In-Situ Sulfur Isotopic Analysis Of Sulfate By Laser Ablation Multiple Collector Inductively Coupled Plasma Mass Spectrometry (LA-MC-ICP-MS)

Jue Lu, Wei ChenAtomic 2020 · DOI

Abstract

Sulfate minerals are widely distributed in nature, and their sulfur isotopic signatures offer a largely untapped source of potential information for improving our understanding of magmatic, hydrothermal, and sedimentary processes. In this study, we describe an analytical procedure for measuring the sulfur isotopic compositions of natural sulfate-bearing samples using a LA-MC-ICP-MS technique. YF-2 barite ($BaSO_4$) from the Yongfu hydrothermal deposit was adopted as the reference material for sulfur isotopic determination. The sulfur isotopic ratios for NBS 127 and IAEA-SO-5 barium sulfate are validated using YF-2 pressed powder tablets as the internal reference standard, yielding results that overlap with recommended values. The analytical results suggest minimal sulfur isotopic fractionation between barite and other S-bearing matrices using both the RESOlution and GeoLasHD laser systems.

Introduction: The Need for In-Situ Resolution

Sulfur isotopes ($\delta^{34}S$) serve as critical geochemical "fingerprints" for understanding magmatic, hydrothermal, and sedimentary processes. Traditionally, these are measured using bulk techniques like Elemental Analyzer-Isotope Ratio Mass Spectrometry (EA-IRMS). While precise, bulk methods destroy spatial context, masking isotopic zonation or variations within a single crystal that could reveal changes in fluid chemistry or redox conditions over time.

In-situ techniques like LA-MC-ICP-MS offer the necessary spatial resolution but face two major hurdles: instrumental mass bias and matrix effects. Matrix effects occur when the physical or chemical structure of a mineral influences how the laser ablates the material, leading to inaccurate isotopic ratios. Furthermore, there has been a historical lack of well-characterized, widely available natural sulfate standards for calibrating these instruments.

Methods and Analytical Protocol

The authors utilized a Nu Plasma II MC-ICP-MS coupled with two different 193 nm ArF excimer laser systems: RESOlution and GeoLasHD.

Analytical workflow for LA-MC-ICP-MS sulfur isotope analysis of sulfate minerals.

Key aspects of the approach included:

  • Reference Material Characterization: Identifying and validating YF-2 barite as a primary reference material, confirming its homogeneity through bulk EA-IRMS.
  • Standard-Sample-Bracketing (SSB): Correcting for instrumental drift and mass bias by alternating measurements between a known standard and the unknown sample.
  • Matrix Effect Testing: Analyzing a suite of sulfates—barite, celestine, barytocelestine, and anhydrite—to determine if a barite standard could accurately calibrate other sulfate species.
  • Parameter Optimization: Systematically varying laser spot size (32–90 μm), repetition rate (4–16 Hz), and energy fluence to find the "sweet spot" for minimizing isotopic fractionation.

Key Results and Validation

The $\delta^{34}S$ value for YF-2 barite was determined to be $18.1 \pm 0.4‰$ (2SD), which was perfectly reproduced by the LA-MC-ICP-MS protocol. The external reproducibility for most sulfate minerals was approximately $\pm 0.5‰$ (2SD), sufficient for distinguishing most geological processes.

Isotopic results for YF-2, NBS 127, and IAEA-SO-5 standards, demonstrating high precision and accuracy.

Measurements of international standards NBS 127 and IAEA-SO-5 using the YF-2 standard yielded results that overlapped with recommended values ($20.0 \pm 0.6‰$ and $0.2 \pm 0.6‰$, respectively). Notably, the WC barite sample showed highly variable $\delta^{34}S$ values at the micro-scale that were averaged out in bulk analysis, highlighting the necessity of in-situ methods to capture the true complexity of geological samples.

Discussion: Matrix Effects and Laser Tuning

A major finding was that matrix effects between different sulfate minerals are negligible under optimized conditions. This suggests that a single high-quality barite standard can be used to analyze a variety of other S-bearing sulfate matrices. However, the authors emphasize that while matrix effects between sulfates are minimal, there is a significant matrix effect between sulfides (like pyrite) and sulfates; one cannot use a sulfide standard to calibrate a sulfate sample.

For non-matrix matched analysis, fractionation can be minimized by using smaller beam sizes, lower repetition rates, and lower fluence. Future research into the "non-spectral sulfur oxidation effect" during ablation could further refine the accuracy of sulfur isotope measurements in complex mineral assemblages.

Summary updated

Abstract

Sulfate minerals are widely distributed in nature, and their sulfur isotopic signatures offer a largely untapped source of potential information for improving our understanding of magmatic, hydrothermal, and sedimentary processes. In this study, we describe an analytical procedure for measuring the sulfur isotopic compositions of natural sulfatebearing samples using a LA-MC-ICP-MS (laser ablation multiple collector inductively coupled plasma mass spectrometry) technique. YF-2 barite (BaSO4) from the Yongfu hydrothermal deposit yields a 34 S value of 18.1 0.4 (n = 11, 2SD), obtained by elemental analyzer-isotope ratio mass spectrometry (EA-IRMS), and has been adopted as the reference material for sulfur isotopic determination in this study. The sulfur isotopic ratios for NBS 127 and IAEA-SO-5 barium sulfate are validated by using YF-2 pressed powder tablets as the internal reference standard, and this analytical protocol yielded results that overlap with recommended values. The 34 S values obtained here for the YF-1, GTS, and DGD barites are similar to those recorded by EA-IRMS for these samples. WC barite displays highly variable sulfur isotopic compositions, although the average 34 S value for WC barite is similar to that obtained by EA-IRMS. Sulfates in the baritecelestine solid solution series and anhydrite were analyzed to determine the isotopic fractionation in varied matrices using both the RESOlution and GeoLasHD laser ablation systems. The analytical results suggest minimal sulfur isotopic fractionation between barite and other S-bearing matrices using both laser systems. For non-matrix matched sulfur isotope analysis, the ion signal intensity and laser parameters are important parameters that must be closely monitored. If sulfur isotopic fractionation is observed during sample ablation, this feature can be minimized by employing a smaller beam size, lower repetition rate and fluence output.