Indirect measurement of the infrared pen point used in a short throw interactive projection system

Qian Zhou, Kai Ni, Yuping Lu, Liangjun Chen, Yuan Gao, Liang He, Hongfeng Guo, Jianshe Ma, Yi Li, Minxia LiuProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 2010

Abstract

Short throw interactive projection systems are widely used in education, training, commerce, and entertainment in recent years. Different interactive techniques have been developed. And among them, the infrared location technique is one of the attracting methods, because of the advantages such as independent of whiteboard and low cost, and so on. However, the main defect is that the infrared pen point is easy to be blocked by user's hand. In this paper, we introduced our recent progress on indirect measurement of the pen point used in a short throw interactive projection system. Two infrared LEDs are fixed along the pen's body near the tail end. By separately measuring the position of the two LEDs, the location of the front end pen point can be calculated. Such placement can effectively avoid the LEDs from being blocked by user's hand. The mathematical model of this measurement scheme is given separately in the situations of infinite focal length and short focal length of the camera. Errors are analyzed by both analytical and numerical method. We used our position sensitive detector (PSD) based location system to test the effect of this method.
BibTeX
@inproceedings{zhou2010indirect,
  author = {Qian Zhou and Kai Ni and Yuping Lu and Liangjun Chen and Yuan Gao and Liang He and Hongfeng Guo and Jianshe Ma and Yi Li and Minxia Liu},
  title = {{Indirect measurement of the infrared pen point used in a short throw interactive projection system}},
  booktitle = {Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE},
  year = {2010},
  doi = {10.1117/12.870709},
}