Identification of Control Parameters in Doubly Fed Induction Generators via Adaptive Differential Evolution

Jun Deng, Yu Wang, Yao Liu, Tianyue Zheng, Nan Xia, Ziang Li, Tong WangEnergies 2025

TL;DR

This paper introduces a novel method for identifying the crucial control parameters of Doubly Fed Induction Generators (DFIGs) used in wind turbines. By combining trajectory sensitivity analysis with an adaptive differential evolution algorithm, the method accurately identifies these "black box" parameters even during mild voltage disturbances, a significant improvement over existing techniques.

What Problem Does This Paper Address?

Wind power is rapidly becoming a cornerstone of global energy, with DFIGs being the dominant technology for wind turbine generation. However, the complex control systems within these DFIGs are often treated as "black boxes" by manufacturers, meaning their internal control parameters are proprietary and not readily available. This lack of transparency hinders detailed analysis of DFIG transient behavior and overall grid stability. Existing methods for identifying these parameters often struggle to provide accurate results during minor voltage dips, which are common in real-world grid operations. This limitation makes it difficult to build precise DFIG models for accurate system stability studies and reliable grid integration.

Methods

The paper proposes a two-pronged approach:

  1. Trajectory Sensitivity Analysis: This technique is used to assess how sensitive the DFIG's system response is to changes in each control parameter. By quantifying this sensitivity, the authors can determine the "identifiability" of each parameter and establish a prioritized sequence for their identification. Parameters with higher sensitivity are easier to identify and are tackled first.
  2. Adaptive Differential Evolution (ADE) Algorithm: This is the core of the identification process. Differential Evolution (DE) is a population-based metaheuristic optimization algorithm. The authors enhance it by introducing adaptive mechanisms for:
  3. Scaling Factor (F): Dynamically adjusting F helps balance global exploration (searching a wide range of parameter values) and local convergence (fine-tuning the solution).
  4. Crossover Rate (CR): Similarly, adapting CR helps maintain population diversity and prevent premature convergence to suboptimal solutions.
  5. Hybrid Multi-Strategy Mutation: This incorporates three different mutation strategies, allowing the algorithm to choose the most effective one at each iteration to further improve exploration and convergence.
  6. Diversity Preservation: A mechanism is included to monitor population diversity and trigger resampling if it drops too low, preventing the algorithm from getting stuck.

The discretized time-domain expressions of the DFIG's converter control loops are used to formulate a fitness function, which the ADE algorithm then optimizes to find the best parameter values.

Datasets

Not discussed in the paper. The authors used a white-box model of a DFIG built in the ADPSS 2.6/ETSDAC electromagnetic simulation software for their validation.

Key Insights and Ideas

  • Parameter Identifiability Matters: The paper highlights that not all parameters are equally easy to identify. Trajectory sensitivity provides a quantitative way to understand this and guides the identification order, leading to more efficient and accurate results.
  • Mild Disturbances are Key: The ability to identify parameters accurately even during mild voltage dips (0.9 p.u.) is a significant advancement. This makes the method much more practical for real-world applications where severe faults are less frequent than minor voltage fluctuations.
  • Adaptive Optimization is Crucial: The adaptive nature of the DE algorithm is key to its success. By dynamically adjusting its internal parameters, it can effectively navigate the complex search space of DFIG control parameters, achieving a good balance between exploration and exploitation.
  • Inner Loops First: The analysis reveals that inner-loop PI controller parameters are more sensitive and thus should be identified before outer-loop parameters, which are influenced by the inner-loop performance.

Key Results

  • The proposed method achieved high accuracy in identifying DFIG control parameters, with identification errors for most parameters controlled within 1%.
  • The method demonstrated robustness, maintaining satisfactory performance even with added 3% Gaussian noise to the measurement data and with a 10% perturbation in DFIG inductances.
  • The identification process was rapid, with convergence achieved in approximately 20 iterations.
  • The identified parameters, when substituted back into the DFIG model, produced predicted outputs that closely matched the actual outputs of the benchmark controller, validating the effectiveness of the identification.

Limitations and Future Work

  • Crowbar Protection: The current study does not incorporate Crowbar protection logic, which is often present in DFIGs and can lead to brief uncontrolled operating states during severe faults. The authors acknowledge that further investigation into scenarios involving Crowbar intervention is needed.
  • Mild Voltage Dips: While the method excels at mild voltage dips, the paper mentions that further investigation of scenarios where Crowbar protection might intervene for 2-3 cycles falls outside the scope of this study.
  • Future Work: The authors suggest that further investigation into scenarios involving Crowbar intervention will be considered in future work. The paper also implies that the framework could be extended to other types of renewable energy systems.

Summary updated

Abstract

With the increasing penetration of renewable energy generation, analysis of the transient characteristics of doubly fed induction generators, as the mainstream wind turbine configuration, is made highly significant both theoretically and practically. However, manufacturers treat the control parameters as confidential commercial secrets, rendering them a “black box”. Parameter identification is fundamental for studying transient characteristics and system stability. Existing identification methods achieve accurate results only under moderate or severe voltage dip faults. To address this limitation, this paper proposes a control parameter identification method based on the adaptive differential evolution algorithm, suitable for DFIG time-domain simulation models. This method enables accurate parameter identification even during mild voltage dips. Firstly, a trajectory sensitivity analysis is employed to evaluate the difficulty of identifying each parameter, establishing the identification sequence accordingly. Secondly, based on the control loop where each parameter resides, the time-domain expressions are discretized to formulate the fitness function. Finally, the identified control parameters are compared against their true values. The results demonstrate that the proposed identification method achieves high accuracy and robustness while maintaining a rapid identification rate.
BibTeX
@inproceedings{deng2025identification,
  author = {Jun Deng and Yu Wang and Yao Liu and Tianyue Zheng and Nan Xia and Ziang Li and Tong Wang},
  title = {{Identification of Control Parameters in Doubly Fed Induction Generators via Adaptive Differential Evolution}},
  booktitle = {Energies},
  year = {2025},
  doi = {10.3390/en18184979},
}
Figure