Impact of Pulmonary Vein Isolation on Atrial Fibrillation Organisation: Correlation of Intracardiac and Surface Electrocardiogram Measures

Nazifa Ahsan, Arunashis Sau, Joseph Barker, Rajeshkumar M. Neerahoo, Norman Qureshi, Michael Koa‐Wing, Daniel Keene, Louisa Malcolme‐Lawes, David Lefroy, Nick Linton, Phang Boon Lim, Amanda Varnava, Zachary I. Whinnett, Prapa Kanagaratnam, Danilo P. Mandic, Nicholas S. Peters, Fu Siong NgJournal of Cardiovascular Electrophysiology 2025 · DOI

TL;DR

This study reveals that pulmonary vein isolation (PVI) in atrial fibrillation (AF) patients leads to more organized electrical activity in the atria. Crucially, this increased atrial organization is reflected in the regularity of the heart's ventricular rhythm, which can be measured non-invasively using surface ECGs, suggesting a potential new way to assess AF complexity.

What Problem Does This Paper Address?

Atrial fibrillation (AF) is a complex arrhythmia characterized by chaotic electrical activity in the atria. Current understanding suggests AF exists on a spectrum from relatively organized focal drivers to highly disorganized multiple wavelet re-entry. Pulmonary vein isolation (PVI) is a standard treatment that targets the pulmonary veins, which are often the source of AF triggers. While PVI is effective at reducing AF burden, its impact on the organization of the underlying atrial electrical activity is not fully understood. This paper aims to investigate how PVI affects AF organization and, importantly, to determine if changes in atrial organization can be detected non-invasively by analyzing the ventricular response on a surface electrocardiogram (ECG). This is significant because a non-invasive marker of AF organization could help tailor treatment strategies and predict outcomes.

Methods

The researchers employed a retrospective cohort study design, analyzing data from 171 patients who underwent first-time PVI for persistent or longstanding persistent AF. They used two key measures to quantify AF organization: Shannon entropy (ShEn) and Sample entropy (SampEn). These are signal processing techniques that measure the complexity and regularity of electrical signals. ShEn quantifies the distribution of signal amplitudes, with higher values indicating more complex signals. SampEn measures the prevalence of similar patterns within the signal, where a higher SampEn indicates more irregularity. These measures were calculated from intracardiac electrograms recorded from the coronary sinus (CS) before and after PVI.

To assess the ventricular response, they analyzed RR interval (RRI) variability and irregularity from surface ECGs. This included measures like the percentage of RRIs differing by more than 50 ms (pNN50) and normalized measures of standard deviation of RRIs (SD RRI) and SampEn. The core of their analysis involved correlating the changes in atrial entropy (pre- vs. post-PVI) and the correlations between atrial entropy and ventricular response metrics.

Datasets

The study utilized data from 171 patients undergoing PVI at Imperial College Healthcare NHS Trust between 2014 and 2022. This is a clinical dataset, not a benchmark dataset, and no new datasets were introduced.

Key Insights and Ideas

  • PVI "tidies up" atrial chaos: The most striking finding is that PVI significantly reduces both ShEn and SampEn in the coronary sinus electrograms. This directly supports the hypothesis that PVI leads to a more organized electrical state in the atria.
  • Surface ECGs can "see" atrial organization: The study demonstrates a significant correlation between atrial entropy (a measure of intracardiac organization) and ventricular response regularity (measured by surface ECG). This is a crucial insight, suggesting that changes in the atria's electrical chaos are mirrored in the heart's overall rhythm.
  • Ventricular irregularity is a proxy for atrial chaos: The findings imply that the more disorganized the atrial electrical activity, the more irregular the ventricular response will be, and vice-versa. This opens the door for non-invasive assessment of AF organization.

Key Results

  • Following PVI, there was a statistically significant decrease in atrial ShEn across all CS channels (e.g., CS 3-4: pre-ablation = 2.796 ± 0.707 vs. post-ablation = 2.628 ± 0.685, p < 0.001).
  • Similarly, atrial SampEn also significantly decreased post-PVI (e.g., CS 3-4: pre-ablation = 0.907 ± 0.512 vs. post-ablation = 0.790 ± 0.446, p < 0.001).
  • Significant correlations were observed between atrial entropy and ventricular response metrics both pre- and post-ablation. For instance, atrial SampEn (CS 3-4) correlated with the percentage of RRIs > 50 ms difference (r = 0.077, p = 0.008) and normalized mean RRI difference (r = 0.144, p < 0.001).

Limitations and Future Work

The authors acknowledge several limitations:

  • Limited spatial resolution: Coronary sinus catheters only record local left atrial signals, which may not fully represent bi-atrial activity.
  • Anesthetic effects: General anesthesia used during procedures might have influenced RRI variability measurements.
  • Catheter positioning variability: Differences in CS catheter placement could affect electrogram morphology and thus entropy values.
  • Lack of a gold standard: There isn't a universally accepted "gold standard" for measuring AF organization that directly links to ablation outcomes.
  • No re-mapping post-PVI: The study couldn't definitively rule out the development of atrial flutter or macro-reentrant tachycardia after PVI without re-mapping.

Future research is needed to explore whether non-invasive assessment of AF organization using RRI variability and irregularity can be reliably associated with clinically meaningful outcomes. The authors suggest further investigation into how these ECG-based measures can be used to tailor ablation strategies to specific AF electrophenotypes.

Summary updated

Abstract

The reduction in atrial ShEn and SampEn post-PVI indicates increased AF organization. The significant correlation between atrial entropy and ventricular variability suggests that AF organization affects ventricular response, assessed via surface ECG metrics. These findings highlight the potential of ECG-based measures as proxies for intracardiac AF organization.
BibTeX
@article{ahsan2025impact,
  author = {Nazifa Ahsan and Arunashis Sau and Joseph Barker and Rajeshkumar M. Neerahoo and Norman Qureshi and Michael Koa‐Wing and Daniel Keene and Louisa Malcolme‐Lawes and David Lefroy and Nick Linton and Phang Boon Lim and Amanda Varnava and Zachary I. Whinnett and Prapa Kanagaratnam and Danilo P. Mandic and Nicholas S. Peters and Fu Siong Ng},
  title = {{Impact of Pulmonary Vein Isolation on Atrial Fibrillation Organisation: Correlation of Intracardiac and Surface Electrocardiogram Measures}},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2025},
  doi = {10.1111/jce.70044},
}
Figure