Impact of fiber-optic laryngoscopy on the weaning process from mechanical ventilation in high-risk patients for postextubation stridor

Malcolm Lemyze, Emmanuelle Durville, Mehdi Meddour, Marie Jonard, Johanna Temime, Stéphanie Barailler, Didier Thévenin, Jihad MallatMedicine 2017

TL;DR

This pilot study challenges the standard practice of using corticosteroids for patients at high risk of postextubation stridor. It proposes fiber-optic laryngoscopy (FOL) as a more effective and faster strategy, significantly reducing mechanical ventilation duration and avoiding stridor by identifying a specific laryngeal "V sign."

What Problem Does This Paper Address?

Critically ill patients on mechanical ventilation are at risk of developing postextubation stridor, a condition where airway swelling after tube removal causes noisy breathing and potential respiratory failure. A common clinical test, the cuff leak test (CLT), is used to predict this risk. A "positive" CLT (indicating a small air leak around the tube) traditionally leads to treatment with corticosteroids, with extubation delayed for 24-48 hours to allow the medication to work. However, the actual anatomical cause of a positive CLT isn't always clear, and the effectiveness and potential side effects of prolonged corticosteroid use in this context are questioned. This paper investigates whether a direct visualization of the larynx via fiber-optic laryngoscopy (FOL) can provide a more accurate assessment and a faster, safer path to extubation.

Methods

This was a prospective, observational pilot study conducted in a 15-bed ICU over one year. All intubated patients who passed a spontaneous breathing trial (SBT) underwent a cuff leak test (CLT). If the CLT was positive (cuff leak volume < 110 mL), patients were either evaluated with fiber-optic laryngoscopy (FOL) by a trained practitioner or received corticosteroids (methylprednisolone 20mg every 4 hours). The FOL procedure involved passing a flexible bronchoscope to visualize the pharynx and larynx, looking for edema, ulcerations, and specifically a "V sign" (a V-shaped opening of the anterior vocal cords). If the "V sign" was present, immediate extubation was performed. The study compared outcomes between the FOL group and the corticosteroid group, focusing on duration of mechanical ventilation, time to extubation, and incidence of stridor or reintubation.

Datasets

Not discussed in the paper.

Key Insights and Ideas

  • Challenging the Status Quo: The study directly questions the efficacy of the standard corticosteroid treatment for positive CLT, suggesting it may unnecessarily prolong ventilation without clear benefit.
  • Anatomical Insight: A positive CLT doesn't necessarily mean severe vocal cord swelling. FOL revealed that edema of the arytenoids and posterior larynx, often compressed by the endotracheal tube and nasogastric tube, was a common finding.
  • The "V Sign" as a Predictor: The identification of a specific "V sign" on FOL, representing a clear anterior V-shaped opening of the vocal cords, proved to be a highly reliable indicator for safe and immediate extubation, preventing stridor.
  • Efficiency Gains: FOL-guided extubation significantly reduced the time from a successful SBT to actual extubation, leading to shorter overall mechanical ventilation durations.
  • Minimizing Harm: By avoiding prolonged corticosteroid use, this strategy potentially reduces associated risks like delirium, dysglycemia, and superinfections.

Key Results

  • Out of 233 patients, 34 (14.6%) had a positive CLT.
  • Seventeen patients received corticosteroids, and 17 underwent FOL.
  • In the corticosteroid group, 53% still had a positive CLT after 24 hours, and mechanical ventilation was prolonged (7 days vs. 4 days in the FOL group, P=0.01).
  • The time between SBT and extubation was significantly longer in the corticosteroid group (30 hours vs. 1.5 hours in the FOL group, P<0.001).
  • In the FOL group, all 26 patients evaluated (including those from the corticosteroid group who later underwent FOL) showed findings like arytenoid edema.
  • Crucially, all 26 patients who exhibited the "V sign" on FOL were immediately extubated without developing stridor or respiratory failure.

Limitations and Future Work

The authors acknowledge several limitations:

  • Observational Design: The study is observational and not randomized, meaning selection bias cannot be entirely ruled out. The decision to use FOL or corticosteroids was based on the availability of the FOL practitioner.
  • Single-Center Study: The findings are from a single center, which may limit generalizability.
  • Practitioner Skill: The FOL procedure was performed by a single, experienced practitioner. The study notes that standard flexible laryngoscopes might be challenging for less experienced users, but they used a bronchoscope with higher suctioning capacity.

Future work suggested includes a large, multicenter randomized controlled trial to confirm these findings and further validate the FOL-based strategy and the "V sign" as a reliable extubation criterion.

Summary updated

Abstract

The objective of this study was to assess the impact of fiber-optic laryngoscopy (FOL) on the weaning process from mechanical ventilation in critically ill patients with a positive cuff leak test (CLT) as compared with the current recommended strategy based on corticosteroids.In this prospective observational pilot study conducted over a 1-year period in a 15-bed ICU, CLT was systematically performed before extubation in all intubated patients having passed a spontaneous breathing trial (SBT). After the endotracheal tube cuff was deflated, cuff leak volume (CLVol) was assessed during assisted controlled ventilation. When CLT was positive (CLVol < 110 mL), patients either were evaluated using FOL by our half-time FOL-practitioner when present, or received corticosteroids.Among the 233 patients included, 34 (14.6%) had a positive CLT that hampered extubation. Seventeen were treated by corticosteroids and 17 were evaluated by FOL. In the corticosteroids group, the CLVol was still <110 mL at 24 hours in 9 patients (53%). Corticosteroids strategy merely prolonged the total duration of mechanical ventilation (7 [4-11] vs 4 [2-6] days, P = 0.01) by increasing the time between successful SBT and the moment when extubation was effectively achieved (30 [24-60] vs 1.5 [1-2] hours, P < 0.001). This resulted in 2 self-extubations (12%) and 9 FOL-guided extubations (53%) in the corticosteroids group. Massive swelling of the arytenoids was the most common feature shown by FOL. The patients evaluated by FOL who exhibited the thin anterior V-shaped opening of the vocal cords-the V sign-(n = 26, 100%) were immediately extubated without any stridor or respiratory failure afterward.In this pilot study, a FOL-based extubation strategy was feasible and reliable, and significantly reduced the duration of mechanical ventilation in patients with a positive CLT. We describe the "V sign" of FOL that safely allows a successful prompt extubation in patients considered at high risk for postextubation stridor.
BibTeX
@inproceedings{lemyze2017impact,
  author = {Malcolm Lemyze and Emmanuelle Durville and Mehdi Meddour and Marie Jonard and Johanna Temime and Stéphanie Barailler and Didier Thévenin and Jihad Mallat},
  title = {{Impact of fiber-optic laryngoscopy on the weaning process from mechanical ventilation in high-risk patients for postextubation stridor}},
  booktitle = {Medicine},
  year = {2017},
  doi = {10.1097/md.0000000000005971},
}
Figure