In-Fiber Mach-Zehnder Interferometer Based on Three-Core Fiber for Measurement of Directional Bending

Lei Ding, Yu Li, Cai Zhou, Min Hu, Yuli Xiong, Zhongliang Zeng2019 · DOI

TL;DR

Researchers have developed a novel in-fiber bending sensor using a three-core fiber (TCF) Mach-Zehnder interferometer (MZI). This sensor offers high sensitivity and directional measurement capabilities for bending, making it a promising candidate for applications in biomedical sensing and robotics.

What Problem Does This Paper Address?

Accurate measurement of bending, especially its direction, is crucial in various fields, including robotics, structural monitoring, and biomedical applications like gait analysis. Traditional methods often rely on Fiber Bragg Gratings (FBGs) or Long Period Fiber Gratings (LPFGs), which can be complex and expensive to fabricate, and sometimes lack sufficient sensitivity or directional discrimination. While some in-fiber interferometers offer directional sensing, there's a continuous need for more sensitive, cost-effective, and easily fabricated solutions. This paper aims to address this by proposing and demonstrating a TCF-based MZI that leverages the unique structure of the three-core fiber for enhanced directional bending sensitivity.

Methods

The core of this research lies in the fabrication and characterization of an in-fiber Mach-Zehnder interferometer (MZI) using a three-core fiber (TCF). The TCF was fusion-spliced between two standard single-mode fibers (SMFs) with a lateral core-offset. This offset is critical for exciting cladding modes that interfere with the core mode, forming the MZI.

Two sensor configurations (Sensor 1 and Sensor 2) were created by varying the position of the TCF cores relative to the neutral plane of the fiber during the fusion splicing process. This structural difference is hypothesized to influence the sensor's response to bending.

The experimental setup involved a swept-source laser to interrogate the MZI and an optical spectrum analyzer (OSA) to measure the transmission spectrum. Bending was applied using a rotatable clamp and a precisely controlled micrometer screw, allowing for controlled curvature and direction. The researchers systematically tested the sensors under various bending directions (0°, 90°, 180°) and curvatures (0 to 1 m⁻¹).

Datasets

Not discussed in the paper. The experiments involved controlled laboratory measurements of the fabricated sensor's response to applied bending and temperature.

Key Insights and Ideas

  • TCF as a Bending Sensor Platform: The paper demonstrates that the inherent asymmetry introduced by the three cores in a TCF, when combined with a core-offset splice, can be effectively utilized to create a highly sensitive directional bending sensor.
  • Core Position is Key: The precise location of the eccentric core within the TCF relative to the neutral plane significantly impacts the bending sensitivity. A core further from the neutral plane leads to a greater change in optical path length upon bending, thus increasing sensitivity.
  • Directional Sensitivity: The sensor exhibits distinct responses to bending at different directions. Bending along the 0° and 180° axes (where the eccentric core is significantly strained) results in substantial wavelength shifts, while bending at 90° (where the core is closer to the neutral plane) shows minimal shift.
  • Simplicity and Cost-Effectiveness: The fabrication process, involving standard fusion splicing techniques, is relatively simple and inexpensive compared to some existing FBG-based directional sensors.
  • Potential for Biomedical Applications: The compact size, high sensitivity, and directional measurement capability make this sensor attractive for applications requiring precise monitoring of body movements, such as joint angle tracking.

Key Results

  • High Bending Sensitivity: Sensor 1, with a core further from the neutral axis, achieved bending sensitivities of 15.36 nm/m⁻¹ at 0° bending and -20.48 nm/m⁻¹ at 180° bending. Sensor 2, with a core closer to the neutral axis, showed sensitivities of 3.11 nm/m⁻¹ (0°) and -5.29 nm/m⁻¹ (180°). Sensor 1 was approximately 4-5 times more sensitive than Sensor 2.
  • Directional Discrimination: The sensor clearly distinguished between bending directions, with significant wavelength shifts observed at 0° and 180°, and negligible shifts at 90°.
  • Linearity: The wavelength shift showed a good linear relationship with the applied curvature, with correlation coefficients (R²) generally above 0.989 for the 0° and 180° directions.
  • Low Temperature Sensitivity: The temperature sensitivities of the interference minima were measured to be 0.043 nm/°C and 0.041 nm/°C, indicating that temperature has a minimal impact on the bending measurements.

Limitations and Future Work

  • Optical Loss: The paper acknowledges that the TCF-based MZI sensor experienced increased optical losses, which could affect performance and potentially lead to discrepancies between theoretical analysis and experimental data.
  • Fabrication Fragility: The bare fiber sensor is fragile, requiring careful handling during fabrication and splicing.
  • Simplified Bending Simulation: The experimental setup simulated bending in a controlled manner. Real-world bending can be more complex, involving simultaneous bending in multiple directions and at different points along the sensor.
  • Future Work: The authors plan to focus on miniaturized packaging for the TCF-based MZI sensor and explore its application in biomedical sensing equipment. Improving repeatability and reducing optical system losses through advanced fabrication techniques are also key future directions.

Summary updated

BibTeX
@misc{ding2019fiber,
  author = {Lei Ding and Yu Li and Cai Zhou and Min Hu and Yuli Xiong and Zhongliang Zeng},
  title = {{In-Fiber Mach-Zehnder Interferometer Based on Three-Core Fiber for Measurement of Directional Bending}},
  year = {2019},
  doi = {10.3390/s19010205},
}

Loading related content...

Figure