Abstract
Purpose: To compare the effects of different annotation strategies on the performance of Radiomics models in identifying COVID-19. Methods: A total of 775 CT scans were retrospectively collected from 5 hospitals in China between Jan 19 and Mar 26, 2020, including 310 COVID-19 scans and 465 other community-acquired pneumonia (CAP) scans. Coarse annotation which labels the major lesions on certain CT slides and fine annotation which delineates the contour of lesions on each slide was performed on CT images. Four feature selection methods and four machine learning algorithms were then applied in combinations to develop Radiomics models on different sizes of datasets, including small (56 CT scans) and large (56 + 489 CT scans). Model performance was evaluated by ROC curve, PR curve, and other diagnostic metrics on an external test set. Results: Differences between coarse and fine annotated data were quantitatively analyzed by a Dice index of 0.689, an average Hausdorff distance of 3.7%, and an average volume difference of 5.8%. Inaccurate segmentations were observed in coarse annotated images, including relatively smaller ROI and missed delineation of ground-glass opacity. Fine annotation enabled an over better performance of Radiomics models while enlarged dataset size could remedy the influence of coarse annotation. L1-LR-MLP was selected as the optimal combination for modeling. Conclusions: Fine annotation generally enables a better model performance in the identification of COVID-19 while the efficient coarse annotation strategy could also be applied to achieve the equivalent diagnostic performance by expanding the training dataset, especially in urgent scenarios.
Introduction
In the development of medical AI, the "ground truth" often serves as a significant bottleneck. Training models to identify COVID-19 from CT scans typically requires expert radiologists to painstakingly outline every lesion—a process known as fine annotation. While precise, this is labor-intensive, often taking an hour per patient. Coarse annotation, frequently automated, offers a faster alternative but at the cost of precision. This study investigates whether increased data volume can compensate for the lower quality of coarse annotations in Radiomics-based screening.
Methods
The research team compared two primary annotation strategies:
- Fine Annotation: Manual contouring of every lesion performed by ten senior radiologists.
- Coarse Annotation: Automated delineation using a pre-trained deep learning algorithm, requiring approximately 30 seconds per case.
From these annotations, 1,454 Radiomics features (including shape, intensity, and texture) were extracted using the pyRadiomics library. The researchers then evaluated 64 combinations of four feature selection methods (e.g., LASSO, L1-LR) and four machine learning classifiers (LR, MLP, SVM, and XGBoost) across "small" (56 scans) and "large" (545 scans) dataset sizes.
Datasets
The study utilized a multi-center approach with 775 CT scans collected from five hospitals in China. This included 310 COVID-19 scans and 465 community-acquired pneumonia (CAP) scans, the latter serving as a control group to ensure the AI specifically identified COVID-19 rather than general pneumonia.
An external validation set of 230 scans from Jinan Infectious Disease Hospital was kept entirely separate to test the models' real-world robustness.
Key Results and Insights
Quantity Remedies Quality
On small datasets, the performance gap between fine and coarse labels was substantial (AUROC 0.864 vs. 0.707). However, as the dataset size increased, this gap nearly vanished. On the large dataset, the coarse-labeled model (LDRough) achieved an AUROC of 0.899, closely matching the fine-labeled model's (LDFine) 0.904. This suggests that data volume can "smooth out" the noise introduced by less accurate automated labeling.
Model Stability and Selection
Models trained on larger datasets were significantly more stable across different algorithmic combinations. While small-data models fluctuated wildly depending on the classifier used, large-data models remained consistent. The combination of L1-LR for feature selection and MLP (Multi-Layer Perceptron) for classification emerged as the most robust architecture for this task.
Annotation Discrepancies
Quantitatively, coarse labels had a Dice index of only 0.689 compared to fine labels. Automated coarse labels specifically struggled with early-stage, inconspicuous lesions and fuzzy margins (ground-glass opacities), which radiologists were better equipped to identify.
Conclusion
While fine annotation remains the gold standard for small datasets, expanding the training data volume can effectively mitigate the inaccuracies of automated coarse labeling. In urgent clinical scenarios, the 120-fold efficiency gain of coarse annotation makes it a viable strategy for rapid AI deployment without significant loss in diagnostic performance. Future work may explore "human-in-the-loop" systems to find an optimal balance between speed and precision.
Summary updated