ILEE ROBUST project: Development of a multiple rocking steel structural system

Jia L-j, Rong Xie, Ke Fan, Ping Xiang, Xuran Zhao, G MacRae, G. Charles Clifton, Shahab Ramhormozian, Yan Z, Rajesh P. DhakalUniversity 2020

Abstract

In recent years, rocking isolation has become an effective approach to improve seismic performance of steel and
\nreinforced concrete structures. These systems can mitigate structural damage through rigid body displacement and thus
\nrelatively low requirements for structural ductility, which can significantly improve seismic resilience of structures and
\nreduce repairing costs after strong earthquakes. A number of base rocking structural systems with only a single rocking
\ninterface have been proposed. However, these systems can have significant high mode effect for high rise structures due
\nto the single rocking interface. This RObust BUilding SysTem (ROBUST) project is a collaborative China-New Zealand
\nproject sponsored by the International Joint Research Laboratory of Earthquake Engineering (ILEE), Tongji University,
\nand a number of agencies and universities within New Zealand including the BRANZ, Comflor, Earthquake Commission,
\nHERA, QuakeCoRE, QuakeCentre, University of Auckland, and the University of Canterbury. A number of structural
\nconfigurations will be tested [1, 2], and non-structural elements including ceilings, infilling walls, glazed curtain walls,
\nprecast concrete panels, piping system will also be tested in this project [3].
\nWithin this study, a multiple rocking column steel structural system was proposed and investigated mainly by Tongji
\nteam with assistance of NZ members. The concept of rocking column system initiates from the structure of Chinese
\nancient wooden pagoda. In some of Chinese wooden pagodas, there are continuous core columns hanged only at the top
\nof each pagoda, which is not connected to each stories. This core column can effectively avoid collapse of the whole
\nstructure under large storey drifts. Likewise, there are also central continuous columns in the newly proposed steel rocking
\ncolumn system, which can avoid weak story failure mechanism and make story drifts more uniform. In the proposed
\nrocking column system, the structure can switch between an elastic rigidly connected moment resisting frame and a
\ncontrolled rocking column system when subjected to strong ground motion excitations. The main seismic energy can be
\ndissipated by asymmetric friction beam–column connections, thereby effectively reducing residual displacement of the
\nstructure under seismic loading without causing excessive damage to structural members. Re–centering of the structure
\nis provided not only by gravity load carried by rocking columns, but also by mould coil springs.
\nTo investigate dynamic properties of the proposed system under different levels of ground excitations, a full-scale threestory steel rocking column structural system with central continuous columns is to be tested using the International joint
\nresearch Laboratory of Earthquake Engineering (ILEE) facilities, Shanghai, China and an analytical model is established.
\nA finite element model is also developed using ABAQUS to simulate the structural dynamic responses. The rocking
\ncolumn system proposed in this paper is shown to produce resilient design with quick repair or replacement.
BibTeX
@inproceedings{lj2020ilee,
  author = {Jia L-J and Rong Xie and Ke Fan and Ping Xiang and Xuran Zhao and G MacRae and G. Charles Clifton and Shahab Ramhormozian and Yan Z and Rajesh P. Dhakal},
  title = {{ILEE ROBUST project: Development of a multiple rocking steel structural system}},