Influence of priming time and primer’s concentrations on bovine enamel bond strengths
Lists
Only you see this
Abstract
This study investigated the effects of priming time (5, 30 or 60 s), 10-MDP (10-methacryloyloxydecyl dihydrogen phosphate)-containing primer’s concentrations (0.5, 1, 5, 10 and 20% (w/w)) and two neutral primers (5% (w/w) of 10-MDP-Na or EDTA-2Na) on bovine enamel microtensile bond strength (μTBS) using a novel prime-and-rinse approach. After priming, the enamel surfaces were thoroughly water-sprayed and dried before resin composite was placed. There was a significant influence of primer’s concentrations and priming time on bovine enamel μTBS when 10-MDP-containing primers were used (p < 0.001), revealing the optimal priming time (30 s) and the best combination (priming with 20% of 10-MDP for 30 s). The prime-and-rinse approach might be an innovative supplement to contemporary dental adhesive procedures. The neutral primer (5% of 10-MDP-Na) produced moderate enamel μTBS on highly polished enamel surfaces, while another neutral primer (5% of EDTA-2Na) failed, suggesting that chemical bonding of 10-MDP to enamel hydroxyapatite crystallites could yield detectable bond strengths on smooth enamel surfaces.
BibTeX
@article{wang2013influence,
author = {Xiaomiao Wang and Chaoyang Wang and Ling Zhang and Zhenliang Zhang and Baiping Fu and Matthias Hannig},
title = {{Influence of priming time and primer’s concentrations on bovine enamel bond strengths}},
journal = {Journal of Adhesion Science and Technology},
year = {2013},
doi = {10.1080/01694243.2013.792027},
}Loading related content...