Abstract
Non-stationary surface EMG signals recorded during dynamic contractions can be accurately classified for the control of multi-function prostheses.
Introduction
State-of-the-art myoelectric prostheses, which utilize surface electromyography (sEMG) to interpret user intent, frequently demonstrate high performance in controlled laboratory settings but fail to maintain reliability in daily use. A primary cause for this discrepancy is the nature of the training data. Most systems are trained on static, isometric contractions where the user holds a steady gesture. However, real-world limb movement is inherently dynamic, producing non-stationary signals that differ significantly from static holds. This study investigates how the inclusion of dynamic transition data in training sets affects the classification accuracy of multi-function prostheses.
Methodology
The researchers conducted a 9-class movement experiment involving eight able-bodied subjects. The movement classes included wrist flexion/extension, forearm rotation, and various functional hand grips. sEMG signals were recorded using six electrode pairs placed around the forearm.
Each trial consisted of a 10-second contraction cycle: a 3-second "reach" (ramp-up) to the target force, a 4-second static hold, and a 3-second return to rest (ramp-down). To evaluate the impact of data composition, the researchers tested five distinct training windows, ranging from a purely static 4-second hold to the full 10-second dynamic cycle.
Two feature sets were evaluated: Time Domain features combined with Autoregressive coefficients (TD+AR) and Wavelet Transform (WT) features. These were processed using three classification architectures: Linear Discriminant Analysis (LDA), Support Vector Machine One-Versus-One (SVM-OVO), and Support Vector Machine One-Versus-Rest (SVM-OVR).
Key Results and Discussion
The study revealed that training exclusively on static data leads to significant error spikes during the onset and offset of movements. Implementing a simple onset detector—specifically the Teager-Kaiser energy operator—allowed the system to ignore ambiguous low-energy signals at the start of contractions, which substantially reduced the baseline error rate.
As the training set expanded to include more dynamic data, classification performance generally improved. For the LDA classifier, transitioning from a 4-second static training set to a threshold-based dynamic set reduced the error rate from 11.9% to 7.8%. The combination of Wavelet features and SVM-OVO achieved the highest overall accuracy with an error rate of 6.3%.
Interestingly, the SVM-OVR classifier performed poorly when dynamic data was added. This was attributed to class imbalance; the "rest" class became disproportionately large during dynamic training, causing the classifier to favor the rest state over specific motion classes.
Conclusion
The findings suggest that the robustness of myoelectric control is heavily dependent on the inclusion of dynamic transitions in the training phase. While complex features like Wavelets provide the best accuracy, simpler TD+AR features paired with LDA offer a computationally efficient alternative that is nearly as effective. Future work should focus on validating these results with amputee subjects and exploring direct transitions between different active gestures.
Summary updated