Imaging Linearity Modeling and Optimization of Capacitive Division Image Readout (C-DIR) for Microchannel Plate Imaging Detectors
Lists
Only you see this
Abstract
A 3-D lumped parameter circuit model based on the nodal analysis to simulate signal propagation and position response characteristics of capacitive division image readout (C-DIR) is proposed. The current pulses, charge collection efficiency, and position reconstruction patterns are calculated for different electrical parameters (charge division capacitor <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$C_{c}$ </tex-math></inline-formula> , perimeter capacitor <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$C_{p}$ </tex-math></inline-formula> , diagonal capacitor <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$C_{d}$ </tex-math></inline-formula> , electrode parasitic capacitor <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$C_{s}$ </tex-math></inline-formula> , and the sheet resistance of the resistive layer <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$R_{\mathrm {Ge}}$ </tex-math></inline-formula> ), and their influence on imaging linearity is investigated. The simulation results show that <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$R_{\mathrm {Ge}}$ </tex-math></inline-formula> affects the amplitude, pulsewidth, and polarity of the current pulse in the C-DIR. The sheet resistance of the resistive layer needs to be larger than 10 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\text{M}\Omega $ </tex-math></inline-formula> for the charge to be efficiently collected by the readout electronics. Several capacitance ratios ( <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$C_{c}/C_{p}$ </tex-math></inline-formula> , <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$C_{c}/C_{s}$ </tex-math></inline-formula> , and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$C_{c}/C_{d})$ </tex-math></inline-formula> mainly affect the imaging linearity. It has been found that to obtain good detector imaging performance, <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$C_{c}/C_{p}$ </tex-math></inline-formula> should be less than 0.01, <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$C_{c}/C_{s}$ </tex-math></inline-formula> should be larger than 100, and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$C_{c}/C_{d}$ </tex-math></inline-formula> should be larger than 10, and when <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$R_{\mathrm {Ge}}$ </tex-math></inline-formula> is larger than 10 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\text{M}\Omega $ </tex-math></inline-formula> , the imaging nonlinearity (rms) can be less than 1%. The reliability of the simulation results was verified by experimental measurements of a prototype C-DIR detector designed by ourselves. An optimized imaging performance with imaging nonlinearity (rms) of 2.18% was achieved.
BibTeX
@article{yang2023imaging,
author = {Kai Yang and Yonglin Bai and Bingli Zhu and Bo Wang and Weiwei Cao and Shengdan Zhang and Xiaohong Bai and Jinkun Zheng and Yang Yang and Zhe Chen},
title = {{Imaging Linearity Modeling and Optimization of Capacitive Division Image Readout (C-DIR) for Microchannel Plate Imaging Detectors}},
journal = {IEEE Transactions on Nuclear Science},
year = {2023},
doi = {10.1109/tns.2023.3265720},
}Loading related content...