Abstract
In view of that part of motor fault state was difficult to be simulated by experiment; fault characteristic value was hard to be obtained quantitatively and so on. This paper established the finite element models of asynchronous motor in different fault conditions by Ansoft, extracted and analyzed stator current under different degree of motor broken bars, stator winding inter-turn short circuit and the air gap eccentric fault, obtained the fault characteristics with the evolution of fault degree. Finally established asynchronous motor fault experimental platform, through the comparison of the experimental data and the fault feature of the finite element models, validated the rationality of fault feature extraction method based on Ansoft.
Introduction
Induction motors are essential components in industrial applications, yet diagnosing internal health remains a significant challenge. Traditional diagnostic methods typically rely on two main pillars: empirical data analysis and mathematical modeling. Data analysis involves monitoring physical signals like vibration or current, which can be difficult to quantify for specific faults such as air gap eccentricity. Conversely, mathematical modeling using equivalent circuits becomes exceedingly complex and often inaccurately represents a motor once it loses its electromagnetic symmetry due to damage.
This research addresses the difficulty of obtaining quantitative, reliable fault data without the need for destructive testing on expensive physical hardware. By leveraging Finite Element Analysis (FEA), the authors provide a method to simulate various failure scenarios and extract precise "fingerprint" features for diagnostic purposes.
Methodology and Fault Simulation
The study utilizes a hybrid approach that combines high-fidelity simulation with physical validation. The core of the simulation work was performed using Ansoft software to build a 2D FEA model of a 7.5kW asynchronous motor. FEA is particularly effective here as it calculates complex magnetic fields by discretizing the motor structure into small elements, allowing for precise modeling of asymmetries.
The researchers systematically introduced faults into the digital model to observe their effects:
- Broken Rotor Bars: Modeled by removing bars in various positions and quantities to simulate different degrees of severity and asymmetry.
- Stator Winding Short Circuits: Simulated by reducing the number of active winding turns.
- Air Gap Eccentricity: Modeled by shifting the rotor axis to create static and dynamic eccentricities.
Harmonic Fingerprints and Key Insights
A critical finding of the study is that fault characteristics are significantly more pronounced under full load conditions compared to light loads. This suggests that early-stage faults might be overlooked if diagnostics are only performed during idle or low-load periods.
Furthermore, the research highlights that for broken rotor bars, the spatial distribution (position) of the breaks is as critical as the total number of broken bars. Increased asymmetry in the rotor leads to more distinct harmonic signatures in the stator current. Each fault type was found to leave a unique "fingerprint" on the current spectrum:
- Broken Bars: Induce sideband frequencies at $(1 \pm 2ks)f$.
- Short Circuits: Primarily amplify the 3rd, 5th, and 7th harmonics.
- Eccentricity: Characterized by the appearance of 25Hz and 75Hz components.
Results and Experimental Validation
The simulation results provided quantitative data on fault progression. For instance, as a stator short circuit deepened, the 3rd harmonic content rose from -5 dB (with 15 turns shorted) to +16.5 dB (with 70 turns shorted). Eccentricity detection was similarly successful, with dynamic eccentricity producing a noisier spectrum with a wider range of even and odd harmonics.
To validate these FEA findings, a physical testbed using a YM132-4 motor was constructed. Faults were manually introduced—such as physical breaking of rotor bars and using external rheostats to simulate winding shorts. The experimental data showed a high degree of consistency with the FEA models, confirming that software simulation is a reliable and cost-effective proxy for physical fault testing.
Conclusion
This study demonstrates that FEA-based simulation using Ansoft is a powerful tool for extracting induction motor fault features. While computationally more intensive than simple mathematical models, its accuracy in capturing the effects of electromagnetic asymmetry is superior. These findings provide a robust basis for identifying fault types and degrees, paving the way for the development of automated, AI-driven diagnostic systems that can monitor motor health in real-time using these identified harmonic signatures.