iERM: An Interpretable Deep Learning System to Classify Epiretinal Membrane for Different Optical Coherence Tomography Devices: A Multi-Center Analysis

Kai Jin, Yan Yan, Shuai Wang, Ce Yang, Menglu Chen, Xindi Liu, Hiroto Terasaki, Tun-Hang Yeo, Neha Gulab Singh, Yao Wang, Juan YeJournal of Clinical Medicine 2023

TL;DR

This paper introduces iERM, a novel two-stage deep learning system that accurately classifies the severity of epiretinal membranes (ERM) from OCT images. By integrating human-derived segmentation of key retinal features, iERM not only improves diagnostic performance but also enhances interpretability, making it a promising tool for clinical ERM management.

What Problem Does This Paper Address?

Epiretinal membranes (ERM) are a common condition, particularly in older adults, that can lead to vision loss. While Optical Coherence Tomography (OCT) is the gold standard for diagnosing ERM, accurately assessing its severity for clinical management remains a challenge. Traditional deep learning (DL) models for ERM detection often lack interpretability, making it difficult for clinicians to trust their outputs. Furthermore, many existing studies rely on data from a single OCT device, limiting the generalizability of their findings. This paper aims to address these limitations by developing a robust, interpretable, and multi-device compatible DL system for fine-grained ERM severity grading.

Methods

The core innovation of this work is the development of a two-stage deep learning system named iERM.

  • Stage One: Segmentation Model: A U-Net architecture is employed to segment specific retinal layers. This stage is crucial for capturing the subtle morphological changes associated with different ERM severity stages. The segmentation focuses on key features that are known to be important for clinical diagnosis.
  • Stage Two: Classification Model: The original OCT image and the segmentation map from Stage One are jointly fed into a classification network (initially ResNet-34 was found to be optimal). This "two-stage" approach, where segmentation informs classification, is designed to improve accuracy and provide interpretability. The segmentation map acts as an explicit representation of the features the model is focusing on, addressing the "black box" problem often associated with DL.

The authors also implemented several data processing steps to handle variations across different OCT devices, including grayscale conversion, brightness/contrast adjustments, and resizing to a uniform 224x224 resolution. Data augmentation techniques were also used to improve robustness.

Datasets

The study utilized a substantial dataset comprising 4547 OCT B-scans from nine international medical centers. This data was collected using four different commercial OCT devices: Heidelberg, Cirrus, Zeiss, and Nidek.

  • Internal Dataset: A primary dataset was collected from the Second Affiliated Hospital of Zhejiang University (ZJU dataset).
  • External Datasets: Two independent external datasets (Xian 1 and Japan) were used to rigorously test the generalizability of the iERM system.

This multi-center, multi-device approach is a significant strength, creating a more realistic benchmark than studies relying on single-source data.

Key Insights and Ideas

  • Segmentation as a Bridge to Interpretability: The most significant insight is how incorporating human-derived segmentation of key retinal features can make DL models more interpretable. By explicitly identifying and segmenting relevant anatomical structures, the model's decision-making process becomes more transparent, fostering trust among clinicians.
  • Two-Stage Approach Outperforms Single-Stage: The two-stage segmentation-then-classification architecture demonstrably improved performance over traditional single-stage classification models. This highlights the benefit of leveraging prior anatomical knowledge within the DL pipeline.
  • Clinical Relevance of Fine-Grained Grading: The study emphasizes that accurate fine-grained grading of ERM is crucial for guiding clinical management, such as referral decisions and treatment planning. iERM's ability to provide this detailed classification is a key contribution.
  • Robustness Across OCT Devices: Testing on data from multiple OCT devices and external datasets demonstrates the system's potential for real-world clinical application, where diverse imaging equipment is common.

Key Results

  • Improved Accuracy: The iERM system achieved high total accuracy scores: 82.9% on the internal dataset, 87.0% on the Xian 1 external dataset, and 79.4% on the Japanese external dataset.
  • Performance Boost: Compared to traditional single-stage DL models, iERM improved grading performance by 1-5.9%.
  • Comparable to Specialists: The performance of iERM was comparable to that of retinal specialists. For the Xian 1 dataset, iERM achieved 87.0% accuracy, while ophthalmologists averaged 87.8%. For the Japanese dataset, iERM achieved 79.4% accuracy, matching the ophthalmologists' average.
  • Segmentation Performance: The segmentation network itself showed excellent performance, with a mean Dice coefficient of 0.953 and a mean Intersection over Union (IoU) of 0.130, indicating high consistency with ground truth labels.

Limitations and Future Work

  • Dataset Imbalance: The study acknowledges that the number of images for specific ERM stages was imbalanced, which could influence performance.
  • Limited Data for Some Devices: The dataset size for OCT devices other than Heidelberg was relatively small, suggesting a need for larger-scale studies with more diverse devices.
  • Interpretability for Clinical Practice: While interpretability was enhanced, the authors note that it might still be insufficient for full clinical integration, suggesting further efforts are needed to build trust.
  • Future Directions: The authors suggest joint efforts between healthcare providers and AI developers to further improve interpretability and integrate AI systems into clinical settings. They also propose developing a user-friendly interface for patients and doctors to upload OCT reports and receive analyzed results, promoting tele-ophthalmology.

Summary updated

Abstract

Background: Epiretinal membranes (ERM) have been found to be common among individuals >50 years old. However, the severity grading assessment for ERM based on optical coherence tomography (OCT) images has remained a challenge due to lacking reliable and interpretable analysis methods. Thus, this study aimed to develop a two-stage deep learning (DL) system named iERM to provide accurate automatic grading of ERM for clinical practice. Methods: The iERM was trained based on human segmentation of key features to improve classification performance and simultaneously provide interpretability to the classification results. We developed and tested iERM using a total of 4547 OCT B-Scans of four different commercial OCT devices that were collected from nine international medical centers. Results: As per the results, the integrated network effectively improved the grading performance by 1−5.9% compared with the traditional classification DL model and achieved high accuracy scores of 82.9%, 87.0%, and 79.4% in the internal test dataset and two external test datasets, respectively. This is comparable to retinal specialists whose average accuracy scores are 87.8% and 79.4% in two external test datasets. Conclusion: This study proved to be a benchmark method to improve the performance and enhance the interpretability of the traditional DL model with the implementation of segmentation based on prior human knowledge. It may have the potential to provide precise guidance for ERM diagnosis and treatment.
BibTeX
@article{jin2023ierm,
  author = {Kai Jin and Yan Yan and Shuai Wang and Ce Yang and Menglu Chen and Xindi Liu and Hiroto Terasaki and Tun-Hang Yeo and Neha Gulab Singh and Yao Wang and Juan Ye},
  title = {{iERM: An Interpretable Deep Learning System to Classify Epiretinal Membrane for Different Optical Coherence Tomography Devices: A Multi-Center Analysis}},
  journal = {Journal of Clinical Medicine},
  year = {2023},
  doi = {10.3390/jcm12020400},
}
Figure