Abstract
Ten resonant wavelengths could be multiplexed successfully by writing long-period gratings (LPGs) with different pitches using a CO2 laser. A preliminary distributed temperature monitoring experiment was conducted, and it was estimated that separation between 2 adjacent resonant peaks was 13.2nm, even when the temperature difference between 2 adjacent LPGs was 150°C. This separation is large enough to distinguish the resonant wavelengths individually. The results clarified that this multiplexing approach enables the LPFG to detect a local high temperature caused by an abnormal reaction inside large-scale plants.
Introduction
Monitoring the internal health of large-scale infrastructure, such as nuclear power generators or chemical reactors, requires sensors capable of detecting abnormal thermal reactions at specific locations. While Brillouin scattering techniques are often used for distributed fiber sensing, they are complex and expensive, requiring sophisticated electronics to analyze weak backscattered light.
Long-Period Fiber Gratings (LPFGs) offer a simpler, more robust alternative. As passive components, they do not require electricity at the sensing site and remain stable under electromagnetic interference. However, the primary challenge lies in multiplexing: integrating multiple sensors onto a single fiber while ensuring their signals remain distinguishable during significant temperature fluctuations.
System Design and Fabrication
The researchers developed a distributed temperature sensor by multiplexing 10 LPFGs onto a single-mode fiber using a $CO_2$ laser. Each sensor is assigned a unique "address" in the optical spectrum by varying the grating pitch ($p_g$) from 0.478 mm to 0.610 mm.
To ensure strong signals for larger pitches ($> 0.52$ mm), a "two-time scanning method" was employed. In this process, the laser carves the grating twice with a 0.1 mm offset, significantly enhancing the resulting loss peaks. The overall system architecture, shown below, utilizes a White Light Source (WLS) and an Optical Spectrum Analyzer (OSA) connected to a central server for remote monitoring.
Experimental Results and Discussion
The fabrication process successfully spread 10 resonant peaks across a wide spectral range (approximately 1170 nm to 1570 nm). This wide spacing is critical for preventing signal overlap when thermal shifts occur.
Temperature Sensitivity
Each of the 10 sensors demonstrated a highly linear relationship between temperature and wavelength shift. Sensitivity coefficients ($B$ values) ranged from 0.043 to 0.109 nm/$^\circ C$, varying with the grating pitch.
"Hot Spot" Detection
A key finding was the system's ability to maintain a safety margin between signals. Even with a $150^\circ C$ temperature difference between adjacent sensors (e.g., one at $170^\circ C$ and another at $20^\circ C$), the peaks remained separated by at least 13.2 nm. This separation is sufficient for automated systems to distinguish individual "hot spots" without ambiguity.
Multiplexing Performance
- Peak Separation: At uniform room temperature, adjacent resonant peaks were separated by 21 nm to 89 nm.
- Signal Integrity: The total loss spectrum of the multiplexed fiber closely matched the sum of individual LPG losses, indicating minimal interference between sensors.
- High-Temperature Stability: In distributed tests, a specific sensor (LPG 6) heated to $170^\circ C$ showed an 8.5 nm shift, while neighboring sensors remained unaffected.
Conclusion
This study demonstrates a cost-effective and robust method for distributed temperature sensing in industrial environments. By multiplexing 10 LPFGs with varying pitches, the system can reliably detect local high-temperature anomalies. Future work may involve combining grating pitch variations with fiber thinning techniques to further increase sensor density and quantity on a single fiber.
Summary updated