In situ mechanostimulation of biohybrid millirobots for enhanced cell functionality and delivery

Jianhua Zhang, Xianqiang Bao, Zhou Zhu, Rongjing Zhang, Chunxiang Wang, Mingtong Li, Kaichen Xu, Yunfeng He, Dietmar W. Hutmacher, Ziyu Ren, Metin SittiScience 2026 · DOI

TL;DR

Researchers have developed "biohybrid millirobots" – tiny, soft robots made from biocompatible materials and embedded with cells – that can both deliver cells to specific locations and provide mechanical stimulation to enhance cell function. This dual capability holds promise for improving cell-based therapies by ensuring cells not only reach their target but also perform optimally.

What Problem Does This Paper Address?

Delivering cells for therapeutic purposes, like regenerating damaged tissue, faces a major hurdle: getting enough viable cells to the precise location and ensuring they function effectively once there. Current methods often struggle with low cell concentration at the target site due to biological fluid flow, and even when cells arrive, they may not perform optimally because they lack the necessary biological and physical cues from their native environment. This paper tackles this by creating a system that combines precise cell delivery with in situ mechanical stimulation, mimicking natural cellular environments to boost cell functionality.

Methods

The core innovation is a "perforated, soft millirobot" fabricated from magnetic particles (NdFeB@SiO2) embedded in a biocompatible silicone (PDMS). These millirobots are designed with intricate pore structures to maximize cell adhesion and tissue ingrowth.

Key techniques include:

  • Magnetic Actuation: External magnetic fields are used to control the millirobots' movement and induce reversible contraction-relaxation cycles. This mimics muscle training, providing mechanical stimulation.
  • Protein Modification: The millirobot surfaces are modified with fibronectin to enhance cell adhesion and integration.
  • Laser Micromachining: Used to create precise perforated structures in the millirobot sheets.
  • Finite Element Analysis (FEA): Employed to simulate the mechanical deformation of the millirobots under magnetic fields, predicting the strain and stress applied to cells.
  • Integrated Robotic Platform: A system combining magnetic actuation with ultrasound (US) imaging for real-time tracking and precise delivery of the millirobots.
  • Cell Culture & Differentiation Assays: Various cell types (C2C12 myoblasts, hMSCs, 3T3 fibroblasts) were used to evaluate cell viability, proliferation, differentiation, and myotube contraction under different conditions.
  • Histological and Immunohistochemical Analysis: Used to assess cell orientation, protein expression (YAP, PAX7, MyoD1, MHC), and tissue integration.
  • Ex Vivo and In Vivo Models: Experiments were conducted in ex vivo pig liver and mouse muscle models, as well as in vivo rat models for toxicological assessment.

Datasets

Not discussed in the paper.

Key Insights and Ideas

  • Dual Functionality is Key: The paper demonstrates that combining in situ mechanostimulation with targeted cell delivery is more effective than delivery alone. Cells not only reach their destination but also become more functional.
  • Mimicking Muscle Training Works: The contraction-relaxation cycles of the millirobots effectively mimic natural muscle exercise, leading to enhanced muscle cell orientation, myotube contraction, and differentiation.
  • Perforated Design Enhances Integration: The porous structure of the millirobots is crucial for promoting cell adhesion, tissue ingrowth, and creating a more cell-permissive environment.
  • Ultrasound Guidance is Essential for Precision: Integrating magnetic actuation with ultrasound imaging allows for real-time tracking and highly precise delivery of these biohybrid robots, even into narrow biological channels.
  • Soft Robots Adapt to Complex Environments: The soft, deformable nature of the millirobots allows them to navigate and function effectively in complex, confined spaces like the bile ducts of a pig liver.

Key Results

  • Enhanced Cell Functionality: Mechanostimulation significantly improved muscle cell orientation (alignment index up to 0.98), myotube contraction (18.83 ± 2.80 µm vs. 2.01 ± 0.49 µm), and myocyte differentiation (indicated by increased PAX7, MyoD1, and MHC protein expression).
  • Improved Cell Proliferation and Viability: Actuation led to higher cell proliferation rates compared to rest conditions, with cell viability remaining high (>85%).
  • Precise Delivery: The 2D millirobots successfully navigated and delivered cells into narrow regions (as small as 0.5 mm) in an ex vivo pig liver model.
  • Biocompatibility: In vivo toxicological assessments showed excellent local and systemic biocompatibility, with no pathological abnormalities observed in major organs.
  • Locomotion Speed: The 2D cell-sheet millirobots exhibited a higher locomotion speed (0.24 ± 0.05 mm/s) compared to the 3D cell-laden hydrogel millirobots (0.08 ± 0.02 mm/s).

Limitations and Future Work

The authors acknowledge several limitations and outline future directions:

  • Material Degradation: The current millirobots use non-degradable materials (PDMS and NdFeB@SiO2). Future work will focus on developing biodegradable and biocompatible materials for clinical translation.
  • Complex Actuation Modes: The current study primarily uses a simple contraction-relaxation mode. Further exploration of various mechanical stimulation patterns is needed.
  • Integrated Ex Vivo Platform: Developing a fully integrated platform that combines targeted delivery, in situ stimulation, cellular proliferation, and self-adhesion within a single tissue sample remains a challenge.
  • In Vivo Demonstrations: While ex vivo and biosafety studies are promising, controlled in vivo demonstrations are crucial. This includes using biodegradable constructs, achieving sufficient magnetic torque at depth, and developing multimodal imaging and closed-loop control.
  • Autologous Cells and Immunodeficient Hosts: For more accurate evaluation of long-term cell viability and integration, future studies will utilize autologous cells or immunodeficient hosts.

Summary updated

Abstract

This study proposes a perforated, soft millirobot with dual functions: in situ mechanostimulation to enhance cell functionality and local cell delivery. Following protein modification and silica coating, the soft millirobots exhibit excellent biocompatibility, promoting cell adhesion and tissue ingrowth within their perforated architectures under both in vitro and in vivo conditions. They can apply in situ mechanostimulation to various cellular morphologies, including two-dimensional (2D) cell sheets, 3D cell-laden hydrogels, and ex vivo tissue models. The mechanical stimulation improves the functionality of muscle cells by enhancing cellular orientation, myotube contraction, and myocyte differentiation. In parallel, we develop an integrated robotic platform combining magnetic actuation with ultrasound imaging. It demonstrates the proof of principle that delivers 2D cell-sheet and 3D cell-laden biohybrid millirobots to narrow regions in an ex vivo pig liver model. This work expands the potential applications of soft millirobots in mechanobiology studies and future cell-based therapies.
BibTeX
@inproceedings{zhang2026situ,
  author = {Jianhua Zhang and Xianqiang Bao and Zhou Zhu and Rongjing Zhang and Chunxiang Wang and Mingtong Li and Kaichen Xu and Yunfeng He and Dietmar W. Hutmacher and Ziyu Ren and Metin Sitti},
  title = {{In situ mechanostimulation of biohybrid millirobots for enhanced cell functionality and delivery}},
  booktitle = {Science},
  year = {2026},
  doi = {10.1126/sciadv.adx9616},
}
Figure