[High-throughput sequencing in identifying somatic hypermutation in immunoglobulin heavy chain variable regions with complex clonal backgrounds].

Minjie Gao, Rong Wei, Y Liu, X J Huang, Sen Yang, Xiang‐Yu Zhao2025 · DOI

TL;DR

This study highlights the superiority of Next-Generation Sequencing (NGS) over traditional Sanger sequencing for analyzing immunoglobulin heavy chain (IGHV) somatic hypermutation (SHM) in complex clonal backgrounds, particularly in lymphoid malignancies like Chronic Lymphocytic Leukemia (CLL). NGS offers greater sensitivity and accuracy in identifying and quantifying subclonal populations, leading to more precise diagnoses and prognoses.

What Problem Does This Paper Address?

In the study of lymphoid malignancies, particularly Chronic Lymphocytic Leukemia (CLL), understanding the somatic hypermutation (SHM) status of immunoglobulin heavy chain (IGHV) genes is crucial for prognosis and treatment stratification. SHM is a process where B cells introduce mutations into their IGHV genes to improve antibody binding affinity. Different mutation statuses (mutated vs. unmutated) correlate with distinct clinical outcomes. Traditionally, Sanger sequencing has been the gold standard for this analysis. However, Sanger sequencing struggles with complex scenarios involving multiple B cell clones (polyclonal or biclonal backgrounds) and cannot accurately quantify the relative abundance of these clones. This limitation can lead to misinterpretations of the mutational status and hinder precise risk stratification. This paper aims to address this by comparing the performance of NGS, a more advanced sequencing technology, against Sanger sequencing in these complex clonal settings.

Methods

The researchers conducted a retrospective analysis of 53 patient samples from Peking University People's Hospital. These samples were initially analyzed using Sanger sequencing for IGHV SHM status. Forty-three of these samples were classified as "non-monoclonal" by Sanger, and ten were classified as "monoclonal." All 53 samples were then re-analyzed using Next-Generation Sequencing (NGS) to assess IGHV SHM.

The core of the methodology involved a systematic comparison of the results obtained from both techniques. For cases where the results differed (discordant cases), the researchers performed an in-depth attribution analysis. This analysis focused on identifying the key factors contributing to the discrepancies, specifically examining:

  • Clonal abundance quantification: How accurately each method could measure the proportion of different B cell clones.
  • Primer design differences: The impact of the specific DNA primers used by each method to amplify the IGHV genes.
  • Interpretation criteria: The established thresholds and rules used to define clonality and mutational status.

For NGS data analysis, they defined specific criteria for clonality: a single clone was identified if its reads constituted at least 2.5% of the total detected fragments. Biclonality or polyclonality was defined based on the proportion of the top reads and their relative abundance. IGHV mutations were identified by comparing sequences to germline IGHV genes, with a similarity of less than 98% indicating a mutation.

Datasets

The study utilized a dataset of 53 patient samples collected retrospectively from Peking University People's Hospital between 2016 and 2021. These samples were from patients diagnosed with lymphoid malignancies, including:

  • Chronic Lymphocytic Leukemia (CLL): 35 samples (66.0%)
  • Diffuse Large B-cell Lymphoma: 9 samples (17.0%)
  • Follicular Lymphoma: 3 samples (5.7%)
  • Mantle Cell Lymphoma: 3 samples (5.7%)
  • Other types: 3 samples (5.7%)

The samples comprised 43 cases initially classified as non-monoclonal by Sanger sequencing and 10 cases classified as monoclonal. The dataset was used for comparative analysis between Sanger and NGS methods. No new benchmark datasets were introduced.

Key Insights and Ideas

  • NGS excels in complex clonal landscapes: The most significant insight is that NGS demonstrably outperforms Sanger sequencing when dealing with samples containing multiple B cell clones. This is critical because many lymphoid malignancies, especially CLL, can exhibit such complexity.
  • Subclonal detection is key: NGS's ability to detect and quantify "subclonal" populations (smaller groups of cells within a larger clone) is a major advantage. Sanger often misses these, leading to an incomplete picture.
  • Primer design matters: Differences in the primers used for amplification between Sanger and NGS can influence the detected sequences and, consequently, the results. This is an important technical consideration for interpreting discrepancies.
  • Interpretation standards are evolving: The study implicitly highlights the need for standardized interpretation criteria for NGS data, especially concerning the definition of subclonal thresholds, as there isn't a universally agreed-upon standard.
  • Clinical implications for CLL: The findings have direct implications for the clinical management of CLL, suggesting that NGS can provide a more accurate molecular basis for diagnosis and prognosis, potentially leading to better-tailored treatment strategies.

Key Results

  • Out of 43 samples initially classified as non-monoclonal by Sanger, NGS identified 23 as biclonal or polyclonal, 17 as monoclonal, and 3 as having no detectable clonality. This indicates that Sanger missed significant clonal complexity in a substantial portion of cases.
  • Among the 10 samples identified as monoclonal by Sanger, NGS detected biclonality in 2 cases and identified markedly different IGHV rearrangement types in 4 cases.
  • While minor differences in the percentage of SHM were observed between the two methods, these did not significantly alter the overall determination of mutational status (mutated vs. unmutated).
  • NGS demonstrated superior sensitivity and accuracy in quantifying clonal proportions and identifying subclonal components compared to Sanger sequencing.

Limitations and Future Work

Limitations:

  • Retrospective design: The study was retrospective, meaning it analyzed existing data rather than prospectively collecting new data. This can sometimes limit the ability to establish causality.
  • Sample size: While 53 samples were analyzed, a larger cohort would provide even stronger statistical power.
  • Interpretation criteria for sub-clones: The authors acknowledge that there isn't a universally accepted definition for subclonal thresholds, and they relied on a previously published method. This highlights a need for standardization.
  • Potential for missed clonality: While NGS is superior, the authors note that discrepancies still exist, suggesting that even NGS might not capture every single minute subclone in all scenarios.

Future Work:

  • Larger, prospective studies: The authors advocate for more extensive, systematic studies with larger sample sizes and long-term follow-up to further validate the clinical utility of NGS in various scenarios.
  • Standardized interpretation guidelines: There is a clear need to develop unified interpretation standards and practical guidelines for NGS analysis of IGHV SHM. This will improve the comparability and reproducibility of results across different laboratories and clinical centers.
  • Exploring complex IGHV rearrangements: Further research into rare or complex IGHV rearrangement patterns is warranted to refine diagnostic and prognostic models.

Summary updated

Abstract

<b>Objective:</b> To compare the performance of next-generation sequencing (NGS) and Sanger sequencing in investigating somatic hypermutation (SHM) status of immunoglobulin heavy chain variable region (IGHV) genes. It specifically focuses on identifying key factors contributing to discrepancies between the two methods, particularly under complex clonal backgrounds, to inform optimized strategies for clinical application. <b>Methods:</b> This retrospective analysis included 53 samples, comprising 43 identified as non-monoclonal and 10 as monoclonal using Sanger sequencing. All samples were further analyzed using NGS to assess IGHV SHM. The two methods were used for systematic comparison. For discordant cases, in-depth attribution analysis was conducted, considering factors, including clonal abundance quantification, differences in primer design, and interpretation criteria. <b>Results:</b> Among the 53 patients who underwent both Sanger and NGS testing, 36 were male and 17 were female, with a median age of 64 years (range: 33-88). Diagnoses included chronic lymphocytic leukemia (CLL) in 35 (66.0% ), diffuse large B-cell lymphoma in 9 (17.0% ), follicular lymphoma in 3 (5.7% ), mantle cell lymphoma in 3 (5.7% ), and other types in 3 (5.7% ) cases. In the 43 cases with non-monoclonal profiles using Sanger sequencing, NGS revealed 23 cases as biclonal or polyclonal, 17 as monoclonal, and 3 with no detectable clonality. The primary discrepancies between the two methods involved variations in clonality assessment, IGHV gene rearrangement types, and mutation rates. Among the 10 cases identified as monoclonal using Sanger sequencing, NGS detected biclonality and markedly different IGHV rearrangement types in 2 and 4 cases, respectively. Minor differences were observed in SHM percentage between the two methods; however, these did not substantially affect the overall determination of mutational status. <b>Conclusion:</b> Compared with Sanger sequencing, NGS exhibits superior performance in assessing IGHV SHM status under complex clonal conditions. It provides greater sensitivity and accuracy in detecting subclonal components and quantifying clonal proportions, thereby providing a more precise molecular basis for diagnosing and prognostically assessing lymphoid malignancies, including CLL.
BibTeX
@misc{gao2025high,
  author = {Minjie Gao and Rong Wei and Y Liu and X J Huang and Sen Yang and Xiang‐Yu Zhao},
  title = {{[High-throughput sequencing in identifying somatic hypermutation in immunoglobulin heavy chain variable regions with complex clonal backgrounds].}},
  year = {2025},
  doi = {10.3760/cma.j.cn121090-20241016-00394},
}
Figure