Hydrosomes: Optically trapped femtoliter containers for single molecule studies and microfluidics

Joseph E. Reiner, Alice Crawford, Rani Kishore, Lori S. Goldner, Michael K. Gilson, Kristian HelmersonarXiv 2005 · DOI · arXiv

Abstract

We demonstrate a novel technique for creating, manipulating, and combining femtoliter volume chemical containers. Possible uses include creating controlled chemical reactions involving small quantities of reagent, and studying the dynamics of single molecules within the containers by fluorescence imaging techniques. The containers, which we call hydrosomes, are surfactant stabilized aqueous droplets in a low index-of-refraction fluorocarbon medium. The index of refraction mismatch between the container and fluorocarbon is such that individual hydrosomes can be optically trapped by single focus laser beams, i.e. optical tweezers. Here we trap and manipulate individual hydrosomes. We demonstrate a controlled chemical reaction by the fusion of a hydrosome containing DNA segments approximately 1000 base pairs in length with a hydrosome containing YOYO-1, a DNA intercalating dye. We furthermore detect the fluorescence from single dye molecules in a hydrosome, and observe single pair fluorescence resonance energy transfer (spFRET) from Cy3-Cy5 molecules attached to a single-stranded 16mer DNA molecule.

Introduction

Studying the behavior of single molecules requires isolation and immobilization techniques that allow for long-term observation without altering the molecule's natural dynamics. Traditionally, researchers have relied on tethering molecules to glass surfaces or trapping them within porous gels. However, these environments are often chemically inhomogeneous and can introduce surface-binding artifacts that interfere with experimental results. While liposomes (lipid-membrane vesicles) offer a more biomimetic environment, they present significant operational challenges: they are difficult to load with precise reagent concentrations, require external energy (such as electric shocks) to fuse, and are prone to leakage during manipulation.

This paper introduces "hydrosomes"—surfactant-stabilized, femtoliter-sized aqueous droplets suspended in a fluorocarbon oil—as a robust alternative. These mobile containers can be individually captured, moved, and fused using optical tweezers, enabling a form of "adaptive microfluidics" where chemical environments are constructed and modified in real-time.

Methodology and Experimental Design

Hydrosome Creation and Stabilization

Hydrosomes are produced by mixing an aqueous solution containing the biological cargo with a fluorocarbon liquid (FC-77) and a surfactant (Triton X-100). Brief sonication (approximately 30 seconds) generates a population of droplets with diameters typically less than 2 μm. The surfactant is critical for stabilizing the droplets against spontaneous coalescence and preventing volume loss due to laser-induced heating.

Optical Trapping and Manipulation

The physical principle enabling the manipulation of hydrosomes is the refractive index mismatch between the aqueous interior ($n \approx 1.33$) and the fluorocarbon medium ($n \approx 1.29$). Because the droplet has a higher refractive index than its surroundings, it can be captured by a single-focus infrared laser beam (optical tweezers). Using a dual-trap configuration, the researchers can hold one hydrosome stationary while driving a second droplet into it. Unlike liposomes, hydrosomes fuse spontaneously upon contact, allowing for the instantaneous mixing of reagents.

Detection and Analysis

Fluorescence detection is performed using a modified confocal microscope equipped with avalanche photodiodes (APDs). This setup allows for high-sensitivity measurements, including the observation of step-wise photobleaching—a hallmark of single-molecule detection where the fluorescence signal drops in discrete increments as individual dye molecules are deactivated.

Key Results and Discussion

Controlled Chemical Reactions

To demonstrate the utility of hydrosomes for micro-chemistry, the authors performed a controlled fusion experiment. One hydrosome containing DNA segments (1000 bp) was fused with another containing YOYO-1, a DNA intercalating dye. Upon fusion, the researchers observed a rapid increase in fluorescence as the dye molecules bound to the DNA, successfully demonstrating a femtoliter-scale chemical reactor.

Single-Molecule Resolution and FRET

The platform's sensitivity was validated through several single-molecule benchmarks:

  • Counting Molecules: By observing Sulforhodamine-B (SRB) within trapped droplets, the team successfully resolved the fluorescence of one, two, and three individual molecules.
  • spFRET: The researchers captured single-pair Fluorescence Resonance Energy Transfer (spFRET) trajectories from a 16mer ssDNA molecule labeled with Cy3 and Cy5. This confirms that hydrosomes can resolve sub-nanometer structural changes in real-time without surface interference.
  • Biological Viability: A major concern was whether the sonication process would denature proteins. Testing with Red Fluorescent Protein (RFP) showed that over 50% of the proteins remained functional, proving the method is compatible with fragile biological samples.

Adaptive Microfluidics

Unlike traditional microfluidic chips with fixed channels, hydrosomes allow for a dynamic experimental architecture. The "channels" are defined by the movement of the optical traps, allowing researchers to change the experiment mid-stream based on real-time observations. This flexibility represents a significant shift toward more versatile "lab-on-a-chip" technologies.

Limitations and Future Directions

Despite the advantages, the system faces challenges regarding photobleaching. Oxygen is highly soluble in fluorocarbons, which can accelerate the degradation of fluorescent dyes. While oxygen scavenging systems can mitigate this, further refinement is needed for long-duration studies. Additionally, precise metrology of sub-micron droplets remains difficult; the authors suggest that incorporating a secondary position-detection laser could improve volume measurements, which is essential for calculating exact chemical concentrations. Finally, researchers must remain mindful of potential interface partitioning, where certain molecules might preferentially migrate to the water-oil boundary.

Conclusion

Hydrosomes provide a powerful new tool for single-molecule biophysics and microfluidics. By combining the isolation of femtoliter containers with the precision of optical manipulation, this technique bypasses the limitations of surface-tethering and the complexities of liposome handling, opening new pathways for studying molecular dynamics in a controlled, three-dimensional environment.

Summary updated

Abstract

We demonstrate a novel technique for creating, manipulating, and combining femtoliter volume chemical containers. Possible uses include creating controlled chemical reactions involving small quantities of reagent, and studying the dynamics of single molecules within the containers by fluorescence imaging techniques. The containers, which we call hydrosomes, are surfactant stabilized aqueous droplets in a low index-of-refraction fluorocarbon medium. The index of refraction mismatch between the container and fluorocarbon is such that individual hydrosomes can be optically trapped by single focus laser beams, i.e. optical tweezers. Here we trap and manipulate individual hydrosomes. We demonstrate a controlled chemical reaction by the fusion of a hydrosome containing DNA segments approximately 1000 base pairs in length with a hydrosome containing YOYO-1, a DNA intercalating dye. We furthermore detect the fluorescence from single dye molecules in a hydrosome, and observe single pair fluorescence resonance energy transfer (spFRET) from Cy3-Cy5 molecules attached to a single-stranded 16mer DNA molecule.
BibTeX
@misc{reiner2005hydrosomes,
  author = {Joseph E. Reiner and Alice Crawford and Rani Kishore and Lori S. Goldner and Michael K. Gilson and Kristian Helmerson},
  title = {{Hydrosomes: Optically trapped femtoliter containers for single molecule studies and microfluidics}},
  year = {2005},
  eprint = {physics/0510196},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/physics/0510196},
}

Loading related content...

Figure