standard clinical visual assessments (54.1%).

Limitations and Future Outlook

Despite its significant potential, the authors note that the FDA does not yet recognize IRT as a stand-alone diagnostic tool. Several hurdles remain:

  1. Lack of Harmonization: There are currently no standardized technical parameters or environmental controls (e.g., room temperature and humidity) for testing protocols.
  2. Confounding Variables: Factors such as a patient's circadian rhythm, exercise level, or simple sweating can alter thermograms, potentially leading to false positives.
  3. Low Specificity: Because many different conditions cause localized heat, IRT often requires complementary imaging for a definitive differential diagnosis.

Conclusion

The core value of IRT lies in the principle that physiology precedes anatomy. By detecting hyper-metabolic states or inflammatory responses before physical tissue degradation occurs, IRT offers a unique diagnostic window. Future advancements in high-resolution hardware and sophisticated image processing algorithms will be essential to establishing disease-specific thermal signatures and transitioning IRT into mainstream clinical practice.