Influence of oxygen-enriched aeration with membrane and wide-diameter on performances of recirculated membrane bioreactor(RMBR)
Abstract
RMBR of the oxygen-enriched aeration with membranes enhanced the wastewater treatment load.The resulted effluent had low turbidity and no detectable SS.The removals of COD and ammonia nitrogen were up to 95% and 98% respectively,which meets the quality standard for the reuse of civil wastewater.Experimental results demonstrate that the system was stable in a scheduled time without plug-up by using 2 mm diameter PES hollow fiber membranes.Increasing trans-membrane pressure(TMP) resulted in an increase in flux,and the flux was independent of TMP above a critical value.Increasing flow velocity reduced the formation of the fouling layer,which was independent of flow velocity once it reached a critical value.For every MLSS,there was a suitable TMP and flow velocity.At the MLSS of 2.2,3.1,and 4.6 g/L,the suitable TMPs were 100,80,and 60 kPa respectively,and the suitable velocity was between 0.6 and 0.9 m/s.The optimal back-flush period was 40 min,and the optimal back-flush procedure was to backflush for 60 s then forward-flush for 15 s with the influent valve open.The flux was restored to about 78% and 89% of its original flux when back-flush and chemical cleaning were applied.The system exhibited excellent stability during a 300 hours running.
BibTeX
@inproceedings{zhou2008influence,
author = {Xiaoling Zhou},
title = {{Influence of oxygen-enriched aeration with membrane and wide-diameter on performances of recirculated membrane bioreactor(RMBR)}},
booktitle = {Membrane},
year = {2008},
}Ask Althea to put this paper to the test.