In situ optical coherence tomography of percutaneous implant-tissue interfaces in a murine model

Sabine Donner, Oliver Müller, Frank Witte, Ivonne Bartsch, Elmar Willbold, Tammo Ripken, Alexander Heisterkamp, Bodo Rosenhahn, Alexander KrügerBiomedizinische 2013 · DOI

TL;DR

This paper introduces a novel application of in vivo Optical Coherence Tomography (OCT) to non-invasively monitor the interface between percutaneous implants and surrounding tissue in a murine model. By developing specialized scanning and image processing techniques, the researchers were able to track tissue reactions over time, reducing the need for traditional, invasive histological analysis and offering a more detailed, 3D view of the implant-tissue integration.

What Problem Does This Paper Address?

Testing the biocompatibility of new implant coatings and designs is crucial for medical devices that penetrate the skin. Traditionally, this involves animal studies where the implant-tissue interface is analyzed through repeated, often lethal, biopsies. This method is resource-intensive, ethically challenging due to animal consumption, and can introduce artifacts during sample preparation, limiting the accuracy of morphological analysis. The paper addresses the need for a non-invasive, time-resolved method to monitor these interfaces, enabling a more efficient and detailed understanding of tissue response and potential inflammation.

Methods

The core of this work lies in the adaptation and application of Fourier-domain Optical Coherence Tomography (FD-OCT) for in vivo imaging of percutaneous implants in mice. Key methodological contributions include:

  • Spoke Pattern Scanning: To combat motion artifacts inherent in live animal imaging (due to breathing and pulse), a specialized "spoke" scanning pattern was employed. This pattern, centered on the implant, allows for rapid acquisition of cross-sectional images from different angles, effectively reducing blurring and distortion.
  • Image Segmentation and Undistortion: Sophisticated image processing techniques were developed to segment the skin surface and the implant base. This allowed for the automatic detection of key morphological features. Crucially, a method was devised to estimate the refractive index of the tissue in situ. This was achieved by modeling the curved distortion of the implant base in OCT images, which is influenced by ray refraction at the tissue surface and the tissue's refractive index. By fitting a model to the observed distortion, the refractive index could be estimated, enabling the correction of geometrical distortions and the calculation of true tissue thickness.
  • Time-Resolved 3D Imaging: By combining the spoke scanning with dense volume scans and image processing, the researchers achieved time-resolved, three-dimensional optical biopsies. This allowed for the monitoring of changes in tissue morphology around the implant at multiple time points (days 7 and 21 post-implantation, and post-mortem).

Datasets

The study utilized data from a murine model of hairless immunocompetent mice. In vivo OCT scans were performed at specific time points (days 7 and 21 post-implantation), and post-mortem scans were acquired upon signs of inflammation. No new benchmark datasets were introduced; rather, the paper focuses on the application of OCT to existing experimental setups.

Key Insights and Ideas

  • Non-invasive Monitoring is Feasible: The study demonstrates that OCT can effectively monitor implant-tissue interfaces in vivo, providing detailed morphological information without the need for invasive procedures. This significantly reduces animal suffering and resource expenditure.
  • Motion Artifacts are a Major Challenge, but Solvable: The paper highlights the significant impact of motion artifacts in in vivo OCT imaging of live animals. The developed spoke scanning scheme and subsequent motion compensation algorithms were crucial for obtaining usable data.
  • Refractive Index Estimation from Implant Geometry: A novel approach to estimate the tissue's refractive index directly from the geometry of the implanted base and the observed OCT image distortions was successfully implemented. This is a significant step towards accurate quantitative analysis of OCT data in complex biological tissues.
  • Morphological Changes Correlate with Inflammation: The time-resolved imaging revealed distinct morphological changes, such as increased tissue thickness and epithelial downgrowth, particularly in areas showing signs of inflammation. This suggests OCT can be a valuable tool for early detection and characterization of inflammatory responses.

Key Results

  • The developed FD-OCT system, combined with spoke scanning and image processing, successfully provided time-resolved 3D optical biopsies of the implant-tissue interface.
  • The image processing pipeline enabled automatic segmentation of the skin contour and implant anchor, and importantly, the estimation of the tissue's refractive index, with an overall estimated value of 1.39.
  • Qualitative observations showed clear differences in tissue morphology between healthy and inflamed sites, with inflammation leading to tissue swelling and altered structure.
  • Quantitative analysis of morphometric parameters (downgrowth, distance to pin, tissue thickness) revealed localized increases in these parameters at inflammation sites.

Limitations and Future Work

  • Resolution Limitations: The authors acknowledge that OCT, with a resolution of approximately 10 µm, does not reach cellular resolution, limiting its ability to visualize fine cellular details.
  • Refractive Index Heterogeneity: The hypothesis that refractive index might be an early indicator of inflammation could not be definitively answered, as the estimated overall refractive indices did not show consistent results. The authors suggest that future work could explore segmenting individual tissue layers and assigning different refractive indices to them.
  • Generalizability of Refractive Index Estimation: While successful in this model, further validation of the refractive index estimation method across different tissue types and implant geometries would be beneficial.
  • Future Studies: The authors propose further studies to investigate the significant correlations found between morphometric parameters and sensitivity to inflammation, potentially leading to better predictive models for implant success. They also suggest exploring the potential of using refractive index variations as an early indicator of inflammation.

Summary updated

Abstract

Novel surface coatings of percutaneous implants need to be tested in biocompatibility studies. The use of animal models for testing usually involves numerous lethal biopsies for the analysis of the implant-tissue interface. In this study, optical coherence tomography (OCT) was used to monitor the reaction of the skin to a percutaneous implant in an animal model of hairless but immunocompetent mice. In vivo optical biopsies with OCT were taken at days 7 and 21 after implantation and post mortem on the day of noticeable inflammation. A Fourier-domain OCT was programmed for spoke pattern scanning schemes centered at the implant midpoint to reduce motion artifacts during in vivo imaging. Image segmentation allowed the automatic detection and morphometric analysis of the skin contour and the subcutaneous implant anchor. On the basis of the segmentation, the overall refractive index of the tissue within one OCT data set was estimated as a free parameter of a fitting algorithm, which corrects for the curved distortion of the planar implant base in the OCT images. OCT in combination with the spoke scanning scheme and image processing provided time-resolved three-dimensional optical biopsies around the implants to assess tissue morphology.
BibTeX
@inproceedings{donner2013situ,
  author = {Sabine Donner and Oliver Müller and Frank Witte and Ivonne Bartsch and Elmar Willbold and Tammo Ripken and Alexander Heisterkamp and Bodo Rosenhahn and Alexander Krüger},
  title = {{In situ optical coherence tomography of percutaneous implant-tissue interfaces in a murine model}},
  booktitle = {Biomedizinische},
  year = {2013},
  doi = {10.1515/bmt-2012-0044},
}